ABB Circular load cells PFVL141C
ABB Circular load cells PFVL141C
Nominal load (MN):
1.6. 2.5. 3.1. 4.0. 5.0. 6.3. 8.0. 10. 12.5. 14. 16. 18. 20. 22. 25. 28. 31. 35. 40. 45. 50. 51.5. 60
Roll Force load cells
The Millmate Roll Force load cells act as integral parts of the mill stand.
The rock solid Pressductor® load cell design in combination with the intelligent, reliable communication functions are crucial keys to true roll force measurement.
Overview
Due to its low impedance and high output signal power the Millmate Roll Force load cells has an extremely low sensitivity to insulation defects and maintains its measuring accuracy down to a 10kΩ insulation level.
The load cell output signal is calibrated for full interchangeability between load cells of the same type and size.
The various types and the wide load range cover practically all conceivable roll force measurement applications.
PFVL141x QGPR104/102
Accuracy class (% of Fnom) ± 0.5 ± 1.0
Linearity deviation (% of Fnom) ≤± 0.5 ≤± 1.0
Hysteresis (% of Fnom) ≤ 0.2 ≤ 0.2
Repeatability error (% of Fnom) ≤ ± 0.1 ≤ ± 0.05
Compression (mm at Fnom) 0.05 0.05
Calibration error (% of Fnom) 0.1 0.1
Compensation for min. error +20 - +80°C +20 - +80°C
- Zero point drift ≤ ± 0.01%/°C ≤ ± 0.005%/°C
- Sensitivity drift ≤ ± 0.01%/°C ≤ ± 0.01%/°C
Working temperature range -10 - +90°C -10 - +80°C
Max. permitted short-term temp. +110°C +110°C
Storage temperature range -40 - +90°C -40 - +90°C
| IC695RMX128 PACSystems* Redundancy Memory Xchange (RMX) module |
| 330101-00-30-10-02-05 3300 XL 8mm Proximity Probe |
| 81001-450-53-R Inverter module of the thyristor mainboard |
| 330105-02-12-10-02-CN 3300 XL 8 mm Reverse Mount Probes |
| 330730-080-00-CN 3300 XL 11 mm Extension Cable |
| 330130-080-00-00 3300 XL Standard Extension Cable |
| 1C31169G02 Serial link controller |
| 8LSA44.R0022D100-0 8LS synchronous motors |
| IC200PNS001 Profinet network interface unit |
| 8LSA43.R0022D100-0 8LS synchronous motors |
| 1C31166G02 Serial link controller |
| 330130-080-00-05 3300 XL 8mm Proximity Transducer System |
| PP245B 3BSC690126R0001 Process Panel |
| VI702 Model VI702 Vnet/IP Interface Card |
| AIP831-101 Operation keyboard for eight-loop simultaneous |
| A6125 Enclosure piezoelectric vibration monitor |
| XO08R2-A4.O 1SBP260109R1001 Relay output expansion module |
| VT25-373-99/X9 Industrial power module |
Application
ABB has many years of experience of installing load cells in all types of rolling mills.
To achieve the best possible measurement results, certain basic rules must be observed during the installation of the load cell:
The entire force must pass through the load cell.
The force must be measured as close to the source of the force (the roll gap) as possible.