KONG -Y
NameDescriptionContent
Location:
product
SHINKAWA VM-741B LOCAL COMMUNICATION &  PHASE MARKER MODULE
❤ Add to collection

SHINKAWA VM-741B LOCAL COMMUNICATION &  PHASE MARKER MODULE

SHINKAWA VM-741B LOCAL COMMUNICATION &  PHASE MARKER MODULE

U.S.$11450.00
U.S.$9560.00
U.S.$9082.00
U.S.$8890.80
Weight:1.020KG
Quantity:
(Inventory: 2)
Buy now
Add to cart
Description

SHINKAWA VM-741B LOCAL COMMUNICATION &  PHASE MARKER MODULE




VM-741B LOCAL COMMUNICATION & 
         PHASE MARKER MODULE
HASE MARKER INPUT  
Input points (tachometer) :  4 points 
Input Impedance : 50kΩ 
Input voltage range : Less than 50Vp-p 
Hysteresis : 1V, 2V, 5V 
Maximum rotation speed : 60,000rpm 
PHASE MARKER INPUT TRANSDUCER  
Proximity transducer : FK-202F, RD-05A 
OPERATION CONTACT INPUT  
RES : Outside reset signal  
SEQ : Sequence signal 
FIL : Filter enable signal 
OUTPUT  
Indicators : DAN LED (Red) 
   On : When DANGER , HH-Speed , or LL-Speed  
            alarm occurs 
    (This indicator lights up when DANGER , HH-Speed , or 
     LL-Speed alarm is output from at least one of the  
     modules stored in the instrument rack .) 
   Off : During normal status  
 ALT LED (Yellow) 
   On : When ALERT , H-Speed , or L-Speed  
            alarm occur 
    (This indicator lights up when ALERT , H-Speed , or  
     L-Speed alarm is output from at least one of the modules  
    stored in the instrument rack .) 
   Off : During normal status  
 SYS-OK LED (Green) 
   On : During normal status 
   Flash : When OK alarm occurs 
    (This indicator flashes when an input abnormality of the  
     phase marker signal is output or an OK alarm is output  
     within the rack.) 
 D-BYP LED (Red) 
   On  : While the DANGER bypass is set 
   Off : During normal status  
  COMM LED (Green) 
   On : Communication is connected 
   Flash : Communication data is being passed 
   Off : Communication is disconnected  
  TRG LED (Yellow) 
   On  : A phase marker pulse is not detected 
   Flash : A phase marker pulse is detected 
OUTPUT  
Monitor output : Input signal is output via a buffer amplifier 
  Location : BNC (Front) and connector (Back)  
  Output Impedance : Approx. 100Ω 
  Output current  : Max. 5mA 
Pulse output : Shaped pulse signal is output via a buffer amplifier. 
  Location : BNC (Front) 
  Signal waveform : 0V (VOL), 5V (VOH) 
  Output Impedance : Approx. 100Ω 
  Output current : Max. 5mA 
Transducer power supply 
 : proximity transducer 
   -24VDC±10% / 25mA Max.  
Contact output : SYS-OK 
   Output points : 1 
   Contact type : Dry contact (SPDT)  
   Enagization method  
    : Normally de-energized or 
      Normally energized field changeable 
   Contact capacity : 250VAC/5A, 30VDC/5A 
ALARM  
Alarm reset : AUTO-RESET or SELF-HOLD field changeable. 

SAUTERAVM234SF132
Emerson5X00225G01
Emerson1C31224G01
Emerson1C31227G01
Emerson1C31219G01
MotorolaFLN3566A
BHELPDP601B
SAUTERAVM234SF132
Allied TelesynAT-800S/24
GEIS200ESYSH3A
ABB3BHE004468R0021 GDC780BE21
ABBV28451A-1312131
SELSEL-700BT
ABBUC D240 / 3BHE022287R0101
ABBUNS2980C-Z HIEE205019R0004


PROGRAMMABLE INDICATOR COMMUNICATION  
Network : RS-485 
Protocol : Modbus/RTU 
Connector : 5-pin connector (Back side of rack) 
MCL VIEW (VM-771B) COMMUNICATION  
Network : Ethernet 100Base-TX 
Protocol : TCP/IP 
Connector : RJ-45 (Back side of rack) 
DEVICE CONFIG (VM-772B) COMMUNICATION  
Network : USB 2.0/1.1 
Connector : Type-B (Front side of rack) 

SECURITY FUNCTION*1  
Network : Ethernet 100Base-TX 
Protocol : TCP/IP 
Connector : RJ-45(Back side of rack) 
Filter function : None(non-compliant Security Function) 
Off(Filter OFF : Maintenance only) 
On(Filter ON : In Operation) 
Client MAC Address : MAC Address of PC for MCL View 
Client IP Address   : IP Address of PC for MCL View 
 *1 About the Security Function  
  ・When selecting the presence of "security function", other networks  
    (VM-742B: Fieldbus(Modbus / TCP), Analysis software communication  
(TCP / IP)) to unify security policies are also " Please select the presence of  
security function ".  
 ・Custom setup of "Security function" can’t be order.  
 ・Select "Security Function", you can meet a global certification program  
(Achilles Certification Level 2) that proves to have a certain network 
robustness.  
 ・Achilles is a registered trademark of GE Digital. 
ENVIRONMENTAL CONDITION  
Operating temperature : 0 to +65°C 
Operating temperature at explosion proof construction 
   : 0 to +60°C 
Storage temperature  : -30 to +85°C 
Relative humidity   : 20 to 95%RH (non-condensing) 
POWER CONSUMPTION  
Module alone : Less than 15W  
MATERIAL and FINISH  
Face plate : ABS (Black) 
Sheet : Polyester tough top (Gray) 
Base plate : Alminium alloy (Silver) 
MASS  
Body : Max. 1.0 kg (2.2 lb) 
ACCESSORY SPECIFICATION CODE / IDENTIFIED BY TB□  
Code Accessory Quantity 
(Part Code) 
/TB1 Phase Marker input terminal block plug (15pin)  
FRONT-MC-1.5/15-STF-3.81(PHOENIX CONTACT) 
1piece  
(7072NAB) 
 Phase Marker input terminal block plug (6pin) 
FRONT-MC-1.5/6-STF-3.81(PHOENIX CONTACT) 
1piece  
(7072NAC) 
 SYSTEM-OK output terminal block plug (6pin) 
FRONT-MC-1.5/6-STF-3.81(PHOENIX CONTACT) 
1piece  
(7072NAC) 
 Contact input terminal block plug (6pin) 
FRONT-MC-1.5/6-STF-3.81(PHOENIX CONTACT) 
1piece  
(7072NAC) 
/TB2 SYSTEM-OK output terminal block plug (6pin) 
FRONT-MC-1.5/6-STF-3.81(PHOENIX CONTACT) 
1piece  
(7072NAC) 
 Contact input terminal block plug (6pin) 
FRONT-MC-1.5/6-STF-3.81(PHOENIX CONTACT) 
1piece  
(7072NAC) 
Note) *1 D-sub plugs and hoods are not included in this code. Please make  
necessary arrangement separately, if required. 
*2  When individually ordering specify the parts code, it is require 
  to arrange for a necessary amount. 


  • ABB SACO 64D4 Annunciator unit
  • ABB SPAU 140 C Synchro-check relay
  • HONEYWELL TDC 3000X Advanced Process Manager
  • HONEYWELL ENHANCED MICRO TDC 3000
  • VIBRO-METER VM600Mk2/ VM600 XMx16 + XIO16T extended condition monitoring modules
  • VIBRO-METER VM600Mk2/ VM600 RPS6U rack power supplies
  • VIBRO-METER VM600Mk2/ VM600 ABE056 slimline rack
  • VIBRO-METER VM600Mk2 RLC16Mk2 relay modules
  • VIBRO-METER VM600Mk2 MPC4Mk2 + IOC4Mk2 machinery protection and condition monitoring modules
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • VIBRO-METER VM600Mk2 CPUMMk2 + IOCNMk2 rack controller and communications interface module
  • ADLINK cPCI-8168 Advanced 6U CompactPCI 8-axis Motion Controller with One HSL Network
  • ADLINK PCI/PCIe-7300A, cPCI-7300 32-CH 80 MB/s High-Speed Digital I/O Cards
  • ADLINK cPCI-7248/7249R 48-CH DIO & Timer/Counter Cards
  • ADLINK PCI-7230/7233/7234. LPCI/LPCIe/cPCI-7230 32-CH Isolated DIO Cards
  • ADLINK cPCI-6965 Series Value 6U CompactPCI® Intel® Core™2 Duo
  • ADLINK cPCI-6910 Series 6U CompactPCI® Dual-Core Intel® Xeon® Processor LV / ULV Universal Blade
  • ADLINK CPCI-6670 6U CompactPCI Low Power Pentium® III SBC
  • ADLINK cPCI-6625/6 Series6U CompactPCI® PlusIO blade with Intel® Core™ i7/i3 Processor
  • ADLINK 3U CompactPCI CPU Modules
  • ADLINK CM-435 Extreme Rugged™ PC/104 Single Board Computer
  • ADLINK Centralized Motion Controllers PCI-8254/8258
  • ADLINK NuPRO-E43 PICMG® 1.3 Full-Size LGA1151 with 6th/7th Generation Intel® Core™ i7/i5/i3o
  • ADLINK DLAP-211-JNX/DLAP-211-JT2/ DLAP-211-Nano
  • نظام التحكم الرقمي في التحفيز الكهربائي BASLER DECS-200
  • Hirschmann RS30-1602O6O6SDAE compact OpenRail managed Ethernet switches
  • Hirschmann RS30-0802O6O6SDAE Ethernet switch
  • Hirschmann RS20-1600T1T1SDAE Management-type Ethernet switch
  • Hirschmann OCTOPUS 24M Limited Availability/Passive
  • Hirschmann MSP30-24040SCZ9MRHHE3A
  • Hirschmann MAR1040-4C4C4C4C9999SMMHRHHXX.X. Gigabit Ethernet Switch configurator
  • Hirschmann Industrial Ethernet Rail Switch SPIDER II, SPIDER II Giga, SPIDER II PoE
  • Hirschmann Industrial Ethernet Firewall EAGLE One
  • Hirschmann Industrial Security Router EAGLE20/30
  • Hirschmann Description and operating instructions RS2-xTX/xFX EEC
  • Basler Electric DIGITAL EXCITATION CONTROL SYSTEM DECS-300
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric GENERATOR PROTECTION SYSTEM BE1-GPS100
  • Jaquet FT3000 Speed measurement system
  • Hirschmann Industrial Ethernet Ruggedized Switch MACH1000 Family
  • Basler Electric BESTCOMSPlus®
  • ETEL AccurET MODULAR 300 EA-P2M-300-xxxxxA controller
  • Basler Electric ES Series Protection Relays
  • ABB Multifunction Protection and Switchbay Control Unit REF542plus
  • EMERSON AMS 2140 Machinery Health Analyzer
  • Hirschmann Industrial Ethernet Rail Switch RS20 Basic Family
  • GE Grid Solutions P40U Px40 USB Adaptor
  • ABB ontinuous Gas Analyzers AO2000 Series AO2040CU Ex Central Unit in Category 2G
  • ABB Advance Optima AO2000 Series Continuous gas analyzers Models AO2020. AO2040
  • ABB Advance Optima Module Uras 14
  • SAACKE control optimization
  • SAACKE se@vis efficiency monitor
  • SAACKE se@vis pro
  • SAACKE se@vis eco
  • SAACKE se@vis compact
  • HIRSCHMANN Industrial ETHERNET Switch MICE MS20/MS30
  • HIRSCHMANN MICE Media modules
  • Kongsberg GL-10 Level Switch
  • B&R ACOPOSinverter P74 frequency converter
  • Beckhoff CX2020 | Basic CPU module (service phase)
  • Beckhoff CX1010 | Basic CPU module (service phase)
  • Beckhoff CX5120 | Embedded PC with Intel Atom® E3815
  • Beckhoff CP69xx-xxxx-0010 | Economy built-in Control Panel with DVI/USB Extended interface
  • Beckhoff CP29xx-0000 | Multi-touch built-in Control Panel with DVI/USB Extended interface
  • SAACKE Monoblock Rotary Cup Burner SKVJ-M
  • ABB Plantguard Fault Tolerant Technology Architecture and Software
  • OMRON H8PR-8/H8PR-8P H8PR-16/H8PR-16P H8PR-24/H8PR-24P Rotary Positioner
  • ABB PFSA107-Z42 DTU Stressometer Digital Transmission Unit
  • Nidec Mentor MP
  • IBA PC connection for high-precision data acquisition with ibaNet-E
  • IBA FO Connection to Reflective Memory
  • IBA FO Connection to Siemens Systems
  • IBA Interface Cards For Fiber Optic Connections
  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044