KONG -Y
NameDescriptionContent
Location:
product
IS200TDBSH4A Contact input/output terminal board
❤ Add to collection

IS200TDBSH4A Contact input/output terminal board

IS200TDBSH4A
U.S.$26150.00
U.S.$18025.00
U.S.$17123.75
U.S.$16763.25
Weight:0.750KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
IS200TDBSH4A

IS200TDBSH4A Contact input/output terminal board

Part Number IS200TDBSH4A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS200TDBSH4A is a contact input / output terminal board developed by GE. It is a part of the Mark VIe control system. The TDBS board is a versatile component engineered to facilitate contact input and output operations within industrial systems. Designed for seamless integration, it offers flexibility in mounting options and accommodates various voltage requirements. Contact Inputs The board features a robust design capable of accepting 24 group isolated contact inputs. These inputs are compatible with a nominal voltage of 24, 48, or 125 V DC, sourced externally. Each input is meticulously engineered to ensure reliability and longevity in demanding industrial environments. 

Voltage Compatibility: The board's contact inputs are adaptable to different voltage configurations, providing versatility to suit diverse application requirements. Whether operating at 24, 48, or Related models

DS200SHVMG1AFE

IC660ELB912

IS230TVBAH2A125 V DC, the board ensures consistent performance and compatibility with existing power systems. 

Noise Suppression: To safeguard against potential disruptions, such as surge and high-frequency noise, the contact inputs are equipped with robust noise suppression mechanisms. This feature enhances system stability and reliability by filtering out unwanted electrical disturbances, ensuring uninterrupted operation. Relay Outputs In addition to contact inputs, the board boasts 12 form-C relay outputs, augmenting its functionality in controlling external devices or processes. These relay outputs offer versatile switching capabilities, allowing for precise control and automation of industrial operations. 

Expansion Options: To further extend its relay functions, the TDBS board is designed to accommodate different option cards. These cards provide additional relay channels or specialized functionalities, enhancing the board's adaptability to specific application requirements. 

Flexibility in Configuration: The ability to incorporate option cards empowers users to tailor the board to suit their unique needs. Whether expanding relay capacity or integrating specialized features, this flexibility ensures optimal performance and scalability in diverse industrial settings. Mounting Options It offers versatility in mounting, supporting both DIN-rail and flat mounting configurations. This versatility facilitates seamless integration into various control panels or equipment enclosures, optimizing space utilization and installation efficiency. 

Installation Mounting Options: The board, along with a plastic insulator, can be mounted on a sheet metal carrier, which in turn mounts on a DIN rail. Alternatively, it can be mounted on a sheet metal assembly that bolts directly into a cabinet. These mounting options provide flexibility in installation, catering to different enclosure configurations and space constraints. Terminal Block Connections: Two sets of 48-point terminal blocks, typically utilizing 18 AWG wires, facilitate the connections for relay and contact input circuits. The upper set of terminals, labeled TB1, is dedicated to the relay portion of the board, while the lower set, labeled TB2, is for the contact input circuits. The screw assignments for these terminal blocks mirror those found on the SRLY relay board and the STCI contact input terminal board, ensuring consistency in wiring practices. 

Shield Termination: To maintain proper electromagnetic compatibility (EMC) and prevent interference, shields should be terminated on a separate bracket. This separation helps to minimize signal disturbances and ensures reliable operation and connected devices. Relay Option Board Integration: If additional relay functionality is required, a relay option board can be installed by plugging it onto connectors JW1 and JW2 on the TDBS board. The option board is held securely in place by the force of the connectors. External power, if needed, can be wired to a connector provided on the option board. 

Relay Terminal Functions (TB1): The following table delineates the function of each terminal point on the TB1 set in relation to the presence of an option board: NC (Normally Closed): Represents the normally closed contact of a form C relay. COM (Common): Denotes the common point of a form C relay contact. NO (Normally Open): Indicates the normally open contact of a form C relay. 

SOL (Solenoid Return Circuit): Provides the return circuit path for a solenoid powered by the relay board. VSENSE (Voltage Sense): Serves as the input to a voltage sensor that monitors voltage between VSENSE and COM. RETURN: Establishes the return power path for devices powered by the WROG option, ensuring proper functionality and safety. Configuration TDBS Terminal Board: The terminal board doesn't feature any jumpers or hardware settings. Its configuration relies solely on external connections and the use of option boards. 

WROBH1 Option Board: Option board WROBH1 comes equipped with six jumpers utilized for applying or removing power from a relay. By default, all six jumpers are installed on the board. Removing a jumper from the board indicates the relay is to be used as dry contacts, and power distribution isn't required. 

WROFH1 Option Board: There are no jumpers associated with the WROFH1 option board. 

The inclusion or exclusion of a series fuse for each relay depends on the terminal point used as the relay common. 

The associated WROF fuse for each relay can be removed if direct use of the fuse voltage sensing circuit as a voltage detector is preferred. 

WROGH1 Option Board: Similar to the WROFH1 board, there are no jumpers associated with the WROGH1 option board. For each relay, the corresponding fuse may be removed if the relay is intended for providing dry contacts.T DISCRETE SIMPLEX TEST

IS215VCMIH2BB IS200VCMIH2BCC

IS210MACCH1AGG

SR489-P5-LO-A20-E

MVR1600-4601

D20 EME 2400-21004

IC697MDL350

8101-HI-TX-02

IC698PSA100

IC698RMX016-ED

IC660BBD025

531X303MCPARG1

DS200FSAAG1ABA



  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930 presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • Configuration for AMS 6500 Protection Monitors
  • EMERSON DeltaV™ M-series Traditional I/O
  • EMERSON DeltaV™ SQ Controller
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • ABB Ethernet Modules EI 802F
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • Control product - Soft starter PST/PSTB (Intelligent Type) ABB
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives