Mailboxes: The VMEbus interface provides four 32-bit

mailboxes, which are accessible from both the microprocessor

and the VMEbus providing interprocessor communication. The

mailboxes have the ability to interrupt the microprocessor when

accessed by VMEbus.

Interrupt Handler: The interrupt handler monitors, and can be

programmed to respond to any or all VMEbus IRQ* lines. All

normal-process VMEbus-related interrupts can be mapped to

PCI INTA# or SERR# interrupts. These include:

Mailbox interrupts

VMEbus interrupts

VMEbus interrupter IACK cycle (acknowledgment of

VMIVME-7750 VMEbus-issued interrupts)

All error processing VMEbus-related interrupts can be mapped

to PCI INTA# or SERR#. Note: PCI SERR# initiates a SBC NMI.These include:

ACFAIL* interrupt

BERR* interrupt

SYSFAIL* interrupt

The interrupt handler has a corresponding STATUS/ID register

for each IRQ* interrupt. Once the handler receives an IRQ*, it

requests the VMEbus and, once granted, it performs an IACK

cycle for that level. Once the IACK cycle is complete and the

STATUS/ID is stored in the corresponding ID register, an

appropriate interrupt status bit is set in an internal status

register, and a PCI interrupt is generated. The PCI interrupt can

be mapped to PCI INTA# or SERR#.

Interrupter: Interrupts can be issued under software control on

any or all of the seven VMEbus interrupt lines (IRQ7* to IRQ1*). A

common ID register is associated with all interrupt lines. During

the interrupt acknowledge cycle, the interrupter issues the ID to

the interrupt handler.

The interrupter can be programmed to generate a PCI INTA# or

SERR# interrupt when a VMEbus interrupt handler

acknowledges a software-generated VMEbus interrupt.

Byte Swapping: The Intel 80x86 family of processors use little

endian format. To accommodate other VMEbus modules that

transfer data in big-endian format such as the 680x0 processor

family, the VMIVME-7750 incorporates byte-swapping

hardware. This provides independent byte swapping for both

the master and slave interfaces. Both master and slave

interface byte swapping are under software control.

The VMIVME-7750 supports high throughput DMA transfers of

bytes, words, and longwords in both master and slave

configurations.

If endian conversion is not needed, we offer a special “bypass”

mode that can be used to further enhance throughput. (Not

available for byte transfers.)

Master Interface: MA32:MBLT32:MBLT64

(A32:A24:A16:D32:D16:D8 (EO):BLT32)

The VMEbus master interface provides nine separate memory

windows into VMEbus resources. Each window has separate

configuration registers for mapping PCI transfers to the VMEbus

(that is, PCI base address, window size, VMEbus base address,

VMEbus access type, VMEbus address/data size, etc.). The

maximum/minimum window sizes for the nine windows are as

follows:

Window

Minimum Size

0. 4

Maximum Size

4 Kbyte

1 to 3. 5 to 7

4 Gbyte

64 Kbyte

Special Cycle

4 Gbyte

64 Mbyte

64 Mbyte

Slave Interface: Memory Access

SAD032:SD32:SBLT32:SBLT64

(A32:A24:A16:D32:D16:D8 (EO): BLT32)

The VMEbus slave interface provides eight separate memory

windows into PCI resources. Each window has separate

configuration registers for mapping VMEbus transfers to the PCI

bus (that is, VMEbus base address, window size, PCI base

address, VMEbus access type, VMEbus address/data size, etc.).

The maximum/minimum window sizes for the eight windows

are as follows:

Window

Minimum Size

0. 4

Maximum Size

4 Kbyte

4 Gbyte

1 to 3. 5 to 7

64 Kbyte

4 Gbyte

In addition, each window can be programmed to operate in

coupled or decoupled mode. In decoupled mode, the window

utilizes a write-posting FIFO and/or a read prefetching FIFO for

increased system performance. In coupled mode, the FIFOs are

bypassed and VMEbus transactions are directly coupled to the

PCI bus (that is, transfers on VMEbus are not completed until

they are completed on the PCI bus).

Enhanced Bus Error Handling: Enhancements over the

Universe chip’s bus error handling features are provided. A latch

and register are provided to allow the SBC to read the VMEbus

address that caused the bus error in all modes. The Universe

chip’s support is limited to decoupled mode.

Support for bus cycle timeout and assertion of bus error is

provided. The board may be configured to assert bus error upon

timeout regardless of its status as system controller. The

Universe chip asserts bus error only if it is system controller. In

addition, this board may be configured to assert an interrupt

upon bus cycle timeout.

Operating System and Software Support

The VMIVME-7750 provides embedded features beyond PC/AT

functionality. These features are supported by GE Fanuc

Embedded Systems software products aimed at developers

who are incorporating GE Fanuc Embedded Systems SBCs, I/O

boards, and workstations into systems. Windows XP/Windows

2000 and VxWorks are the most common operating systems

supported by GE Fanuc Embedded Systems software products.

Windows XP/Windows 2000: The IOWorks® software family is a

set of software components that can work together or

separately to provide a total development environment for any

application in a Windows XP/ Windows 2000 OS.

VMISFT-9422 VMEbus Access™ for Windows XP/Windows

2000: The VMEbus Access product is specifically designed for

  • SEL SEL-2533 Annunciator
  • SEL SEL-2523 Annunciator Panel
  • SEL SEL-2522 Alarm Panel
  • SEL SEL-2516 Rack-Mount Remote I/O Module
  • SEL SEL-2515 Remote I/O Module
  • SEL SEL-2507 High-Speed Remote I/O Module
  • SEL SEL-2506 Rack-Mount Remote I/O Module
  • SEL SEL-2505 Remote I/O Module
  • SEL SEL-3401 Digital Clock
  • SEL SEL-9929 Satellite-Synchronized Clock Display Kit
  • SEL SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver
  • SEL SEL-3400 IRIG-B Distribution Module
  • SEL SEL-2401 Satellite-Synchronized Cloc
  • SEL SEL-2407 Satellite-Synchronized Clock
  • SEL SEL-2488 Satellite-Synchronized Network Clock
  • SEL SEL-5051/5052 Client/Server Network Management System (NMS) Software
  • SEL SEL-5056 Network Management System (NMS)
  • SEL SEL-3031 Serial Radio Transceiverceiver
  • SEL SEL-3061 Cellular Router
  • SEL ICON Integrated Communications Optical Network
  • SEL SEL-3622 Security Gateway
  • SEL SEL-3620 Ethernet Security Gateway
  • SEL SEL-3620 Ethernet Security Gateway
  • SEL SEL-3610 Port Server
  • SEL SEL-2730U Unmanaged 24-Port Ethernet Switch
  • SEL SEL-2725 Five-Port Ethernet Switch
  • SEL SEL-2744 Ethernet Switch
  • SEL SEL-2743 Ethernet Switch
  • SEL SEL-2742 Ethernet Switch
  • SEL SEL-2741 Ethernet Switch
  • SEL SEL-2731 Ethernet Switch
  • SEL SEL-2902 RJ45 to DB-9 Adapter Panel
  • SEL SEL-3390S8 Serial Adapter Card
  • SEL SEL-3390E4 Network Adapter Card
  • SEL SEL-3390T Time and Ethernet Adapter Card
  • SEL SEL-3360 Computing Platform
  • SEL SEL-3355 Computing Platform
  • SEL SEL-5703 Synchrowave Monitoring
  • SEL SEL-5705 Synchrowave Reports
  • SEL Metering Software Solutions
  • SEL SEL-T35 Time-Domain Power Monitor
  • SEL SEL-735 Power Quality and Revenue Meter
  • SEL SEL-TWFL Dual Traveling-Wave Fault Locator and 12-Channel MHz Recorder
  • SEL SEL-5035 acSELerator Diagram Builder Software
  • SEL SEL-5033 acSELerator RTAC Software
  • SEL SEL-2411P Pump Automation Controller
  • SEL SEL-2411 Programmable Automation Controller
  • SEL SEL-3560 Real-Time Automation Controller (RTAC)
  • SEL SEL-3555 Real-Time Automation Controller (RTAC)
  • SEL SEL-3350 Computing Platform
  • SEL SEL-3530-4 Real-Time Automation Controller (RTAC)
  • SEL SEL-3505/3505-3 Real-Time Automation Controller (RTAC)
  • SEL Real-Time Automation Controller (RTAC)
  • SEL SEL-2414 Transformer Automation Controller (TAC)
  • SEL SEL-734B Advanced Monitoring and Control System
  • SEL SEL-734W and LINAM WCS
  • SEL SEL-2431 Voltage Regulator Control
  • SEL SEL-5601-2 Synchrowave Event Software
  • SEL SEL-5032 acSELerator Architect Software
  • SEL SEL-5030 acSELerator QuickSet Software
  • SEL SEL-751A Feeder Protection Relay
  • SEL SEL-751A Feeder Protection Relay
  • SEL SEL-2440 DPAC Discrete Programmable Automation Controller
  • SEL SEL-2240 Axion
  • SEL SEL-401 Protection, Automation, and Control Merging Unit
  • SEL SEL-TMU TiDL Merging Unit
  • SEL SEL-700BT Motor Bus Transfer Relay
  • SEL SEL-849 Motor Management Relay
  • SEL SEL-3790 Low-Voltage Divider Module
  • SEL SEL-710-5 Motor Protection Relay
  • SEL SEL-487V Capacitor Bank Protection, Automation, and Control System
  • SEL SEL-351RS Kestrel Single-Phase Recloser Control
  • SEL SEL-651RA Recloser Control
  • SEL SEL-651R Advanced Recloser Control
  • SEL SEL-551C Overcurrent/Reclosing Relay
  • SEL SEL-351S Protection System
  • SEL SEL-851 Feeder Protection Relay
  • SEL SEL-451 Protection, Automation, and Bay Control System
  • SEL SEL-751 Feeder Protection Relay
  • SEL SEL-311C Transmission Protection System
  • SEL SEL-387L Line Current Differential Relay
  • SEL SEL-311L Line Current Differential Protection and Automation System
  • SEL SEL-787L Line Current Differential Relay
  • SEL SEL-421 Protection, Automation, and Control System
  • SEL SEL-9L Line Relay
  • SEL SEL-411L Advanced Line Differential Protection, Automation, and Control System
  • SEL SEL-587Z High-Impedance Differential Relay
  • SEL SEL-7251 Electromechanical Direct-Replacement Assemblies
  • SEL SEL-787Z High-Impedance Differential Relay and SEL-HZM High-Impedance Module
  • SEL SEL-487B Bus Differential and Breaker Failure Relay
  • SEL SEL-387 Current Differential and Overcurrent Relay
  • SEL SEL-387A Current Differential and Overcurrent Relay
  • SEL SEL-2600 RTD Module
  • SEL SEL-387E Current Differential and Voltage Relay
  • SEL SEL-787-2/-3/-4 Transformer Protection Relay
  • SEL SEL-487E Transformer Protection Relay
  • SEL SEL-2664S Stator Ground Protection Relay
  • SEL SEL-300G Generator Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL SEL-400G Advanced Generator Protection System
  • SEL SEL-T400L Time-Domain Line Protection
  • ADLINK SEL-T401L Ultra-High-Speed Line Relay
  • ADLINK Multi-Function DAQ PCI-9222/9223
  • ADLINK PICMG Single Board Computers NuPRO-A40H
  • ADLINK HSL-4XMO  HSL-4XMO-TB-D103  HSL-4XMO-CD-N-006
  • ADLINK industrial computer motherboard NuPRO-965DV
  • ADLINK PCI-7442 switch card Digital I/O
  • ADLINK PCI-7260 Digital I/O
  • ADLINK PICMG Single Board Computers NuPRO-852
  • ADlink 6U CompactPCI 2.0 Blades cPCI-6840
  • Adlink PICMG Single Board Computers NuPRO-935A
  • ADLINK ADLINK NuPRO-841 REV:1.0 PICMG Single Board Computers
  • ADLINK PCI-8254 / PCI-8258 DSP-based 4/8-axis Advanced Motion Controllers
  • ADLINK NUPRO-780 PICMG Single Board Computers
  • ADLINK USB-7230/7250 Isolated USB Digital I/O Modules
  • ADLINK USB-7230/7250 Isolated USB Digital I/O Modules
  • Adlink Technology 51-37111-0C1 cPCI-R8217 cPCI-R3700A PCB Interface Card
  • ADLINK DPAC-3020-11(G) Embedded PC Automation Controller
  • ADLINK NuPRO-840 PICMG 1.0 industrial Single Board
  • Adlink 6U CompactPCI 2.0 Blades cPCI-6965
  • ADLINK PCI-9114DG Multi-Function DAQ Card
  • Adlink NuPRO-E43 PICMG Single Board Computers
  • Adlink PCI-7856 Distributed Motion Control
  • ADLINK Mini-ITX Embedded Boards MI-965
  • ADLINK NuPRO-E340 ICMG Single Board Computers
  • ADLINK NuPRO-595 Series Full-Size PICMG 1.0 SBC
  • ADLINK PCIe-GIE64+ / PCIe-GIE62+ 4 / 2-CH PCI Express® Power over Ethernet Frame Grabbers
  • ADLINK CPCI-6910AM-M1G 6U Dual Core Xeon CompactPCI Universal SBC