KONG -Y
NameDescriptionContent
Location:
product
IS200TCATH1A Analog terminal board
❤ Add to collection

IS200TCATH1A Analog terminal board

IS200TCATH1A
U.S.$96150.00
U.S.$75550.00
U.S.$71772.50
U.S.$70261.50
Weight:3.550KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
IS200TCATH1A

Part Number IS200TCATH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockIS200TCATH1A is a core analog terminal board developed by GE. 

It is a part of Mark VIe control system. The Core Analog terminal board serves as an augmentation to the I/O terminal capacity of the PCAA module. 

It takes on the responsibility of managing input signals, which are then distributed to either a single PCAA module or three of them. This encompassing functionality involves handling various input types, such as twelve seismic inputs, twelve LVDT inputs, twenty-four 4-20 mA inputs, and two magnetic pulse rate inputs. Ensuring the efficiency of the system, a distinct 24 V dc power source is allocated for all twenty-four 4-20 mA inputs. This power allocation is shared between the TCAT and an adjacent JGPA board, with half of the inputs being managed by each. 

This strategic power distribution optimizes the utilization of resources. Features TCAT generates three 4-20 mA voted signals, contributing to the precision of the system's output functionality. To facilitate these connections, the TCAT features a comprehensive array of field wire terminal points, with 120 pluggable Euro-style box terminals ensuring secure connections. Terminal points are organized into three groupings: one set of 48 terminals, another set of 24, and a final set of 48, enhancing the organization and accessibility of the system. Integrated JGPA, situated adjacently to the terminals, supplements the system's capabilities. It provides an additional twelve 24 V dc outputs tailored for 4-20 mA devices, as well as dedicated terminals for shielding wires. The power supply to the JGPA emanates from TCAT connectors P3 or P4, employing a diode-or arrangement that combines power from the connected PCAA modules. This setup ensures reliable power distribution and stability within the system. The terminal board's multifaceted role in the system includes enhancing I/O terminal capacity, managing diverse input signals, and providing a streamlined mechanism for generating output signals. This strategic allocation of power, comprehensive field wire terminal points, and collaboration with the adjacent JGPA board all contribute to the overall efficiency, reliability, and precision of the system's analog functionalities. 

 Characteristics Twelve seismic, twelve LVDT, twenty four 4-20 mA, and two magnetic pulse rate inputs are available. Each of the twenty-four 4-20 mA inputs has its own 24 V dc power source, with half on TCAT and the other half on an adjacent JGPA board. TCAT outputs are made up of three voted signals ranging from 4 to 20 mA. 120 pluggable Euro-style box terminals provide field wire terminal points. Terminal grouping consists of 48 terminals, 24 terminals, and 48 terminals again. A JGPA board next to the TCAT field terminals adds twelve more 24 V dc outputs for 4-20 mA devices and shield wire terminals. Connector P3 or P4 supplies power to JGPA and acts as a diode-or for power from connected PCAA modules. 

Terminal board is connected to one or more PCAA modules via pairs of 68-pin cables. PR1 and PR2 are routed to a PCAA that is linked to the R IONet. PS1 and PS2 are connected to a PCAA via the S IONet. PT1 and PT2 connect to a PCAA that is linked to T IONet. On each cable connection, it generates an electronic ID. Cables are always used in pairs, and the electronic ID is used by PCAA to ensure that the correct TCAT cables are in place. Installation The module is attached to a metal back base via an underlying insulating plastic carrier. Screws are located at the top and bottom of the field terminals, with a third screw in the board's center. It is attached to a metal back base via an underlying insulating plastic carrier. Screws are located at the top and bottom of the field terminals, with a third screw in the board's center. Wiring The TCAT terminal board has 120 Euro-style box terminals that can be plugged in. A JGPA board, which mounts next to the TCAT terminal board, provides 48 shield termination points as well as twelve 24 V dc output terminals for 4-20 mA transmitters. 

 Operation The module distributes input signals to one or more PCAA modules. To ensure reliability in redundant applications, high reliability passive circuits are used. Board accepts 28 V dc power from PCAA modules that are connected. The power sources are then diode-ored to obtain redundant power input for the 24 V dc outputs. 

TCAT's 24 V outputs each have their own voltage regulator with thermal shutdown for branch circuit protection. Product Attributes Input: Twenty-four signals in the range of 4-20 mA. A total of twelve seismic signals. Twelve LVDT windings are incorporated as inputs. Additionally, two magnetic pulse rate flow signals are accepted. Output: Three analog outputs with hardware voting, operating in the 4-20 mA range. A set of twelve outputs, each capable of 24 V dc, with the capacity to handle 25 mA current. An auxiliary set of twelve 24 V dc outputs on the JGPA, also with a 25 mA capacity. Power Supply Voltage: A power supply voltage of 28 V dc, with a tolerance of 5%, is sourced from either one or more PCAA modules. Another power supply source is 15 V dc, also derived from one or more PCAA modules. Both of these power supply inputs are routed through the cabling linking the PCAA and TCAT components. 

 Pulse Rate Input: For proper measurement, the minimum signal strength required is 33 mVpk at a frequency of 2 Hz. Similarly, the minimum signal strength required for accurate measurement at a frequency of 12 kHz is 827 mVpk.CA TMR TB

  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930 presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • Configuration for AMS 6500 Protection Monitors
  • EMERSON DeltaV™ M-series Traditional I/O
  • EMERSON DeltaV™ SQ Controller
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • ABB Ethernet Modules EI 802F
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • Control product - Soft starter PST/PSTB (Intelligent Type) ABB
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives