Description
IS200TDBSH4A

IS200TDBSH4A Contact input/output terminal board

Part Number IS200TDBSH4A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS200TDBSH4A is a contact input / output terminal board developed by GE. It is a part of the Mark VIe control system. The TDBS board is a versatile component engineered to facilitate contact input and output operations within industrial systems. Designed for seamless integration, it offers flexibility in mounting options and accommodates various voltage requirements. Contact Inputs The board features a robust design capable of accepting 24 group isolated contact inputs. These inputs are compatible with a nominal voltage of 24, 48, or 125 V DC, sourced externally. Each input is meticulously engineered to ensure reliability and longevity in demanding industrial environments. 

Voltage Compatibility: The board's contact inputs are adaptable to different voltage configurations, providing versatility to suit diverse application requirements. Whether operating at 24, 48, or Related models

DS200SHVMG1AFE

IC660ELB912

IS230TVBAH2A125 V DC, the board ensures consistent performance and compatibility with existing power systems. 

Noise Suppression: To safeguard against potential disruptions, such as surge and high-frequency noise, the contact inputs are equipped with robust noise suppression mechanisms. This feature enhances system stability and reliability by filtering out unwanted electrical disturbances, ensuring uninterrupted operation. Relay Outputs In addition to contact inputs, the board boasts 12 form-C relay outputs, augmenting its functionality in controlling external devices or processes. These relay outputs offer versatile switching capabilities, allowing for precise control and automation of industrial operations. 

Expansion Options: To further extend its relay functions, the TDBS board is designed to accommodate different option cards. These cards provide additional relay channels or specialized functionalities, enhancing the board's adaptability to specific application requirements. 

Flexibility in Configuration: The ability to incorporate option cards empowers users to tailor the board to suit their unique needs. Whether expanding relay capacity or integrating specialized features, this flexibility ensures optimal performance and scalability in diverse industrial settings. Mounting Options It offers versatility in mounting, supporting both DIN-rail and flat mounting configurations. This versatility facilitates seamless integration into various control panels or equipment enclosures, optimizing space utilization and installation efficiency. 

Installation Mounting Options: The board, along with a plastic insulator, can be mounted on a sheet metal carrier, which in turn mounts on a DIN rail. Alternatively, it can be mounted on a sheet metal assembly that bolts directly into a cabinet. These mounting options provide flexibility in installation, catering to different enclosure configurations and space constraints. Terminal Block Connections: Two sets of 48-point terminal blocks, typically utilizing 18 AWG wires, facilitate the connections for relay and contact input circuits. The upper set of terminals, labeled TB1, is dedicated to the relay portion of the board, while the lower set, labeled TB2, is for the contact input circuits. The screw assignments for these terminal blocks mirror those found on the SRLY relay board and the STCI contact input terminal board, ensuring consistency in wiring practices. 

Shield Termination: To maintain proper electromagnetic compatibility (EMC) and prevent interference, shields should be terminated on a separate bracket. This separation helps to minimize signal disturbances and ensures reliable operation and connected devices. Relay Option Board Integration: If additional relay functionality is required, a relay option board can be installed by plugging it onto connectors JW1 and JW2 on the TDBS board. The option board is held securely in place by the force of the connectors. External power, if needed, can be wired to a connector provided on the option board. 

Relay Terminal Functions (TB1): The following table delineates the function of each terminal point on the TB1 set in relation to the presence of an option board: NC (Normally Closed): Represents the normally closed contact of a form C relay. COM (Common): Denotes the common point of a form C relay contact. NO (Normally Open): Indicates the normally open contact of a form C relay. 

SOL (Solenoid Return Circuit): Provides the return circuit path for a solenoid powered by the relay board. VSENSE (Voltage Sense): Serves as the input to a voltage sensor that monitors voltage between VSENSE and COM. RETURN: Establishes the return power path for devices powered by the WROG option, ensuring proper functionality and safety. Configuration TDBS Terminal Board: The terminal board doesn't feature any jumpers or hardware settings. Its configuration relies solely on external connections and the use of option boards. 

WROBH1 Option Board: Option board WROBH1 comes equipped with six jumpers utilized for applying or removing power from a relay. By default, all six jumpers are installed on the board. Removing a jumper from the board indicates the relay is to be used as dry contacts, and power distribution isn't required. 

WROFH1 Option Board: There are no jumpers associated with the WROFH1 option board. 

The inclusion or exclusion of a series fuse for each relay depends on the terminal point used as the relay common. 

The associated WROF fuse for each relay can be removed if direct use of the fuse voltage sensing circuit as a voltage detector is preferred. 

WROGH1 Option Board: Similar to the WROFH1 board, there are no jumpers associated with the WROGH1 option board. For each relay, the corresponding fuse may be removed if the relay is intended for providing dry contacts.T DISCRETE SIMPLEX TEST

IS215VCMIH2BB IS200VCMIH2BCC

IS210MACCH1AGG

SR489-P5-LO-A20-E

MVR1600-4601

D20 EME 2400-21004

IC697MDL350

8101-HI-TX-02

IC698PSA100

IC698RMX016-ED

IC660BBD025

531X303MCPARG1

DS200FSAAG1ABA



  • Tricon 8120E card is in stock.
  • NE870 Network Router ABB 3BSE080239R1
  • ALSTOM V4561484-0100 Amplifier Module Rev 7 Pcb Circuit Board
  • Model 10959-201 and -203 Wall-Mount Audio Messenger Interfaces
  • HIMA X-SB 01985210207 24VDC System bus module
  • HIMA X-FAN 18 03 High-efficiency cooling plate fan
  • HIMatrix F3 AIO8/4 01 HIMA Compact Controller
  • 3BHE039770R0102 PP D539 A102: AC 800PEC Contr. Device
  • ABB CMC 70, Controller, SW-Vers. 1.61/2.11
  • GE SR760-CASE 750/760Feeder Management Relay® Instruction Manual
  • ABB REG670 C30 Version 2.0 General Information
  • REF543KM127BAAA ABB FEEDER TERMINAL
  • Danaher driver SAM-DA-400/480-07N-P4N-F
  • GE FANUC/ALSTOM LC106-1- LE108 LC105 LC106 Spot model
  • ALSTOM AB121丨AY00000000266/B technical parameter
  • GE ALSTOM LE109A-1 control card data
  • GE ALSTOM IR139-1丨063022350 丨80801419 Control card. data
  • Alstom Control Set-UT150-1 Kongjiang-spot
  • ALSTOM AL132丨AL132A Control Card
  • PM1118丨ABB PM118-7BPM1118 MAGNET (NEO) .50LG
  • DEIF DLQ72-PC-PY ROLLS-ROYCE K85240 PITCH INDICATOR 10V
  • Rolls-Royce Marine R10I53S/R10I53S Panel Computer 98H0101A0000I Rev 1.9
  • ROLLS-ROYCE P001240-1 display REV 2
  • ROLLS-ROYCE RRDIO15 I/O ALARM MODULE
  • Rolls-royce UN930 Digital Display Controller 24V
  • ROLLS-ROYCE MARINE LAUER LCA 325.P2 PROFIBUS-DP NET DISPLAY PANEL UN924
  • ROLLS-ROYCE MARINE AS 5880-PC1002 STEERING GEARS-TENFJORD PCB card
  • ROLLS-ROYCE UN31 ECR panel 000127603
  • Rolls-royce ship AS UN991.1 distributing plate
  • ROLLS-ROYCE 5045 K THRUSTER CONTROLLER PANEL
  • Rolls-Royce SLIO 02 Canman controller network
  • Rolls-Royce E-1071 automatically displays 07918 B UN 921 ECR 24VDC
  • ROLLS ROYCE PCC1030C ULSTEIN panel controller card
  • ROLLS-ROYCE KAMEWA PROPELLERS control room panel basic R160637A
  • ROLLS-ROYCE UN925 Panel Controller
  • Rolls-royce Marine AS UN921 OPRETOR panel
  • Rolls-Royce Marine r10I53s/R10I53S Panel Computer 98H0101A0000I
  • ROLLS-ROYCE H1111.0104 ocean controller P/N:75669
  • Rolls-Royce H1111.0203 Marine Controller Version 2.2
  • Rolls-Royce H1111.0102 Marine Controller
  • Rolls-Royce H1127-0101 Marine Controller 00068308H6045/433
  • Rolls-Royce H1111.0103 Marine Controller 75669 Version 2.2
  • EMERSON KJ3221X1-BA2 VE4035S2B1 ATEX Instruction Sheet
  • EMERSON VE4017P0 M-series FOUNDATION™ Fieldbus I/O
  • A6740 16-Channel Output Relay Module for the AMS 6500 Machinery Health Monitor
  • EMERSON A6120 Protection Cards for AMS 6500 Classic Systems
  • A6000 series A6125 electric vibration monitor Emerson
  • EMERSON A6000 series control card A6410
  • EMERSON A6370 Overspeed Protection Monitor
  • ABB 3BHB015651P0001 DKTFM418B Power converter assembly
  • Westingouse Ovation 5X00500G01 Speed detector module
  • Emerson 5X00875G01 Analog input EMOD module
  • UNIOP ETT-VGA-0045 HMI touch unit with colour graphic display and VGA resolution. Available with high-quality TFT
  • General Electric Mark VI series IS200JPDBG1A IS200JPDBG1ABB printed circuit
  • General electric IS200EDISG1A distribution board
  • IS400TDBTH6A Mark* VIe control system Extended product life cycle description
  • DS200DCFBG1BLC General Electric Power Supply Board
  • 5485C Velocity Sensor Metrix
  • ABB 3BSE031155R1 BC810K02 CEX-bus Interconnection Unit
  • DCS602-0250-51-15 ABB DCS 600 Overload Capability
  • DCS602-0520-51/15 ABB Permanent drive
  • 853-032776-001 Lam Research Paddle Lifter
  • Modbus Plus Communication Module MVI56-MBP
  • PLC board (head) module KEBA CPU IP70
  • DS200DSFBG1A Driver/Shunt Feedback Board technical specifications
  • DS200DPCAG1ADB IOS + Power Connect Board Technical Specifications
  • DS200DPCAG1A IOS & Power Connect Card Assembly
  • Hirschmann MM20-P9P9T1T1SAHH Media Converters
  • Hirschmann MM20-P9P9P9P9SAHH In installation instructions
  • Hirschmann MM4-2TX/SFP Media Converters
  • Hirschmann MM4-4TXSFP-datasheet
  • Hirschmann MM3-1FXL23TX1_techdata MM3-1FXL2/3TX1
  • Hirschmann MM3-4FXS2 PowerMICE series industrial switch products
  • Hirschmann MM3-2FXS2/2TX1 Media Converters
  • MM3-1FXM2/3TX1 Hirschmann Ethernet & Communication Modules
  • Hirschmann MM3-4TX5 Media module
  • Hirschman MM2-2FXM3/2TX1 Media Module article will analyze the technical features of this product in detail
  • Hirschmann MM2-4TX1 Performance parameters of compact and modular managed Ethernet switch
  • MS4128-L3E ATEX Power mouse, modular, managed industrial Ethernet switch
  • Hirschmann MS4128-L2P ATEX 943009101, Power MICE, modular, managed Industrial
  • Hirschmann Managed Ethernet Switch MM20-M2M2T1T1SAHH
  • Hirschmann MM20-T1T1T1T1SZHH Managed Ethernet switch
  • Hirschmann MM20-M4T1T1T1SAHH Media converter
  • Detailed explanation of Hirschmann GMM20-mmmmmev9HHS9 xx.x.xxx Ethernet module
  • Hirschmann MM20-M2M2M2T1SAHH Management Ethernet Switch Function and Configuration Guide
  • Product introduction and technical specifications of Hirschmann MM20-M2M2M2M2EAHH media converter
  • Hirschmann MM20-M4M49999TAHH Media converter
  • Hirschmann MM20-Z6Z6Z6Z6TAHH Media converter
  • Media converter MM20-M2M29999EAHH Data
  • Media converter MM20-G2T1T1T1SAHH Hirschmann
  • Hirschmann Media converter MM20-M2T1T1T1TAHH
  • Hirschmann Ethernet module GMM GMM20-VVVVVVVVSY9HHS999.9.XX
  • Managed Ethernet Switch MM20-M4M4M4M4TAHH
  • Hirschmann Managed Ethernet Switch MM20-M2M2T1T1SSHH
  • Hirschmann Managed Ethernet Switch MM20-Z6Z6Z6Z6SSHH
  • Media converter MM20-T1T1T1T1TAHH Hirschmann
  • Hirschmann Media converter MM20-M4M4T1T1EAHH
  • MM20-M4M4M4M4EAHH Hirschmann Media converter
  • Hirschmann Media converter MM20-M2M2M2M2SAHH
  • Hirschmann Managed Ethernet Switch MM20-S2S2T1T1SYHH
  • ABB SDCS-POW-4 POWER SUPPLY
  • AMAT 0090-35032 ARSINE DETECTOR 0-1000PPB
  • SMC XLFD-100D-X1236 high vacuum valve 0.4 ~ 0.7MPa 5 ~ 60°C
  • 50DW412745 Control Module United Technologies Carrier
  • Carrier 50DW404638 Control module CEAS430189-02
  • TRICONEX 2481 I/O Module
  • WARNER ELECTRIC HMCS2000-PRG Programmer
  • WARNERELECTRIC MCS2000-ECA Digital control
  • Related Manuals for WAGO WAGO-I/O-IPC 758-870 and 58-873Series
  • IOC4T-RLC16 Vibro-Meter company VM600 system and sensor technical data
  • MEGGITT VIBRO-METER 200-510-076-114 VM600 MPC4 Descriptive data
  • IPC704 Signal conditioner MEGGITT VIBRO-METER IPC704 244-704-000-032 AMP
  • GSI127 galvanic separation unit MEGGITT VIBRO-METER GSI 127 244-127-000-017 A1-B02 MODULE
  • ABB Relion® 650series REC650/REL650/RET650/REB 650/REQ 650
  • Rexroth Sercos III analog, axis module R-ILB S3 AI12 AO4 SSI-IN4
  • DS200DMCBG1ABB DOS DUP Processor Board
  • DS200DMCAG1AAA Gen/Log/Key Interface Board
  • DS200DKLBG1ABB Power Connect Board
  • General Electric DS200DENCF1BDE01 EEPROM with Firmware
  • DS200DDTBG2ABB LCI Auxiliary I/O Terminal Board
  • DS200DCVAG1A DC Power and Instrumentation Board
  • DS200DCPAG1 DC Power Board GE General Electric
  • DS200DCFBG1B DC Feedback Power Supply Board
  • DS200DCFBG1AAA DC Power Feedback Board
  • DS200DACAG1 TC/DC AC/DC Convertor Board
  • DS200CVMAG3AEB Cap/Fuse Voltage Monitor Board
  • DS200CVMAG1AEB Capacitor Voltage Monitor Assembly
  • DS200CTBAG1A Analog Termination Module