WATLOW MLS300-PM Processor Module (Central CPU),Discontinued
Watlow Anafaze MLS300-PM is the core Processor Module (PM) and central "brain" of the MLS300 modular multi-loop control system.
As a central CPU, it handles the logic, PID calculations, and system coordination for high-density thermal processes.
1. Introduction
The MLS300-PM Processor Module is the executive unit of the MLS300 system.
It is designed to work in a "stack" with expansion modules, primarily the AIM (Analog Input Module) and CIM (Control Interface Module).
While it does not directly house the sensor inputs (which reside in the AIM), the PM processes all incoming data and executes complex control strategies for up to 16 or 32 loops.
Though currently discontinued, it remains a vital component in legacy industrial automation and semiconductor manufacturing tools.
2. Technical Parameter Table
| Feature | Specification |
| Module Function | Central Processor Unit (CPU) |
| Loop Capacity | Supports up to 16 or 32 loops (based on firmware) |
| Power Input | 12 to 24 VDC |
| Display | 2-Line, 16-Character Vacuum Fluorescent (VFD) |
| User Interface | Tactile Keypad (on-face configuration) |
| I/O Capacity | Supports 36 Digital I/O channels (via backplane/boards) |
| Control Algorithms | PID, Cascade, Ratio, and Differential Control |
| Mounting | 1/8 DIN Panel Mount or Surface Mount |
| Weight | Approximately 1.65 lbs (0.75 kg) |
3. Product Advantages and Features
High-Density Logic: Consolidates the processing power of dozens of individual controllers into a single module, reducing cabinet complexity.
Versatile Control Modes: Supports advanced process features like Ramp/Soak, Cascade control, and Ratio control, which are often required in chemical or semiconductor processing.
On-Board Diagnostics: Provides real-time feedback on system health, including "System Safe" relays and CPU watchdog timers to prevent process runaway.
Job/Recipe Storage: Allows for multiple process configurations (Jobs) to be stored in non-volatile memory and recalled instantly.
4. Application Cases
Semiconductor Fabrication: Controlling complex multi-zone bake stations and CVD (Chemical Vapor Deposition) processes.
Multi-Zone Extrusion: Coordinating the thermal profile of long-barrel plastic extruders to ensure material consistency.
Environmental Stress Chambers: Managing the synchronization of temperature, humidity, and airflow loops.
Industrial Kilns/Ovens: Precise ramp-to-setpoint control for ceramic firing or composite curing.
5. Other Models in the Same Series
Since the MLS300 is a modular system, the PM is typically paired with:
MLS300-AIM: Analog Input Module (the physical interface for thermocouples/RTDs).
MLS300-CIM: Communication Interface Module (enables Modbus RTU/Serial comms).
MLS300-OIT: Remote Operator Interface Terminal (for external monitoring).
TB50 / TB18: Terminal Boards for physical wiring of high-density I/O.
6. Installation and Maintenance
Installation
Mounting: Ensure the unit is installed in a clean, ventilated 1/8 DIN cutout. If stacking modules, ensure ribbon cables are seated firmly.
Power: Use a regulated DC power supply. Since the PM controls the system timing, power fluctuations can cause "Watchdog" resets.
Grounding: Connect the chassis ground to a dedicated low-impedance industrial earth to prevent VFD display noise.
Maintenance
Memory Battery: The internal lithium battery retains the "Job" configurations. If the "Low Battery" alarm appears on the display, replace it immediately to avoid losing logic settings.
EPROM Updates: Ensure the EPROM chip version is consistent across all modules in the stack to prevent communication "Time-Out" errors.
Display Care: The VFD can dim over decades of use; use the "Screen Saver" or "Dim" settings in the setup menu to extend its lifespan.
7. Unique Product Description
"The Watlow MLS300-PM is the master architect of high-density thermal control.
By serving as the central intelligence for up to 32 loops, it transforms massive amounts of raw sensor data into surgical PID precision.
It is the definitive legacy CPU for systems where downtime is not an option and thermal uniformity is the only metric that matters."
| ABB | LDSTA-01 |
| ABB | SDCS-AMC-CLAS2 |
| ABB | TVOC-2-240 1SFA664001R1001 |
| ABB | CS31 |
| ABB | RFO810 |
| ABB | RMU811 |
| ABB | 5SHY6545L0001 AC10272001R0101 5SXE10-0181 |
| ABB | 5SHY4045L0001 3BHB018162R0001 |
| ABB | SCYC51040 58052680E |
| ABB | CB801 3BSE042245R1 |
| ABB | SCYC51010 58052515G |
| ABB | SCYC51090 58053899E |
| ABB | SCYC51020 58052582H |
| ABB | PP865A 3BSE042236R2 |
| ABB | TP857 3BSE030192R1 |
| ABB | OCAHG 492838402 |
| ABB | OCAH 940181103 |
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|
Add: High-tech Software Park, Xiamen City, Fujian Province
Mobile: +86-17750019513(WhatsApp)
Email: yy4291644@gmail.com
Website: https://www.abb-sis.com