KONG -Y
NameDescriptionContent
Location:
product
IS200TRLYH1B Mark VIe series relay output terminal board
❤ Add to collection

IS200TRLYH1B Mark VIe series relay output terminal board

IS200TRLYH1B
U.S.$10359.00
U.S.$6881.00
U.S.$6536.95
U.S.$6399.33
Weight:0.000KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
IS200TRLYH1B

IS200TRLYH1B Mark VIe series relay output terminal board

Part Number IS200TRLYH1B Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI Function Module Availability In StockThe IS200TRLYH1B is a Relay Output Terminal Board developed by GE under the Mark VIe series. There are 12 plug-in magnetic relays on the Relay Output with Coil Sensing (TRLY1B) terminal board. The first six relay circuits can be set up with jumpers to drive external solenoids or dry, Form-C contact outputs. For field solenoid power, a basic 125 V dc or 115/230 V ac source or an optional 24 V dc source with personal jumper-selectable fuses and onboard suppression can be offered. 

The next five relays  are isolated Form-C contacts that are not powered. An isolated Form-C contact is used on output 12 for specialized uses like ignition transformers. IS200TRLYH1B Compatibility Simplex and TMR applications are supported by the PDOA/YDOA I/O pack when using the TRLY 1B. The terminal board's DC-37 pin connections accept the I/O pack as a plug-in. For simplex systems, connector JA1 is used, while for TMR systems, connectors JR1, JS1, and JT1 are used. IS200TRLYH1B Installation Wire the two I/O terminal blocks on the terminal board, TRLY1B Terminal Board Wiring, directly with the wires for the 12 relay outputs. Each block has 24 terminals that may accommodate wires up to 12 AWG and is secured with two screws. Each terminal block has a shield terminal strip on the left side that is connected to chassis ground. The solenoid power for outputs 1-6 should be connected to JF1. Power can be daisy-chained to additional TRLYs using JF2. Alternatively, when JF1/JF2 are not in use, power can be connected directly to TB3. Connect output 12 of the special solenoid to connector JG1 to provide electricity. The factory removes jumpers JP1-JP6 and ships them in a plastic bag. If a field solenoid needs electricity, reinstall the proper jumper. Check each loop's energization individually in accordance with best practices, and install the jumpers as necessary. Remove the fuses from isolated contact applications to make sure that the power bus is free of suppression leakage. IS200TRLYH1B Operation Dry Contacts If these terminal boards are utilized as dry contacts to switch ac voltage utilizing circuits 01 through 06 while also receiving 125 V dc power through JF1, JF2, or TB3, ac power will be present on the "NO" relay terminal until all fuses and jumpers for a circuit are removed. Additionally, the contact will bind the ac voltage to N 125 V dc when it shuts. Similar circumstances apply to the P-125. 

The sum of the ac peak voltage and the 125 V dc is applied to MOVs linked between the dc and ground because the neutral of the majority of ac supply is grounded. The MOV rating is adequate to tolerate 120 V ac in those situations. The peak voltage will, however, exceed the MOV rating in 240 V ac applications, leading to failure. It is best to avoid using these circuits for ac switching because of this. Simplex On the TRLY 1B are mounted jumpers, fuses, and relay drivers. D-type connectors monitor feedback voltages and transmit control signals between the I/O processors and TRLY1B through JA1 for simplex operation. Relays have a 3.0 A rating and are driven at the frame rate. 500 V ac is the maximum allowable contact-to-contact voltage for one minute. For one minute, the coil to contact voltage is rated at 1,500 V ac. 10 ms is the normal operating time. 

 TMR Relay control signals are fanned into TRLY1B for TMR applications from the three I/O processors R, S, and T through connectors JR1, JS1, and JT1. These signals are put to a vote, and the outcome determines which relay driver gets the signal. All three I/O processors provide shared diode power to the relay coils. Diagnostics The following diagnostic procedures are performed on the terminal boards' components: At the frame rate, each relay's output (coil current) is monitored and compared to the command. An alarm is latched if there is no agreement after two inspections in a row. An alarm is latched if the solenoid excitation voltage drops below 12 V dc, which is monitored downstream of the fuses. A composite diagnostics alert, L3DIAG xxxx, is triggered if any one of the outputs becomes unhealthy. A hardware incompatibility fault is produced when an ID chip is read by the I/O processor and a mismatch is discovered. Monitoring of relay contact voltage. 

The configuration application has information about each diagnostic's specifics. The diagnostic signals can be individually latched and, if they become healthy, reset with the RESET DIA signal. Configuration Adjustments to the board are made as follows: JP1JP12 jumpers Insert jumpers for the chosen relays if contact voltage sensing is necessary. FU1FU12 fuses Two fuses should be added to each power circuit supplying relays 1-6 if electricity is required for them. For instance, FU1 and FU7 provide power to relay output 1. IS200TRLYH1B Features On the left edge of the board are huge black terminal blocks. Each terminal block contains twenty-four silver metal terminals. There are a total of 48 terminals in all. On the terminal blocks, each terminal has been designated in white type. On the right side of the board, there are four connector ports. Three connector ports are vertically aligned on the edge, while the fourth sits parallel to the connector port at the bottom. A transistor is located on both sides of each relay. A circular red MOV, or metal oxide varistor, is paired with each transistor. On the upper part of the board, five of these relays are vertically aligned. On the lower portion of the PCB, five more relays have been aligned.TERM BOARD

  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930 presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • Configuration for AMS 6500 Protection Monitors
  • EMERSON DeltaV™ M-series Traditional I/O
  • EMERSON DeltaV™ SQ Controller
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • ABB Ethernet Modules EI 802F
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • Control product - Soft starter PST/PSTB (Intelligent Type) ABB
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives