SHINKAWA VM-25 CONDITION MONITORING SYSTEM
Vibration measurement function
[VM-25F01] Recorder Output
(Isolated)
[VM-25F26]
Relay Output
[VM-25F21] Model Code
Input Channel Recorder Output
(Non-isolated) Monitor Output
2ch 2ch 2ch 0ch 0ch VM-25M00-151-01-00-00-00-00
2ch 2ch 2ch 0ch 4ch VM-25M00-151-01-00-21-00-00
2ch 2ch 2ch 4ch 0ch VM-25M00-151-01-00-26-00-00
2ch 2ch 2ch 4ch 4ch VM-25M00-151-01-00-26-21-00
4ch 4ch 4ch 0ch 0ch VM-25M00-151-01-01-00-00-00
4ch 4ch 4ch 0ch 4ch VM-25M00-151-01-01-21-00-00
4ch 4ch 4ch 0ch 8ch VM-25M00-151-01-01-21-21-00
4ch 4ch 4ch 4ch 0ch VM-25M00-151-01-01-26-00-00
4ch 4ch 4ch 4ch 4ch VM-25M00-151-01-01-26-21-00
4ch 4ch 4ch 4ch 8ch VM-25M00-151-01-01-26-21-21
6ch 6ch 6ch 0ch 0ch VM-25M00-151-01-01-01-00-00
6ch 6ch 6ch 0ch 4ch VM-25M00-151-01-01-01-21-00
6ch 6ch 6ch 8ch 0ch VM-25M00-151-01-01-01-26-26
8ch 8ch 8ch 0ch 0ch VM-25M00-151-01-01-01-01-00
GENERAL MONITOR SPECIFICATION
Display : Display measurement value and alarm set value on
7-segment LED.
Vibration measurement function
: Measure vibration of displacement or velocity,
acceleration. (The number of input channels is
selected from Model Code.)
Isolated recorder output
: Output a signal (isolated) proportional to
measurement value (The number of output channels
is selected from Model Code.)
Relay output : Output contact signal from relay.
(The number of output channels is selected from
Model Code.)
Modbus/TCP communication
: Output of data by Modbus protocol
Display
Power supply : Green LED
Normal : On
Stopped : Off
Alarm : Red LED
When DANGER alarm occurs : On
When ALERT alarm occurs : Flashing
Normal : Off
Sequence : Yellow LED
Operating : On
Stopped : Off
DANGER Bypass : Green LED
Operating : On
Stopped : Off
Communication : Green LED
Connected : On
Communicating : Flashing (100msec interval)
Disconnected : Off
Operation Contact Input
Alarm reset(RES.) : Reset the SELF-HOLD Alarm.
Sequence (SEQ.) : Prevent the alarm output during machine startup.
When sequence circuit is in progress, SEQ. lamp on
front panel is lit.
Contact type : Dry contact
Temperature Range
Operating temperature : -20 to +65°C
Storage temperature : -30 to +85°C
Relative humidity : 20 to 90%RH(non-condensing)
Power Supply Voltage
Rated Power Supply Voltage : 24VDC
Power Supply Voltage Range : 22 to 26VDC
Power consumption : 24W(Max.)
Dimensions
Approx. 158.2(W) x 99(H) x 112.85(D) mm (Excluding the projection parts)
Mounting Method
35mm DIN rail
| ABB | 8990001-NK |
| Honeywell | 05701-A-0330 |
| Honeywell | 05701-A-0330 |
| Honeywell | 05701-A-03 |
| SAUTER | AVM234SF132 |
| Emerson | 5X00225G01 |
| Emerson | 1C31224G01 |
| Emerson | 1C31227G01 |
| Emerson | 1C31219G01 |
| Motorola | FLN3566A |
| BHEL | PDP601B |
| SAUTER | AVM234SF132 |
| Allied Telesyn | AT-800S/24 |
| GE | IS200ESYSH3A |
| ABB | 3BHE004468R0021 GDC780BE21 |
| ABB | V28451A-1312131 |
| SEL | SEL-700BT |
| ABB | UC D240 / 3BHE022287R0101 |
| ABB | UNS2980C-Z HIEE205019R0004 |
| A-B | 1797-PS2E2 |
Mass
All full load : Max. 0.9kg(2.0lb)
2CHANNEL VIBRATION MEASUREMENT FUNCTION
Input Points
Input points : 2 channel / slot
Input Transducer*1
Eddy current transducer : FK-202F
Displacement vibration mesurement
Velocity transducer : CV-86, CV-87
Velocity vibration measurement or
displacement vibration measurement
Acceleration transducer : CA-302
Acceleration vibration measurement or
velocity vibration measurement
Other transducer : Voltage signal
Vibration Measurement
Monitor type*1 : Displacement vibration, Velocity vibration,
Acceleration vibration
Monitor range*1 : 1 to 1000
Unit : μm, mils, mm/s, in/s, m/s2, g
Measurement detection : pk-pk、pk、rms
Rectification : Avarage value
Measurement range(AC) : 0 to 9V pk
The input voltage of 100% of F.S. at 100Hz should be
within the range of 39.4mV pk to 9V pk.
Measurement range (DC) : 0 to 22VDC(CV-86, CV-87, CA-302 input)
-22 to 0VDC(FK-202F input)
Input voltage range : -24 to 24VDC
Input impedance : Approx. 50kΩ
Frequency Response*1
4 pole high-pass filter : 2Hz, 5Hz, 10Hz, 20Hz (-3db)
2 pole low-pass filter : 500Hz, 1kHz, 4kHz, 10kHz (-3db)
Sequence Function*1
Used to prevent alarm output that is caused by excessive vibration during
machine startup. Block off the DANGER/ALERT alarm, or switch the alarm
setup value to another number magnified by setup number.
Sequence Setup Value : 0(Block off), 1 to 10 (0.5step)
△ ! WARNING
The sequence function may leave the machine unprotected.
In case the SEQ. magnification number is set up “0“, machine is
unprotected as alarms are disabled.
In case the SEQ. magnification number is set up from 1.5 to 10.0, and
SEQ. function is in effect, alarm set points are multiplied by the set value.
If the number is more than 150% of the monitor range the alarm may not
output.
Suppression Function*1
If the vibration value is less than the setup value, this function is forced to
suppress the measured vibration value and recorder output*2.
Suppression Setup Value*3: 0 to 5% ( 0.1% step)
Burnout Function*1
When an OK alarm occurs (Output defeat function: ON) or at the monitor
startup, the recorder output and the measurement value are controlled as
follows.
Burnout function setting
Burnout setting value Burnout
Recorder output value Mesurement value
Down Scale 0% Equivalent to “0” of the
measurement value
0
Down Scale 0mA / 0V 0V or 0mA 0
Conversion Accuracy
I/O Conversion Accuracy :±1.5% of F.S. at 100Hz at 25°C
±3.0% of F.S. at 100Hz at -20 to +65°C
Output
Recorder(Non-Isolated) Output*1*4 :
Current / Voltage output proportional to
measurement value.
Measurement value of each channel can be
assigned to any output channel of its own slot.
The recorder output gain (1 time or 2 times) can be
changed.
Number of output points : 2 channel
Output range : 4 to 20mADC, 1 to 5V
Max. load resistance : 600Ω (current mood)
Output impedance: Approx. 250Ω (voltage mood)
Monitor output : Input signal is output via buffer amplifier.
Location : BNC(Front) and Terminal block(Bottom)
Output impedance : Approx.100Ω
Output voltage : Max.5mA
Transducer Power Supply :
Proximity transducer (FK-202F) : -24VDC±10% / 25mA Max.
Piezoelectric transducer (CA-86, CA-302)
: +24VDC±10% / 4mA (constant current)
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|
Add: High-tech Software Park, Xiamen City, Fujian Province
Mobile: +86-17750019513(WhatsApp)
Email: yy4291644@gmail.com
Website: https://www.abb-sis.com