IBA ibaBM-DP Bus monitor for PROFIBUS
ibaBM-DP: Bus monitor for PROFIBUS
Connectors for 2 PROFIBUS lines up to 12 Mbit/s
Sniffer function for interference free acquisition of the cyclic master slave communication (DP-V0)
Up to 8 or 16* active slaves can be configured
Acquisition of up to 244 Bytes per active slave
Flexible configuration of sampling rate, data format and data volume
Support of ibaNet protocol 32Mbit Flex
Additional options for special fields of application: redundancy*-, simulation*-, mirror*-, mapping*- and P2P mode
Scope of delivery
After unpacking, check the delivery for completeness and possible damages.
The scope of delivery comprises:
ibaDAQ-C device
Covering caps for USB and Ethernet
2-pin connector with spring terminals (digital input, to initiate shutdown by UPS)
3-pin connector with spring terminals (voltage supply)
"iba Software & Manuals" data medium
Safety instructions
Intended use
The device is an electrical apparatus. It is only allowed to use the device for the following
applications:
Measurement acquisition
Applications with iba products (ibaPDA, and others)
The device must only be used as described in chapter 10 Technical data.
System requirements
Hardware
For operation
Power supply 24 V DC ± 10%, 1 A (when connecting 2 USB devices, e. g. hard
disks)
For device parameterization and operation
Monitor (connection to DisplayPort), mouse and keyboard (connection to USB
ports)
or
ibaPDA client via network link
Mounting on a DIN rail
1. Insert the DIN rail clip on the rear side of the device on top in the DIN rail, push the
device down backwards and let it lock into the DIN rail. If necessary, use a slot screw
driver to pull down the lug of the DIN rail clip.
2. Once fixed, connect the 24 V DC power supply with the right polarity.
3. Connect the Ethernet cable(s)
Dismounting
1. Switch off the device.
2. Remove all cables.
3. Grasp the bottom of the device with one hand and
insert a slot screwdriver into the lug of the DIN rail
clip.
4. Pull the screwdriver upwards like a lever to unlock
the DIN rail clip.
5. Grasp the bottom of the device, pull it forward and lift
it upwards.
First configuration
Setup via network
In the factory setting of the network interface, DHCP is active (rotary switch S1 position
= 1). Thus, an IP address is automatically assigned to ibaDAQ-C, as soon as the device
is connected to a network with a DHCP server.
If the IP configuration is successful, ibaDAQ-C can be accessed via the host name
daq-c-, e. g. daq-c-000002.
If the network does not have a DHCP server, ibaDAQ-C can be set to fixed IP addresses
via the rotary switch S1 position = 2:
Network interface X21:
192.168.1.1
Network interface X22:
192.168.1.2

ibaPDA client
If not already existing, please install ibaPDA on the system you have selected for the
configuration of ibaDAQ-C. The installation file can be found on the data medium “iba
Software & Manuals” in the directory „01_iba_SoftwareibaPDA“.
Start the ibaPDA client.
Click on the icon to start the dialog “ibaPDA server selection” and enter the host
name or the IP address of ibaDAQ-C as address. By default, the port number is 9170. If
ibaDAQ-C is already in the list of servers, you can also select the device there.
Exit the dialog with.
Provided that the ibaPDA versions match, ibaPDA directly connects to the ibaDAQ-C
system. If the ibaPDA versions do not match, you will be requested to install the suitable
ibaPDA version.
To further configure the system, proceed as described in chapter 9.
6.3.1.2 Remote Desktop
Open the Remote Desktop Connection on the system you want to configure ibaDAQ-C.
You can find this in the Windows task bar under “Accessories”.
There is another option to open the Remote Desktop Connection:
Press the keys+and enter “mstsc“ in the field.
If you are requested to enter login information, use the information given in chapter 7.8.
Start the ibaPDA client from the Windows Start menu.
For further configuration, proceed as described in chapter 9.
6.3.2
Set up via monitor, keyboard and mouse
Connect a monitor to the DisplayPort connection of ibaDAQ-C. If necessary use an
adapter.
Connect a keyboard and a mouse to the USB ports of ibaDAQ-C.
If required, log in to the system. You can find the login data in chapter 7.8.
Start the ibaPDA client from the Windows Start menu.
For further configuration, proceed as described in chapter 9
| REF542 REM543 Machine Terminals |
| IS200WROBH1A WROB RELAY FUSE AND POWER SENSING BOARD |
| 1TGE120021R8211 Motor and Feeder Control Unit |
| MKD071B-061-KG1-KN MKD Synchronous Motors |
| IS200TBAIH1C ANALOG INPUT TERMINAL BOARD |
| IS200STAIH2A SIMPLEX ANALOG INPUT TERMINAL BOARD |
| IS200REBFH1BBA ISBus Extender board |
| REM543CG214AAAA REM543 Machine Terminals |
| XVH-340-57MPI-1-10 5.7 COLOUR RESISTIVE TOUCH SCREEN |
| PFEA112-65 Tension Electronics PFEA111-20 |
| VME162PA-344SE-2G VME162PA-344SE Embedded Controller |
| 1TGE120021R0810 Motor and Feeder Control Unit |
| XV252-57CNN-1-10 5.7 COLOUR RESISTIVE TOUCH SCREEN |
| SERVOSTAR 406A-C Digital Servo Amplifier S400 |
| REX521GHHPSH50G Feeder protection relay REX 521 |
| 3500/33-01-01 3500/33 16-Channel Relay Module |
| CC-PFB402 CC-PFB401 Offers Unmatched Fieldbus Benefits |
| NFAR181-SS0 Turbomachinery Controller |
| IS210AEBIH1BAB wind turbine control card |
| IS200WETCH1AAA Mark VI printed circuit board |
| 1TGE120021R8311 Motor and Feeder Control Unit |
| PFEA111-20 3BSE050090R20 Tension Electronics PFEA111-65 |
| 2094-BC02-M02-M Kinetix 6200 component |
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|
Add: High-tech Software Park, Xiamen City, Fujian Province
Mobile: +86-17750019513(WhatsApp)
Email: yy4291644@gmail.com
Website: https://www.abb-sis.com