KONG -Y
NameDescriptionContent
Location:
product
IS220PPRAS1A GE Manufacturing Policy Series Mark VI/VIe Function Module
❤ Add to collection

IS220PPRAS1A GE Manufacturing Policy Series Mark VI/VIe Function Module

IS220PPRAS1A
U.S.$23380.00
U.S.$4085.00
U.S.$3880.75
U.S.$3799.05
Weight:3.550KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
IS220PPRAS1A

Part Number IS220PPRAS1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS220PPRAS1A is an Emergency Turbine Protection Terminal Board manufactured and designed by General Electric as part of the Mark VIe Series used in distributed control systems. A backup Overspeed protection system that is independent is offered by the Emergency Turbine Protection (PPRA) I/O packs and related TREA terminal board. Inputs for the main control and isolated trip contacts are also given a separate watchdog role by them. A protection system is made up of three triple modular redundant (TMR) PPRA I/O packs that are mounted to a TREA terminal board and have a WREA option board attached. The standard Mark VIe PPRO Emergency Turbine Protection I/O pack is the ancestor of PPRA. 

In applications where dual-speed sensors per shaft are fanned to three protective I/O packs, it needs new hardware and modified code to provide six-speed inputs. The majority of the PPRA's settings, parameters, and behavior are the same as those in the PPRO. The TREA terminal board with the WREA option board is the only one that supports PPRA. Other settings that PPRO supports cannot be used with PPRA. In order to communicate with the control modules through IONet, PPRA additionally has an Ethernet connection. The primary and backup trip prevention systems for the Mark VIe control are built to work together at the trip terminal board level. The Turbine Primary I/O pack (PTUR), when connected with PPRA/TREA, operates a primary trip board (usually TRPA), providing primary protection. 

A TREA terminal board installed with PPRA offers backup protection. PPRA supports six-speed signals (specified as three sets of speed pairs) for hardware-implemented Overspeed protection, acceleration, and deceleration. It keeps an eye on the primary control's performance. Through a thorough set of feedback signals, PPRA keeps track of the status and functionality of the TREA trip board. The backup trip relays on the TREA board will trip in the event of a failure, and the primary control will also trip. The primary control operation has no impact on PPRA and is completely independent of it. COMPATIBILITY: For usage in IEC 61511-approved safety loops, PPRA is offered in a version that is IEC 61508 certified. 

The certified versions of the PPRA module are PPRAS1A with TREAS1A and WREAS1A. When using TREA, which PPRA mounts on directly, the WREA option board must be installed on the PPRA application-specific circuit board Option Header connector. Only three PPRA I/O packets will work properly with a PPRA installed on a TREA with WREA. It is not possible to operate a single or twin pack. In systems with a single controller, the R network of the controller, the S network of the controller, the JY1 connector of the controller, and the JZ1 connector of the controller should all be linked to the PPRA. The same controller powers all three networks. INSTALLATION: Mount the TREA terminal board firmly. Immediately connect the TREA with three PPRA I/O packets. Using the holes on the terminal board mounting bracket, insert the threaded posts on PPRA that are situated on either side of the Ethernet ports. To ensure a tight fit between the DC-62 pin connector on the PPRA and the terminal board, adjust the bracket's position. Secure the mounting bracket firmly. Only one adjustment should be necessary during the lifespan of the product. Lock PPRA in place by firmly tightening the nuts on the threaded posts. 

Depending on the setup of the machine, connect either one or two Ethernet wires. Ethernet connections are not sensitive to PPRA, which chooses the appropriate operation over either port. Connect the module's power connector to an electrical source to supply power. The I/O module has a built-in soft-start feature that regulates current levels when used. Configure the module using the ToolboxSTprogram as appropriate. OPERATION: A processing board is shared by each Mark VIe Ethernet I/O pack or module. It contains the following: A quick processor with RAM and flash memory is number one. Two plugs for entirely independent 10/100 Ethernet ports Hardware reset and watchdog timer circuit A sensor for internal temperature LEDs that indicate the status The capacity to read IDs on other boards and electronic identification An input power connector with a current limiter and a soft start Local power supplies, which also include monitoring and sequencingIO PACK, SPEED IN PROTECTION



  • نظام التحكم الرقمي في التحفيز الكهربائي BASLER DECS-200
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DIGITAL EXCITATION CONTROL SYSTEM DECS-300
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • ABB Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA PC connection for high-precision data acquisition with ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930 presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System