KONG -Y
NameDescriptionContent
Location:
product
HIRSCHMANN MM20-P9T1T1T1SAHH  hot-swappable hybrid media module
❤ Add to collection

HIRSCHMANN MM20-P9T1T1T1SAHH hot-swappable hybrid media module

HIRSCHMANN MM20-P9T1T1T1SAHH  hot-swappable hybrid media module

U.S.$11560.00
U.S.$10450.00
U.S.$9927.50
U.S.$9718.50
Weight:1.290KG
Quantity:
(Inventory: 2)
Buy now
Add to cart
Description

HIRSCHMANN MM20-P9T1T1T1SAHH  hot-swappable hybrid media module


Product Overview

The HIRSCHMANN MM20-P9T1T1T1SAHH is a hot-swappable hybrid media module engineered for Hirschmann's MICE switch series (MS20 and MS30 basic switches).

Equipped with 1 × Single-Mode SC Fiber Port ($1300text{ nm}$, up to $30text{ km}$ distance) and 3 × RJ45 Copper Ports (10/100Base-TX), this module enables long-haul optical uplink transmission back to central control networks while serving local equipment via high-density copper drops.

2. Technical Parameter Table

ParameterSpecification
ManufacturerHirschmann (Belden)
Product SeriesMICE (Modular Industrial Communication Equipment)
Full Part NumberMM20-P9T1T1T1SAHH
Total Port Count4 Ports
Port 1 Interface1 × Single-Mode 100Base-FX (Duplex SC Connector, $1300text{ nm}$)
Ports 2, 3, 4 Interfaces3 × Shielded RJ45 (10/100Base-TX, Auto-MDI/MDI-X, Auto-Negotiation)
Fiber Transmission ReachUp to $30text{ km}$ over $9/125,mutext{m}$ single-mode optical fiber
Copper ReachUp to $100text{ m}$ over Cat5e/Cat6 STP cable
Backplane Power Draw$approx 4text{ W} - 6text{ W}$ directly via host MS20/30 switch frame
Protection RatingIP20 (Industrial Enclosure)
Hot-SwappableYes (Live insertion/removal supported)

3. Environmental Tolerance Conditions

Operating Temperature: $0^circtext{C}$ to $+60^circtext{C}$ (Standard industrial rating)

Operating Humidity: 10% to 95% (Non-condensing)

Vibration Resistance: Compliant with IEC 60068-2-6 ($1text{g}$, $10text{ Hz} - 150text{ Hz}$)

Shock Immunity: Compliant with IEC 60068-2-27 ($15text{g}$ shock, $11text{ ms}$ duration)

EMC / Interference: Heavy industrial EN 61000-6-2 and EN 61000-4 series (ESD, Burst, Surge)

4. Operating Instructions

Installation Steps

ESD Grounding: Always wear an anti-static grounding wrist strap connected to cabinet earth before handling the module.

Module Alignment: Slide the MM20 card into the guide rails of an open media slot on the host MS20 or MS30 basic switch.

Mechanical Lock: Press firmly until the backplane connector locks in place. Hand-tighten top and bottom captive thumbscrews on the front faceplate to ensure chassis ground grounding.

Cabling: Attach single-mode duplex SC optical jumpers to Port 1 and RJ45 Ethernet patch cables to Ports 2. 3. and 4.

Hot-Swap Protection: You can safely pull or insert this module while the main switch is powered on without interrupting communications on adjacent switch slots.

5. Fault Diagnosis

Symptom / LEDPossible CauseCorrective Action
Fiber Link LED OffTX/RX fiber pairs crossed, dirty optical face, or distance $>30text{ km}$.Swap SC connector strands (TX$rightarrow$RX), clean fiber end-faces with lint-free wipes, check optical power budget.
Copper Port LED OffLoose RJ45 plug, broken cable, or link partner powered down.Re-seat patch cables, verify connected device status, test cable pinouts.
Module Unresponsive / All LEDs OffBackplane pin misalignment or module loose in slot.Loosen captive screws, extract module, re-align guide rails, push in firmly, and tighten screws.
High Collision / Packet DropsDuplex mismatch on RJ45 ports (e.g., Half vs. Full duplex).Ensure connected field devices are set to Auto-Negotiation or forced to matching speeds.

6. Storage Conditions

Storage Temperature: $-40^circtext{C}$ to $+70^circtext{C}$ in original anti-static protective packaging.

Humidity Control: $< 95%$ relative humidity (non-condensing).

Optical Dust Caps: Keep protective rubber plugs inserted inside the SC fiber port whenever not connected to prevent optical lens contamination.

7. Related Models of the Same Series

Model CodePort ConfigurationTarget Application
MM20-P9T1T1T1SAHH1 × Single-Mode SC Fiber + 3 × RJ45 CopperHybrid uplink + high local copper density
MM20-P9P9T1T1SAHH2 × Single-Mode SC Fiber + 2 × RJ45 CopperDual single-mode fiber ring/redundancy
MM20-M2M2T1T1SAHH2 × Multi-Mode ST Fiber + 2 × RJ45 CopperShort-range multi-mode optical links ($< 5text{ km}$)
MM20-T1T1T1T1SAHH4 × RJ45 Copper (10/100Base-TX)All-copper local switch expansion
MM20-Z6Z6SAHH4 × Fast Ethernet SFP SlotsFlexible transceiver customization
MM20-T1T1T1T1EBH4 × RJ45 Copper (Extended Temp)$-40^circtext{C}$ to $+70^circtext{C}$ extended rating + Conformal Coating


  • نظام التحكم الرقمي في التحفيز الكهربائي BASLER DECS-200
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DIGITAL EXCITATION CONTROL SYSTEM DECS-300
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • ABB Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA PC connection for high-precision data acquisition with ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930 presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System