KONG -Y
NameDescriptionContent
Location:
product
IS200TRLYS1D GE Manufacturing Policy Series Mark VI/VIe Function Module
❤ Add to collection

IS200TRLYS1D GE Manufacturing Policy Series Mark VI/VIe Function Module

IS200TRLYS1D
U.S.$5497.00
U.S.$7880.00
U.S.$7486.00
U.S.$7328.40
Weight:0.265KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
IS200TRLYS1D

Part Number IS200TRLYS1D Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS200TRLYS1D is a Relay Output Board developed by GE. It is a part of Mark VIeS control system. 

The terminal board is engineered with specific features to accommodate the needs of industrial applications requiring solenoid control and integrity sensing. 

The board is equipped with six plug-in magnetic relays, each featuring Form-C contact outputs. 

These relays are fused and powered to efficiently drive external solenoids, ensuring reliable operation in various industrial settings. Supported power sources include standard 24 V DC or 125 V DC, providing flexibility in power supply options to suit specific application requirements.FEATURES Solenoid Integrity Sensing: Special feedback mechanisms are integrated into each relay circuit to detect potential issues with external solenoids. This sensing capability, performed between the normally open (NO) output terminal and the solenoid (SOL) output terminal, allows for proactive maintenance and troubleshooting by identifying faulty solenoids. 

Six-Relay Configuration: The board features six relays, providing expanded relay capacity beyond the standard configuration. 

This increased relay count offers greater flexibility and versatility in system design and operation. 

Compatibility with 24/125 V DC Applications: Designed specifically for 24/125 V DC applications, the board ensures compatibility with specific voltage requirements, ensuring optimal performance and reliability in targeted applications. Dual Normally Open (NO) Contacts: Relay circuits include a normally open (NO) contact on both the source side and the return side. This configuration enhances flexibility and functionality in controlling external devices and circuits. 

Non-Configurable for Dry Contact Use: The relays are not configurable for dry contact use, ensuring compatibility with the intended application. This design choice streamlines installation and eliminates potential compatibility issues. emoval of Input Relay Coil Monitoring: Input relay coil monitoring is removed from the board, streamlining its functionality for solenoid control and integrity sensing. This optimization enhances operational efficiency and simplifies maintenance procedures. 

Field Solenoid Integrity Monitoring: The terminal board provides monitoring of field solenoid integrity, enhancing system reliability and safety. 

This feature ensures that solenoids are functioning correctly, reducing the risk of malfunctions and downtime. 

Exclusion of Special-Use Relay for Ignition Transformer: The board does not include a special-use relay for driving an ignition transformer. Instead, it focuses on solenoid control and integrity monitoring, ensuring optimized performance for its intended application. INSTALLATION Relay Output Connection Connect the wires for the six relay outputs directly to the TB1 terminal block on the terminal board. The TB1 block is securely held down with two screws and features 24 terminals designed to accept wires up to 12 AWG, providing ample space for wiring connections. Ensure proper alignment and secure attachment of the wires to the terminal block to prevent loose connections or electrical hazards. Grounding Adjacent to the TB1 terminal block, locate the shield terminal strip attached to chassis ground. Properly ground the terminal board by connecting it to the shield terminal strip, enhancing safety and minimizing the risk of electrical interference. Solenoid Power Connection Connect the solenoid power for outputs 1-6 to JF1, ensuring proper polarity and secure connections. JF2 can be utilized to daisy-chain power to other TRLYS1D boards, providing a convenient and streamlined power distribution solution. Avoid using TB3 for solenoid power connection to prevent potential issues or conflicts. Final Checks Double-check all connections to ensure they are secure and properly aligned. Verify that the wiring configuration complies with the specifications and requirements of the application. Perform thorough testing to confirm proper functionality of the relay outputs and solenoid power supply.TERMINATION BD., RELAY

  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930 presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • Configuration for AMS 6500 Protection Monitors
  • EMERSON DeltaV™ M-series Traditional I/O
  • EMERSON DeltaV™ SQ Controller
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • ABB Ethernet Modules EI 802F
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • Control product - Soft starter PST/PSTB (Intelligent Type) ABB
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives