KONG -Y
NameDescriptionContent
Location:
product
GE Power Conversion P111-6053 Advanced Micro Controller (AMC2)
❤ Add to collection

GE Power Conversion P111-6053 Advanced Micro Controller (AMC2)

GE Power Conversion P111-6053 Advanced Micro Controller (AMC2)

U.S.$14520.00
U.S.$13200.00
U.S.$12540.00
U.S.$12276.00
Weight:0.750KG
Quantity:
(Inventory: 1)
Buy now
Add to cart
Description

GE Power Conversion P111-6053 Advanced Micro Controller (AMC2)


GE Power Conversion P111-6053 Advanced Micro Controller (AMC2)

1. Product Introduction / Overview

The GE Power Conversion P111-6053 is a high-performance industrial embedded controller belonging to the Advanced Micro Controller 2 (AMC2) series, originally designed by Converteam (now GE Power Conversion).

Equipped with an upgraded Intel Pentium-M (1.40 GHz) processor core, the P111-6053 combines high-speed processing with an integrated Serial16+ high-density serial expansion module alongside 5 RJ45 Ethernet communication ports. It is engineered for complex industrial automation, high-speed drive systems, power generation controls, and marine dynamic positioning (DP) architectures requiring both robust multi-channel serial connectivity and advanced processing performance.

2. Technical Table

ParameterTechnical Specification
ManufacturerGE Power Conversion / Converteam
Part Number / Model CodeP111-6053 (AMC2 Series)
Processor CoreIntel Pentium-M @ 1.40 GHz (High-Performance Processor)
System Memory (RAM)256 MB DRAM
Storage Memory256 MB CompactFlash (Solid-State Drive)
Operating SystemEmbedded RTOS / Windows XP Embedded
Input Power Voltage24 V DC ($pm 20%$ tolerance, range: 19.2 V DC to 28.8 V DC)
Nominal Current Consumption~ 1.2 A @ 24 V DC
Ethernet Interfaces5 $times$ RJ45 Communication Ports
Serial Expansion1 $times$ Serial16+ high-density serial interface board
Onboard Serial Ports4 $times$ RS-232 ports
USB Interfaces2 $times$ USB ports with Yamaichi industrial latching
Internal Expansion Slots4 $times$ PMC / PC104+ hardware extension slots
Cooling MethodPassive fanless natural convection
Enclosure Dimensions (W $times$ H $times$ D)234 mm $times$ 206 mm $times$ 120 mm

3. Environmental Tolerance Conditions

Operating Temperature: Rated for passive cooling operation up to 70 °C ambient panel temperature.

Vibration & Mechanical Shock: Compliant with IEC 61131-2 / IEC 1131-2 standards, rated to withstand up to 15 g mechanical shock.

Relative Humidity: 5% to 95% non-condensing.

Enclosure Protection: Designed for installation inside an industrial metal enclosure meeting at least an IP54 protection rating.

Electromagnetic Compatibility (EMC): Heavy industrial immunity rating against fast electrical transients, surges, and high-frequency noise interference.

4. Operating Instructions

Installation & Mechanical Mounting

Mounting: Secure the controller housing via its flange-mount brackets to a flat, grounded metal subpanel inside your control cabinet.

Thermal Clearance: Maintain a minimum of 50 mm (2 inches) of unobstructed space above and below the unit to ensure natural convection airflow across the heatsink fins.

Electrical Wiring & Grounding

Power Connection: Wire a regulated 24 V DC ($pm 20%$) power source to the primary input terminal strip.

Protective Earth (PE): Connect a heavy, low-impedance grounding strap from the chassis grounding stud directly to the main enclosure ground bus bar to eliminate noise on serial data lines.

Startup Sequence

Verify that the system CompactFlash card and Hardware Identity Key are locked securely into their respective slots.

Switch on the 24 V DC power feed and monitor front-panel diagnostic indicators (steady green power LED followed by initialization status lights).

5. Fault Diagnosis

Diagnostic SymptomPotential Root CauseRecommended Action / Solution
Power LED UnlitNo 24 V DC input or blown internal fuse.Verify input voltage levels fall between 19.2 V and 28.8 V DC. Inspect input power wiring.
Boot Failure / Status ErrorCompactFlash card unseated or corrupted software image.Isolate power, re-seat the CompactFlash card, or restore the system flash storage image.
Serial16+ Communication DropLoose multi-pin cabling, incorrect baud rate, or noise interference.Inspect serial connectors, verify shield grounding, and check communication protocol configurations.
Ethernet Link InactiveDamaged network cable, IP subnet conflict, or dead LAN port.Check RJ45 link/activity LEDs; confirm unique static IP configuration across all 5 Ethernet ports.
Over-Temperature WarningRestricted airflow or enclosure ambient temperature exceeding 70 °C.Clear obstruction from the 50 mm thermal gaps; add cabinet ventilation or cooling fans.

6. Related Models of the Same Series

Model CodeCPU ArchitectureNetwork & Expansion ConfigurationsPrimary Application Area
P110-6052600 MHz Celeron-M5 $times$ Ethernet Ports (Base Unit)Standard Base Industrial Controller
P111-6052600 MHz Celeron-M5 $times$ Ethernet + 1 $times$ Serial16+ CardStandard Multi-Serial Field Networks
P112-6052600 MHz Celeron-M5 $times$ Ethernet + 2 $times$ Serial16+ CardsHigh-Density Serial Marine DCS
P110-60531.40 GHz Pentium-M5 $times$ Ethernet Ports (High-Speed Base)High-Performance Base Automation
P111-60531.40 GHz Pentium-M5 $times$ Ethernet + 1 $times$ Serial16+ CardHigh-Performance Serial Automation
P112-60531.40 GHz Pentium-M5 $times$ Ethernet + 2 $times$ Serial16+ CardsHigh-Performance DP & Heavy DCS Processing
P121-6052600 MHz Celeron-M5 $times$ Ethernet + 1 $times$ WorldFIP CardWorldFIP Network Integration

7. Storage Conditions

To ensure electronic component longevity and prevent degradation during storage:

Storage Ambient Temperature: $-40text{ }^circtext{C}$ to $+85text{ }^circtext{C}$.

Storage Relative Humidity: 5% to 95% non-condensing.

Atmospheric Protection: Keep sealed inside anti-static ESD shielding bags within a dust-free storage environment.

Shock Protection: Use foam-lined packing crates to prevent mechanical impacts exceeding the 15 g threshold during transit.


  • CTI 2500 Series® Slice Ethernet Remote I/O System
  • CTI 500 Series® Compact Programmable Automation Control System
  • CTI 2500 Series® Classic Programmable Automation Control System
  • CTI 2500 Series® Bases
  • SHINKAWA VM-25 Condition Monitoring System UPDATED
  • SHINKAWA VM-5 SERIES OPTIONS
  • ABB SACO 64D4 Annunciator unit
  • ABB SPAU 140 C Synchro-check relay
  • HONEYWELL TDC 3000X Advanced Process Manager
  • HONEYWELL ENHANCED MICRO TDC 3000
  • VIBRO-METER VM600Mk2/ VM600 XMx16 + XIO16T extended condition monitoring modules
  • VIBRO-METER VM600Mk2/ VM600 RPS6U rack power supplies
  • VIBRO-METER VM600Mk2/ VM600 ABE056 slimline rack
  • VIBRO-METER VM600Mk2 RLC16Mk2 relay modules
  • VIBRO-METER VM600Mk2 MPC4Mk2 + IOC4Mk2 machinery protection and condition monitoring modules
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • ADLINK cPCI-8168 Advanced 6U CompactPCI 8-axis Motion Controller with One HSL Network
  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK Centralized Motion Controllers PCI-8254/8258
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3o
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • نظام التحكم الرقمي في التحفيز الكهربائي BASLER DECS-200
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DIGITAL EXCITATION CONTROL SYSTEM DECS-300
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • ABB Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA PC connection for high-precision data acquisition with ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET