KONG -Y
NameDescriptionContent
Location:
product
IS200TREGH1A Turbine emergency trip terminal board
❤ Add to collection

IS200TREGH1A Turbine emergency trip terminal board

IS200TREGH1A
U.S.$23380.00
U.S.$9085.00
U.S.$8630.75
U.S.$8449.05
Weight:0.000KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
IS200TREGH1A

Part Number IS200TREGH1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VIe Function Module Availability In StockIS200TREGH1A is a Turbine Emergency Trip Terminal Board manufactured and designed by General Electric as part of the Mark VI Series used in Speedtronic Control Systems. 

The I/O controller manages TREG, which powers three emergency trip solenoids. The TREG and TRPG terminal boards can connect up to three trip solenoids. TREG supplies the solenoids with the positive side of the dc power, while TRPG supplies the negative side. The I/O controller controls the 12 relays on TREG, nine of which form three groups of three to vote inputs controlling the three trip solenoids, as well as emergency Overspeed protection and emergency stop operations. There are a number of board types as follows: The H1B version is utilized in place of the H1A version for new production. The main version for 125 V dc applications is H1B. On the board, redundant power is created by bimodally combining control power from the JX1, JY1, and JZ1 connectors to power the economizing relays and status feedback circuits. 

The trip relay circuits ensure power isolation. Applications requiring 24 V dc use H2B. Other traits are identical to those of H1B. A modified form of H1B called H3B is used in systems with redundant TREG boards. The JX1 connector is the only source of power for the feedback circuit and the cost-saving relay. H4B is a modified form of H1B that is used in TREG board redundancy systems. The JY1 connector is the only source of power for the feedback circuit and the cost-saving relay. A modified variant of H1B called H5B is used in systems with redundant TREG boards. The JZ1 connector is the only source of power for the feedback circuit and the cost-saving relay. Typically, one H3B and one H4B board are used in tandem in redundant TREG applications. To preserve the control power separation built into these systems, system repairs must be carried out using the appropriate type of board. MARK VI SYSTEMS: The TPRO interfaces with the TREG terminal board in Mark VI systems. TREG and the TPRO module are connected by cables with molded plugs. MARK VIe SYSTEMS: TREG is managed by the PPRO pack on SPRO on Mark VIe systems. The D-type connectors on SPRO accept the PPRO I/O packs for insertion. TREG and the SPRO board are connected by cables with molded plugs. INSTALLATION: The first I/O terminal block is directly wired to the three trip solenoids, the economizing resistors, and the emergency stop. 

The second terminal block can accept wiring for up to seven trip interlocks. OPERATION: The J2 power cable and the trip solenoids are the only connections to the control modules since the I/O controller controls all aspects of TREG. When a turbine trips in simplex systems, a third cable transmits a trip signal from J1 to the TSVO terminal board, which operates a servo valve clamp. SOLENOID TRIP SETS: The controller's application software is used to launch tests of the trip solenoids. Through the PTR relays from the controller or the ETR relays from the protection module, each trip solenoid can be manually tripped one at a time during online tests. In order to provide a reliable indication that the solenoid has tripped, a contact from each solenoid circuit is linked back as a contact input. Additionally, primary and emergency offline Overspeed tests are offered for the purpose of verifying actual trips that have been affected by software-simulated Overspeed conditions. DIAGNOSTICS: The TREG board and linked devices are subjected to diagnostic tests by the I/O controller. The diagnostics cover the solenoid voltage source, the trip relay driver and contact feedbacks, the economizer relay driver and contact feedbacks, the K25A relay driver and coil, the servo clamp relay driver and contact feedback, and the economizer relay driver and contact feedbacks. A fault is produced if even one of these deviates from the desired value. The I/O controller queries the ID devices on the TREG connections JX1, JY1, and JZ1. The terminal board serial number, board type, revision number, and plug location are all encoded on the read-only ID device chip. A hardware incompatibility fault is produced when a mismatch is found while reading the chip by the I/O board.TERM. BD., TRIP EMER

Related models

DS200SHVMG1AFE

IC660ELB912

IS230TVBAH2A

IS215VCMIH2BB IS200VCMIH2BCC

IS210MACCH1AGG

SR489-P5-LO-A20-E

MVR1600-4601

D20 EME 2400-21004

IC697MDL350

8101-HI-TX-02

IC698PSA100

IC698RMX016-ED

IC660BBD025

531X303MCPARG1

DS200FSAAG1ABA

  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930 presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • Configuration for AMS 6500 Protection Monitors
  • EMERSON DeltaV™ M-series Traditional I/O
  • EMERSON DeltaV™ SQ Controller
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • ABB Ethernet Modules EI 802F
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • Control product - Soft starter PST/PSTB (Intelligent Type) ABB
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives