KONG -Y
NameDescriptionContent
Location:
product
IBA ibaBM-eCAT  Bus monitor for EtherCAT
❤ Add to collection

IBA ibaBM-eCAT Bus monitor for EtherCAT

IBA ibaBM-DP Bus monitor for PROFIBUS

U.S.$6980.00
U.S.$5670.00
U.S.$5386.50
U.S.$5273.10
Weight:1.290KG
Quantity:
(Inventory: 2)
Buy now
Add to cart
Description

IBA ibaBM-DP Bus monitor for PROFIBUS


ibaBM-eCAT: Bus monitor for EtherCAT

Integration into the EtherCAT bus next to the MainDevice

To be used for interference free recording of the communication between MainDevice and SubDevice (sniffer function)

Optional configurable as active EtherCAT SubDevice

Acquisition and recording of up to 512 analog and 512 digital signals in each signal direction (up to 4060 Bytes)

Support of ibaNet protocol 32Mbit Flex

Status display

ON/OFF switch S11

Connector for 24 V power supply X14

Rotary switch S1

Display (operating status, user-defined)

Network port X21

Network port X22

USB 3.0 port X24

USB 2.0 port X25

Monitor connection X26

Display elements

7.2.1 Operating status

The operating state of the device is indicated by colored LEDs.

LED Color Status Description

Run

Green Off Device down, no power supply

Hardware error, controller stopped

Flashing Ready

On Device starts up / shuts down

Yellow/

orange

On Operating voltage present, device off

PDA Yellow Flashing  Updating

On ibaPDA server running

White  Without function

Error Red Off No error

On Hardware error

Operating state and user-defined displays

Multi-colored LEDs (Lic and Dat) indicate the status of the license and data recording. It

is possible to assign signals to 2 multi-colored LEDs in ibaPDA to display user-defined

states.

LED Color Status Description

Lic

Yellow  Demo licenses on dongle released

Green  Dongle OK

Red  No dongle or no license

Dat Off  No data recording configured

Yellow  Waiting for start trigger

Green  Recording data

Red  Data recording interrupted/stopped

PDA1 Yellow

Green  User-defined display

Red

Off

PDA2

Yellow

Green  User-defined display

Red

Off

1TGE120021R6010   Communication Gateway
IC695CPE330 IC695CPE330CA-AAAG RX3i 1GHz   64MB CPU w/Ethernet
2094-BC02-M02-S Kinetix 6000 Integrated   Axis Module (IAM)
85UVF1A-1QDK3 85UVF1A-1QD Integrated   Flame Scanner with Internal Flame Relay
VT-HNC100-1-23/M-08-0-0 servo controller
PPC380AE01 HIEE300855R0001 Digital input   card
1900/65A-00-01-01-00-00General Purpose   Equipment Monitor
GDS1173-CC-NFNF POWER INTERFACE BOARD
1756-L75K 1756 ControlLogix Controllers
F650-B-A-B-F-1-G-1-HI-P-E Multi-line   feeder protection and interval controller
F650-B-A-B-F-1-G-0-HI-P-E Multi-line   feeder protection and interval controller
MDX60A0300-503-4-00 Servo driver
MVME147-023 VMEbus single-board computer
80026-172-24-R Gate module commutator   thyristor
DS3820FEDA1C1F FIELD EXCITER 50 AMP POWER   RESET
PXLE-1085 50 Hz/60 Hz PXI Chassis
FC-PSU-UN22450U V1.0 POWER SUPPLY   HONEYWELL
8577-1362 Controller transformer
IS200EPSMG2AED Power Supply Module
REF620 NBFNAAAAABC1BNN1XF dedicated   feeder IED perfectly
TK-3E 177313-01-02 TK3 Proximity System   Test Kit
1900/65A-00-01-01-00-00 General Purpose   Equipment Monitor
IS220PDIOH1AE I/O pack module
PXIE-4468 PXI Sound and Vibration Module

Operating elements

ON/OFF switch S11

By switching the device off and on again, the supply voltage is disconnected and re

connected and the device is rebooted. There are different ways to shut down or switch

off the running device:

 Press briefly: system shuts down

 Press and hold (> 5 s): system switches off (no controlled shut-down)

Rotary switch S1

The S1 rotary switch is used to specify IP address settings:

Position

Description

0  User-defined settings can be assigned for the interfaces X21 and X22.

The IP addresses can be configured in ibaPDA or in the system settings.

1

2

DHCP active for X21 and X22 (factory setting)

fixed IP addresses

X21: 192.168.1.1

X22: 192.168.1.2

3…F

Not allowed

It is also possible to select different address assignment methods for the two interfaces

X21 and X22. Example:

 X21 = Interface for the IT network, DHCP is active

 X22 = Interface for the process network with fixed IP address 192.168.121.2

Procedure:

1. First, set switch S1 to position 1 and establish a connection between the ibaPDA

client and ibaDAQ-C. To do so, start the ibaPDA client on your PC and follow the

steps in chapter 9.1.

2. Set switch S1 to position 0.

3. Open the I/O Manager in ibaPDA, select the node ibaDAQ-C and switch to the "Info”

tab.

Assign the appropriate settings for the network interfaces. For the above example,

select "Use DHCP" for X21. For X22. uncheck "Use DHCP" and enter a fixed IP ad

dress that matches your network. Click onto activate the settings.

Communication interfaces

Network interface X21. X22

The device can be integrated into Ethernet networks via the network interfaces X21 and

X22. Settings for the IP address can be made at the S1 rotary switch.

 See chapter 7.3.2

DHCP is activated in the factory settings.

It is also possible to connect ibaNet-E capable devices via these interfaces.

USB ports

 USB 2.0 (X25): 480 Mbit/s

 USB 3.0 (X24): up to 5 Gbit/s

DisplayPort X26

DisplayPort to connect a monitor. If the monitor does not have a DisplayPort, an adapter

can be used, e. g. CSL - 3in1 DisplayPort to VGA + HDMI + DVI adapter.

Digital input X5

You can connect an input signal at the bottom of the device, bipolar and electrically iso

lated.

The X5 input can be used to initiate a safe shut-down when a trigger signal indicates that

the voltage supply is interrupted.

The switching threshold of the input is >4 V and the level must not exceed 60 V to prevent

damage to the device.



  • IBA Field and Drive Buses
  • IBA ibaPADU-S Modular System
  • IBA ibaMAQS
  • STUCKE SYMAP®ARC
  • STUCKE SYMAP®R
  • STUCKE SYMAP®Compact
  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930 presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • Configuration for AMS 6500 Protection Monitors
  • EMERSON DeltaV™ M-series Traditional I/O
  • EMERSON DeltaV™ SQ Controller
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • ABB Ethernet Modules EI 802F
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • Control product - Soft starter PST/PSTB (Intelligent Type) ABB