Description
IS200TCATH1A

Part Number IS200TCATH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockIS200TCATH1A is a core analog terminal board developed by GE. 

It is a part of Mark VIe control system. The Core Analog terminal board serves as an augmentation to the I/O terminal capacity of the PCAA module. 

It takes on the responsibility of managing input signals, which are then distributed to either a single PCAA module or three of them. This encompassing functionality involves handling various input types, such as twelve seismic inputs, twelve LVDT inputs, twenty-four 4-20 mA inputs, and two magnetic pulse rate inputs. Ensuring the efficiency of the system, a distinct 24 V dc power source is allocated for all twenty-four 4-20 mA inputs. This power allocation is shared between the TCAT and an adjacent JGPA board, with half of the inputs being managed by each. 

This strategic power distribution optimizes the utilization of resources. Features TCAT generates three 4-20 mA voted signals, contributing to the precision of the system's output functionality. To facilitate these connections, the TCAT features a comprehensive array of field wire terminal points, with 120 pluggable Euro-style box terminals ensuring secure connections. Terminal points are organized into three groupings: one set of 48 terminals, another set of 24, and a final set of 48, enhancing the organization and accessibility of the system. Integrated JGPA, situated adjacently to the terminals, supplements the system's capabilities. It provides an additional twelve 24 V dc outputs tailored for 4-20 mA devices, as well as dedicated terminals for shielding wires. The power supply to the JGPA emanates from TCAT connectors P3 or P4, employing a diode-or arrangement that combines power from the connected PCAA modules. This setup ensures reliable power distribution and stability within the system. The terminal board's multifaceted role in the system includes enhancing I/O terminal capacity, managing diverse input signals, and providing a streamlined mechanism for generating output signals. This strategic allocation of power, comprehensive field wire terminal points, and collaboration with the adjacent JGPA board all contribute to the overall efficiency, reliability, and precision of the system's analog functionalities. 

 Characteristics Twelve seismic, twelve LVDT, twenty four 4-20 mA, and two magnetic pulse rate inputs are available. Each of the twenty-four 4-20 mA inputs has its own 24 V dc power source, with half on TCAT and the other half on an adjacent JGPA board. TCAT outputs are made up of three voted signals ranging from 4 to 20 mA. 120 pluggable Euro-style box terminals provide field wire terminal points. Terminal grouping consists of 48 terminals, 24 terminals, and 48 terminals again. A JGPA board next to the TCAT field terminals adds twelve more 24 V dc outputs for 4-20 mA devices and shield wire terminals. Connector P3 or P4 supplies power to JGPA and acts as a diode-or for power from connected PCAA modules. 

Terminal board is connected to one or more PCAA modules via pairs of 68-pin cables. PR1 and PR2 are routed to a PCAA that is linked to the R IONet. PS1 and PS2 are connected to a PCAA via the S IONet. PT1 and PT2 connect to a PCAA that is linked to T IONet. On each cable connection, it generates an electronic ID. Cables are always used in pairs, and the electronic ID is used by PCAA to ensure that the correct TCAT cables are in place. Installation The module is attached to a metal back base via an underlying insulating plastic carrier. Screws are located at the top and bottom of the field terminals, with a third screw in the board's center. It is attached to a metal back base via an underlying insulating plastic carrier. Screws are located at the top and bottom of the field terminals, with a third screw in the board's center. Wiring The TCAT terminal board has 120 Euro-style box terminals that can be plugged in. A JGPA board, which mounts next to the TCAT terminal board, provides 48 shield termination points as well as twelve 24 V dc output terminals for 4-20 mA transmitters. 

 Operation The module distributes input signals to one or more PCAA modules. To ensure reliability in redundant applications, high reliability passive circuits are used. Board accepts 28 V dc power from PCAA modules that are connected. The power sources are then diode-ored to obtain redundant power input for the 24 V dc outputs. 

TCAT's 24 V outputs each have their own voltage regulator with thermal shutdown for branch circuit protection. Product Attributes Input: Twenty-four signals in the range of 4-20 mA. A total of twelve seismic signals. Twelve LVDT windings are incorporated as inputs. Additionally, two magnetic pulse rate flow signals are accepted. Output: Three analog outputs with hardware voting, operating in the 4-20 mA range. A set of twelve outputs, each capable of 24 V dc, with the capacity to handle 25 mA current. An auxiliary set of twelve 24 V dc outputs on the JGPA, also with a 25 mA capacity. Power Supply Voltage: A power supply voltage of 28 V dc, with a tolerance of 5%, is sourced from either one or more PCAA modules. Another power supply source is 15 V dc, also derived from one or more PCAA modules. Both of these power supply inputs are routed through the cabling linking the PCAA and TCAT components. 

 Pulse Rate Input: For proper measurement, the minimum signal strength required is 33 mVpk at a frequency of 2 Hz. Similarly, the minimum signal strength required for accurate measurement at a frequency of 12 kHz is 827 mVpk.CA TMR TB

  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • Configuration for AMS 6500 Protection Monitors
  • EMERSON DeltaV™ M-series Traditional I/O
  • EMERSON DeltaV™ SQ Controller
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • ABB Ethernet Modules EI 802F
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • Control product - Soft starter PST/PSTB (Intelligent Type) ABB
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives
  • GE MiCOM P40U Connect MiCOM P40 IEDs to PCs with USB ports
  • Reason RT431 GPS Precision-Time Clock GE
  • GE Reason RT430 GNSS Precision-Time Clocks
  • GE Reason H49 PRP/HSR Redbox Switch
  • GE Reason S20 Managed Ethernet Switches
  • GE Gridcom DIP.net
  • Central Control Station at Jaenschwalde mineLausitzer Braunkohle AG, Germany 2000
  • ABB Ability™ System 800xA Advant® Master S400 I/O to S800 I/O Evolution
  • ABB with Advant Controller 400 series
  • Advant™Automation with MOD 300™ Software
  • Bently 2300/20 and 2300/25 2300 Vibration Monitors
  • ABB NGC8206 Natural Gas Chromatograph Dual Unit
  • MOTOROLA MVME2400 TM VME Processor Modules
  • 5320 Series Foxboro DCS Control Network Ethernet Equipment
  • ExtremeSwitching™ 5420 Series
  • WOODWARD EGCP-3 Engine Generator Control Package LS (Load Sharing)
  • 5520 Series Universal Edge/Aggregation-Switch Platform
  • X440-G2 Series
  • EMERSON FloBoss™ S600 Flow Manager Specification Sheet
  • KONGSBERG RAIV400 Remote Analogue Input, Voltage
  • RMP420-Remote Multipurpose Input/Output Kongsberg
  • 610 serie ABB Feeder Protection REF610 Product Guide
  • Triconex 3351S2 Controller Features
  • HBRF Megamax – Emax2 Air Circuit Breaker ABB
  • ABB MEASUREMENT & ANALYTICS | DATA SHEET LS4000 Diode laser analyzer
  • Pressductor Pillowblock Load Cells Vertical Measuring PFCL 201 User manual
  • PARKER BFR5K Series
  • AC 900F controller ABB
  • Uniop ePAD05 and ePAD06 Technical description
  • Hitachi ABB Communication Unit 560CMR02
  • MOTOROLA MVME5500 Series VME Single-Board Computer
  • ABB Symphony Plus SD Series HPC800 controller
  • ABB AC800M Controller Hardware System
  • ABB AC800M PROFIBUS DP Installation System
  • ABB Freelance 800F AC800F Control systems
  • ABB Compact control system replaces PLC AC700F
  • abb Triguard SC300E 3BNP004720R101 TMR Safety Products
  • ABB Distributed busbar protection REB500
  • ABB Advant Controller 400 series
  • ABB MEASUREMENT & ANALYTICS | PRODUCT GUIDE
  • PACIFIC SCIENTIFIC PC800 PC832 PC830 Series Digital Brushless Servo Drive
  • PSS41S-3FDCTSAA Triconex DCS System Access Application Driver for Field Device Controller 280
  • Alstom controller of ICP232 029.359325
  • DEIF DU-2/MKIII Paralleling And Protection Unit General information
  • ABB 3ADT220134R0001 SDCS-COM-81 board 10MBd
  • ABB 3BHB006338R0002 UNS 0881a-P,V2:GDI PCB assembled *PB
  • ABB GRID BREAKER UNIT GBU72 3BHE055094R0002 / 3BHE031197R0001 / 3BHB030310R0001
  • ABB PCS6000 PRODUCT FAMLIY
  • ALSTOM SPU232.2 controller UNIT 029.366 817 029366817 SPU2322
  • ABB AO2000-LS25 Operator’s Manual 41/24-109 EN Rev. 3
  • Alstom EPSD-0603 series Circuit board redundancy architecture
  • ABB GJR2390200R1411 83SR04R1411 Control Module Universal
  • GE Digital Energy Hydran 201Ti Mark IV Essential DGA monitoring
  • Bender ISOMETER®IRDH275 IRDH275B
  • ABB 3BSE017235R1 PXAH 401 Operator Unit
  • HIMax-TECHNICALFACTS
  • Power supply CP-E 24/1.25 ABB
  • ABB NSIN0070-5 (IP23) 3ABD00024914
  • ABB 1VCR000993G0002 PCB card
  • ABB 2CSG524000R2021 TMD-T4/96 Temperature control unit
  • 3BHE014135R0011 UAD149A0011 ABB AC800PEC series
  • Alstom CT94360/01 signal regulator
  • MISP2-2W-T00-1000 GE Measurement & Control Solutions
  • DEIF AGC150 independent generator controller
  • DEIF AGC-4 10102264.10 Advanced generator set controller
  • ABB Plantguard Communications P8151B P8110B
  • ABB Plantguard series P8403 Digital input module
  • ABB 3BHE041343R0102 PCD530A102 Comm. Contr. & Meas. (CCM)
  • ABB P8431 TMR analog input module
  • ABB P129740-002 SIO Assembly,Smart Weight,Interface,Pre-