Compact FBM240. Redundant with Readback, Discrete

Output and Discrete Input Module

Overview

The Compact FBM240is an 8 channel input and 8 channel output Foxboro™ DCS

Fieldbus Module (FBM) available as a single or redundant module. A redundant pair

of the modules combine to provide redundancy at the FBM level, with field I/O wired to

one commontermination assembly (see Figure 1). Each module independently holds

the output(s) at its specified output value(s), and each independently reads back its

observed value of the output.

This module is part of the Compact 200 Series I/O subsystem described in Compact

200 Series I/O Subsystem Overview (PSS 41H-2COV).

Aredundant contact output block in the control software validates each output in

conjunction with information to/from the module.

Features

• Eight discrete outputs/Eight discrete voltage monitor inputs

• Eight discrete inputs read back the voltage across the relay contacts. Sets the

channel BAD if the state of the contact disagrees with the state of the

corresponding output channel

• Monitors each FBMoutput and sets the output channel BAD if the output is in the

wrong state

• Single or redundant module

• Termination Assemblies (TAs) for locally or remotely connecting field wiring to the

Compact FBM240

• Supports discrete relay outputs capable of switching:

◦ 10Aat80to120VAC,or

◦ 5Aat80to125VDC,or

◦ 5Aat15to30VDC,or

◦ 5Aat80to120VAC

• Supports channel-isolated discrete I/O:

◦ 15-60VDC@2A,fusedoutputs

◦ 15-60VDCinputs

NOTE: Support for this termination assembly and the new Fail-Safe

configuration options described in Fail-Safe, page 6 require version 1.40N or

later firmware.

• Redundantoperation failure detection

◦ Outputcontact monitor readback and high coverage of internal FBM detected

failures allows redundant partner to automatically continue to drive discrete

outputs and to monitor inputs

• Internal per channel output demand state failure detection

◦ OutputChannel is marked BAD in both Single and Redundant Operation if the

demand state read-back indicates a state of miss-compare

Internal Readback of Output

The Compact FBM240has8internal readback channels, one per each output

channel, used to verify that the output has changed to the requested state. These

channels read the voltage across the relay contacts on the relay termination

assemblies. The states of these channels are displayed on LEDs on the front panel of

the Compact FBM240. When external power is applied to the relay contact of each

channel, the LED for that channel is ON when the relay contact is CLOSED, and OFF

when the relay contact is OPEN. If the state of the contact disagrees with the state of

the corresponding output channel, the channel is marked BAD.

The FBMalso monitors each of its eight outputs and sets the corresponding output

channel BAD if the output is in the wrong state.

If the channel or input power is marked BAD, the CP presents that information to the

Foxboro DCS for display as a System Management alarm and as a control block

alarm

Redundant Outputs

Aredundant contact output function block, COUTR, is used for each redundant pair of

outputs. The COUTR block handles output writes and initialization logic for the

redundant channels. On each write of the COUTR block, identical output writes are

sent to both modules, fully exercising the Fieldbus and the logic circuitry of each

module. You can select a sustained output that follows the block input or a pulsed

output with a selectable pulse width.

Whenafailure is detected in one of the modules, its output is marked BAD and the

corresponding channel in the good module automatically continues to drive the

discrete outputs.

Each output channel drives an externally powered load. Power for each Compact

FBM240module is diode OR’d together in the redundant adapter to help assure

redundant power. The microprocessor of each module executes the digital output

application program, plus diagnostic routines that validate the health of the FBM.

Fail-Safe

Configurable options for output safety include:

• Digital Output Fail-Safe Fallback Data- specifies the channel fallback value (0 or

1) for each of the eight digital outputs

• Maskoption- determines which of the eight digital outputs hold its current value

and which outputs assume the fallback values

• Fieldbus Fail-Safe Delay Time- length of time the FBM waits for a communication

from the CP before entering a communications fail

Redundant Modules

For redundant modules, the Fail-Safe Fallback Data and mask options are

configurable. An additional option is provided so that the module data will fall back to

zero (0) when the module is put off-line for maintenance functions so that it will not

interfere with the remaining module which is still on-line.

The Compact FBM240requires version 1.40N or later firmware to support this feature.

Single Modules

For single modules, the Fail-Safe Fallback Data and Mask options are configurable.

Compact Design

The Compact FBM240’s design is narrower than the standard 200 Series FBMs. It

has a rugged Acrylonitrile Butadiene Styrene (ABS) exterior for physical protection of

the circuits. Enclosures specially designed for mounting the FBMs provide various

levels of environmental protection, up to G3 harsh environments, per ISA Standard

  • ADLINK PCI-7841/cPCI-7841 Dual-port Isolated CAN Interface Cards
  • ADLINK PCI-7841/cPCI-7841 Dual-port Isolated CAN Interface Cards
  • ADLINK Peripherals & Accessories cPCI-3548
  • ADLINK Peripherals & Accessories cPCI-8301
  • ADLINK Peripherals & Accessories cPCI-3W10
  • ADLINK Analog Output cPCI-6208/6216 Series
  • ADLINK Multi-Function DAQ cPCI-9116
  • ADLINK 3U CompactPCI Blades CT-3620
  • ADLINK 3U CompactPCI Blades cPCI-3620
  • ADLINK 3U CompactPCI Blades cPCI-3620
  • ADLINK 3U CompactPCI Blades cPCI-3630
  • ADLINK 3U CompactPCI Blades cPCI-3640 Series
  • 3U CompactPCI Blades cPCI-3520 Series
  • ADLINK IMB-M42H ATX Motherboards
  • Adlink PCIe-GIE74 /PCIe-GIE74V Frame Grabbers / Video Capture Cards
  • ADLINK USB-1605 Removable screw terminal blocks or high-density D-Sub
  • Adlink ETX-NR667-L7400/LXE ETX Module
  • ADLINK NuPRO-842LV/P industrial control motherboard
  • ADLINK cPCI-8994 Serial Communication
  • ADLINK / PCI-7432 Digital I/O
  • ADLINK IEC-915GV Compact industrial-grade fanless embedded system
  • ADLINK ADLINK, PLX / PCI-7296 Digital I/O
  • ADLINK HPCI-14S12U 0040 Backplane Selection Guide
  • ADLINK MXE-5500 /MXE-5501/M16G (G) Fanless Embedded Computer
  • Adlink Multi-Function DAQ PCI-9112
  • ADLINK NuPRO-852LV Control Board
  • ADLINK CompactPCI cPCI-7432R Digital I/O Module
  • ADLINK NUPRO-E320LV PICMG Single Board Computers
  • ADLINK PICMG Single Board Computers NuPRO-E72
  • ADLINK PICMG Single Board Computers NuPRO-865
  • Vibro-Meter Rack VM600SYSMK2-ABE04x 6U 19-inch rack Mk2 system
  • Vibro-Meter Relay expansion RLC16 Mk2 SIL2 (single card) 600-044L
  • Vibro-Meter Relay expansion RLC16 Mk2 SIL2 600-04
  • Vibro-Meter Relay expansion RLC16 Mk2 600-045L
  • Vibro-Meter Relay expansion RLC16 Mk2 600-045
  • Vibro-Meter I/O interface card  IOCN Mk2    600-051
  • Vibro-Meter CPU controller   CPUM Mk2  600-050
  • Vibro-Meter I/O interface card    IOC10 Mk2 (rear card)    600-046
  • Vibro-Meter Temperature / Analog Acquisition  AMC10 Mk2  600-042
  • Vibro-Meter I/O interface card IOC4 Mk2 600-043
  • Vibro-Meter Protective measuring card MPC4 Mk2 SIL2 601-041-A10
  • Vibro-Meter Protective measuring card MPC4 Mk2 601-041-A0
  • Vibro-Meter PSU-VM600 VM600 Rack Power Module
  • Vibro-Meter ABE056 - 1U ultra-thin single-rack
  • Vibro-Meter ABE046 - 6U 19-inch rack
  • Vibro-Meter ABE045 - 6U 19-inch rack
  • Vibro-Meter ABE044 - 6U 19-inch rack (with expansion slots)
  • Vibro-Meter ABE042 6U 19-inch rack (4 slots)
  • Vibro-Meter I/O interface card XIO16T
  • Vibro-Meter XMC16 16-channel combustion monitoring card
  • Vibro-Meter XMV16 - 16-channel vibration condition monitoring card
  • Vibro-Meter RLC16 Relay Card
  • Vibro-Meter IRC4 Intelligent Relay Card
  • Vibro-Meter IOCR2 input/output rear interface card
  • Vibro-Meter CPUR2 Central Processing and Controller Card
  • Vibro-Meter I/O interface card  -  IOCR
  • VIBRO-METER CPU controller CPUR
  • VIBRO-METER IOCN 200-585-000-322 I/O interface card
  • VIBRO-METER IOCN 200-585-000-321 I/O Interface Card
  • VIBRO-METER 200-595-074-323 VM600 system CPU management card, non-redundant
  • VIBRO-METER CPUM 200-595-074-322 CPU Controller
  • VIBRO-METER CPU controller CPUM 200-595-070-321
  • Vibro-Meter IOC8T VM600 Mk1 I/O Interface Card
  • Vibro-Meter AMC8 Analog Monitoring Card
  • VIBRO-METER IOC4G2 I/O interface card
  • VIBRO-METER MPC4G2 Protective measuring card
  • VIBRO-METER IOC4T 200-560-101-017 VM600 Mk1 Isolated I/O Interface Card, equipped with MPC4
  • VIBRO-METER IOC4T 200-560-101-015 VM600 Mk1 interface card
  • VIBRO-METER IOC4T 200-560-000-114 I/O interface card
  • VIBRO-METER IOC4T 200-560-000-113 I/O interface card
  • VIBRO-METER IOC4T 200-560-000-111 Sensor wiring
  • VIBRO-METER MPC4 200-510-072-212 Protection Measurement Card
  • VIBRO-METER MPC4 200-510-071-114 Protective Measurement Card
  • VIBRO-METER 200-510-071-111 4-channel vibration protection + 2-speed channels
  • VIBRO-METER 200-510-070-111 4-channel vibration protection + 2-speed channels
  • ADLINK PICMG Single Board Computers NuPRO-E315
  • ADLINK High Speed Link (HSL) PCI-7853
  • ADLINK Digital I/O PCIe-7432
  • ADLINK Mini-ITX Embedded Boards AmITX-AL-I
  • ADLINK 6U CompactPCI 2.0 Blades cPCI-6860A
  • ADLINK NuPRO-900A PICMG Single Board Computers
  • ADLINK Analog Output PCI-6308 Series
  • ADLINK USB DAQ USB-2405
  • ADLINK CRR-LX800-E-500 Compact Industrial Computer Module (COM)
  • ADLINK 15-slot 6U PXI/CompactPCI Chassis with AC PXIS-3320
  • ADLINK NUPRO-842 PICMG Single Board Computers
  • ADLINK PCI-8124-C Advanced 4-CH Encoder Card
  • ADLINK PCI-8102 Centralized Motion Controllers PCI-8102
  • ADLINK PCIe-7200 High-Speed DIO
  • SEL SEL-7201 Feeder Protection Panel
  • SEL SEL-7206 Distribution Bus Differential Protection Panel
  • SEL SEL-4388 Mirrored Bits Tester
  • SEL SEL-T4287 Traveling-Wave Test System
  • SEL SEL-4000 Relay Test System
  • SEL SEL-9510 Control Switch Module
  • SEL SEL-9502 Contact Arc Suppressor
  • SEL SEL-9501 Contact Arc Suppressor
  • SEL SEL-2652 Trip Coil Monitor
  • SEL SEL-2894 Interface Converter
  • SEL SEL-2890 Ethernet Transceiver
  • SEL SEL-2886 EIA-232 to EIA-485 Interface Converter
  • SEL SEL-9220 Fiber-Optic Adapter for SEL-300 Series Relays
  • SEL SEL-2824 Multimode Fiber-Optic EIA-485 Transceivers
  • SEL SEL-2820 Multimode Fiber-Optic EIA-485 Transceivers
  • SEL SEL-2815 Fiber-Optic Transceiver/Modem
  • SEL SEL-2814 Fiber-Optic Transceivers With Hardware Flow Control
  • SEL SEL-2812 Fiber-Optic Transceivers With IRIG-B
  • SEL SEL-2810 Fiber-Optic Transceivers With IRIG-B
  • SEL SEL-2831 Single-Mode Fiber-Optic Transceiver/Modem
  • SEL SEL-2830 Single-Mode Fiber-Optic Transceiver/Modem
  • SEL SEL-2829 Single-Mode Fiber-Optic Transceiver/Modem
  • SEL SEL-C805 200 µm Multimode Fiber-Optic Cable
  • SEL SEL-C804 Multimode Arc-Flash Detection Fiber-Optic Cables
  • SEL SEL-9331 Power Supply
  • SEL SEL-9322 15 VDC Power Supply
  • SEL SEL-9321 Low-Voltage DC Power Supply
  • SEL SEL-LPS Linear Power Supply
  • SEL SEL-RPM Redundant Power Module
  • SEL SEL-7250 Digital Direct-Replacement Assemblies
  • SEL SEL-2533 Annunciator
  • SEL SEL-2523 Annunciator Panel
  • SEL SEL-2522 Alarm Panel
  • SEL SEL-2516 Rack-Mount Remote I/O Module
  • SEL SEL-2515 Remote I/O Module
  • SEL SEL-2507 High-Speed Remote I/O Module
  • SEL SEL-2506 Rack-Mount Remote I/O Module
  • SEL SEL-2505 Remote I/O Module
  • SEL SEL-3401 Digital Clock