KONG -Y
NameDescriptionContent
Location:
product
HIRSCHMANN MM20-P9P9M2T1SAHH Fast Ethernet media module
❤ Add to collection

HIRSCHMANN MM20-P9P9M2T1SAHH Fast Ethernet media module

HIRSCHMANN MM20-P9P9M2T1SAHH Fast Ethernet media module

U.S.$10450.00
U.S.$9145.00
U.S.$8687.75
U.S.$8504.85
Weight:1.290KG
Quantity:
(Inventory: 2)
Buy now
Add to cart
Description

HIRSCHMANN MM20-P9P9M2T1SAHH Fast Ethernet media module


The HIRSCHMANN MM20-P9P9M2T1SAHH is a hot-swappable, 4-port hybrid Fast Ethernet media module designed for Hirschmann’s modular MICE (Modular Industrial Communication Equipment) switch family, including the MS20 and MS30 basic switch chassis.

What makes the P9P9M2T1 configuration unique is its multi-tier media aggregation layout on a single module backplane slot:

2 × Single-Mode SC Fiber Ports (P9. P9): $100text{Base-FX}$ duplex SC optical interfaces ($1300text{ nm}$) capable of long-haul fiber uplinks up to $30text{ km}$.

1 × Multi-Mode SC Fiber Port (M2): $100text{Base-FX}$ duplex SC optical interface ($1300text{ nm}$) for short-to-medium range fiber links up to $5text{ km}$.

1 × Shielded RJ45 Copper Port (T1): $10/100text{Base-TX}$ copper port with Auto-Negotiation and Auto-MDI/MDI-X support for direct local device connectivity.

By housing three distinct media types—long-range single-mode optical, short-range multi-mode optical, and copper—in one module, it eliminates the need for external media converters or multi-slot expansions.

2. Product Advantages and Features

3-in-1 Media Flexibility: Bridges long-distance backbone rings, local building/plant multi-mode fibers, and legacy copper field drop connections simultaneously.

Hot-Swappable Backplane Architecture: Plugs directly into the MS20/MS30 backplane under full power without interrupting active network traffic on adjacent slots.

Industrial Hardening & EMI Immunity: Built to withstand severe electromagnetic interference (EMI), high mechanical shock, and continuous vibration in substation and factory automation environments.

Low Power Consumption: Draws power directly from the main switch unit ($approx 5text{ W} - 7text{ W}$), reducing heat dissipation in control cabinets.

Integrated LED Diagnostics: Per-port diagnostic LEDs provide real-time status visibility for power, link state, traffic activity, and transmission speed.

3. Application Cases

A. Substation & Power Grid Automation

Connects remote substations over dual long-haul single-mode lines ($30text{ km}$ via P9 ports), links local sub-station IEDs (Intelligent Electronic Devices) over multi-mode optical lines (M2 port) for noise isolation, and services an HMI or maintenance PC locally (T1 port).

B. Railway Tracksides & Highway Infrastructure

Used in daisy-chain or redundant ring topologies along transport corridors. The dual P9 ports maintain long-distance ring redundancy between trackside cabinets, while the M2 port links to nearby multi-mode tunnel control units and the T1 port connects directly to IP cameras or sensors.

C. Large Manufacturing Plants

Acts as a media converter hub inside factory floor control panels, aggregating long-run plant backbone cables with legacy multi-mode fiber drops in adjacent workshop bays.

4. Other Models in the Same Series

Model Part NumberFiber / Copper ConfigurationTarget Transmission Reach
MM20-P9P9M2T1SAHH2 × SM SC + 1 × MM SC + 1 × RJ45Long-range + Short-range + Local Copper
MM20-P9P9T1T1SAHH2 × Single-mode SC + 2 × RJ45Dual long-haul optical uplink ($30text{ km}$) + Dual Copper
MM20-M2M2T1T1SAHH2 × Multi-mode SC + 2 × RJ45Short-range fiber ($5text{ km}$) + Dual Copper
MM20-T1T1T1T1SAHH4 × RJ45 Copper (10/100Base-TX)High-density local copper drop expansion
MM20-Z6Z6SAHH4 × Fast Ethernet SFP SlotsCustom SFP transceiver deployment
MM20-P9P9M2T1EBH2 × SM SC + 1 × MM SC + 1 × RJ45Extended Temp ($-40^circtext{C}$ to $+70^circtext{C}$) + Conformal Coating

5. Installation and Maintenance

Installation Steps

ESD Safety: Wear an anti-static wrist strap attached to cabinet ground prior to unpacking or inserting the module.

Backplane Insertion: Align the module with the internal guide rails of an unpopulated slot on the host MS20 or MS30 chassis. Push until the backplane connector locks into place.

Mechanical Fastening: Hand-tighten top and bottom captive thumbscrews on the module faceplate to secure the module and establish ground continuity.

Cabling:

Insert $9/125,mutext{m}$ single-mode fiber jumpers into Ports 1 and 2 (P9. P9).

Insert $50/125,mutext{m}$ or $62.5/125,mutext{m}$ multi-mode fiber jumpers into Port 3 (M2).

Insert Cat5e/Cat6 STP cable into Port 4 (T1).

Maintenance Guidelines

Optical Dust Caps: Keep rubber protective caps inside unpopulated SC receptacles to protect sensitive internal laser optics from airborne dust and oil.

Live Maintenance: The module can be safely extracted or replaced without shutting down power to the host switch frame.

Cleaning: Clean optical fiber connector end-faces with alcohol-free optical lint-free wipes or optical cleaning pens if optical loss increases.


  • CTI 2500 Series® Slice Ethernet Remote I/O System
  • CTI 500 Series® Compact Programmable Automation Control System
  • CTI 2500 Series® Classic Programmable Automation Control System
  • CTI 2500 Series® Bases
  • SHINKAWA VM-25 Condition Monitoring System UPDATED
  • SHINKAWA VM-5 SERIES OPTIONS
  • ABB SACO 64D4 Annunciator unit
  • ABB SPAU 140 C Synchro-check relay
  • HONEYWELL TDC 3000X Advanced Process Manager
  • HONEYWELL ENHANCED MICRO TDC 3000
  • VIBRO-METER VM600Mk2/ VM600 XMx16 + XIO16T extended condition monitoring modules
  • VIBRO-METER VM600Mk2/ VM600 RPS6U rack power supplies
  • VIBRO-METER VM600Mk2/ VM600 ABE056 slimline rack
  • VIBRO-METER VM600Mk2 RLC16Mk2 relay modules
  • VIBRO-METER VM600Mk2 MPC4Mk2 + IOC4Mk2 machinery protection and condition monitoring modules
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • ADLINK cPCI-8168 Advanced 6U CompactPCI 8-axis Motion Controller with One HSL Network
  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK Centralized Motion Controllers PCI-8254/8258
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3o
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • نظام التحكم الرقمي في التحفيز الكهربائي BASLER DECS-200
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DIGITAL EXCITATION CONTROL SYSTEM DECS-300
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • ABB Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA PC connection for high-precision data acquisition with ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET