FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module

From:Foxboro | Author:kongjiang | Time :2025-12-09 | 755 Browse: | 🔊 Click to read aloud ❚❚ ▶ | Share:

FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module

FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module

Overview

Single input/single output control schemes with high availability requirements can take

advantage of the FBM208 arranged as a redundant pair. A readback feature is

provided that detects failures of the output channel. In a repair situation, when a single

module is replaced, the inputs and outputs are maintained by the redundant module.

HART

signals are electrically compatible with the 4-20 mA signals, permitting the

plant to upgrade field devices without the need to change the control system. The

FBM208b provides the same functionality and is used to upgrade from the older

FBM05.

Aredundant pair of the modules combine to provide redundancy at the Fieldbus

Module (FBM) level, with field I/O wired to one common termination assembly (TA)

(see Figure 1. page 4). Each module independently attempts to hold the output(s) at

its specified output value(s), and each independently reports its observed value of the

inputs.

Aredundant analog iput and redundant analog output block in the Foxboro

DCS

Control Software validates each input and output in conjunction with information to/

from the module.

The FBM208is electrically compatible with standard HARTsignals.

• Four0to20mADCanaloginputchannels

• Four0to20mADCanalogoutputchannels with readback

• ComparesFBM’soutput value with the current readback value. If the readback

value differs from the desired output by more than ± 2%, the FBM marks its

output channel BAD.

• Monitors FBM’s internal channel current loop power and marks the channel BAD

if power is less than 16 VDC

• Marking achannel Bad causes the corresponding channel in the redundant

module to continue to drive the outputs

• Redundantmodules increase reliability

• Termination Assemblies (TAs) for locally or remotely connecting field wiring to the

FBM208

The FBMcomparesits output value with the current readback value. If the readback

value differs from the desired output by more than ±2%, the FBM marks its output

channel BAD. In addition, if the output value is greater than the desired output by

more than +2%, the power to that channel is shut off to help prevent the bad channel

from interfering with the control of that channel by the redundant partner FBM. The

power to a detected failed channel remains off until the FBM is replaced or rebooted

by the user.

Whenthe FBM’soutput channel is marked BAD, the CP presents that information to

the Foxboro DCS for display as a System Management alarm message and as a

control block alarm.

Redundant Analog Inputs

Each input channel accepts an analog sensor input such as a 4 to 20 mA transmitter

or a self-powered 4 to 20 mA source.

Transmitter power from each module is diode OR’d together in the redundant adapter

to help assure redundant power.

Aredundant analog input function block, AINR, is used for each redundant pair of

inputs. The AINR block handles input reads and initialization logic for the redundant

channels. On each execution cycle of the AINR block, identical reads are sent to both

modules, fully exercising the fieldbus and the logic circuitry of each module.

Input channel options include a configurable choice of integration time on a per

module basis. Input channel availability is enhanced by redundantly powering the

input current loop from per channel power supplies in each module of the pair.

Redundant Analog Outputs

Each output channel drives an external load and produces a 0 to 20 mA output.

Aredundant analog output block, AOUTR, is used for each redundant pair of outputs.

The AOUTRblock handles output writes and initialization logic for the redundant

channels. On each execution cycle of the AOUTR block, identical output writes are

sent to both modules, fully exercising the fieldbus and the logic circuitry of each

module. When a failure is detected in one of the modules, its output is driven to 0 mA

and the corresponding channel in the good module automatically continues supplying

the proper current to the output current loop.

Configurable options in the modules for output failsafe and fallback options are always

set to their default values (0 mA). This removes one of the pair of redundant output

channels from service for detectable problems such as a module not properly

receiving output writes or not passing diagnostic tests on FBM microprocessor writes

to output registers. Using the default failsafe/fallback options of 0 mA output also

minimizes the possibility of a “fail high” result.

High Accuracy

High Reliability

For high accuracy, the module incorporates sigma-delta converters for each channel.

This provides new analog input readings every 25 ms and a configurable integration

period to remove any process noise and power line frequencies. Each time period, the

FBMconverts each analog input to a digital value, averages these values over the

time period and provides the averaged value to the controller.

The redundancy of the module pair, coupled with the high coverage of detected faults,

provides a very high subsystem availability time.

The microprocessor of each module executes the analog I/O application program,

plus diagnostic routines that validate the health of the FBM.

  • Beckhoff CX5620-0225    CPU module
  • Beckhoff CX5620-0220    CPU module
  • Beckhoff CX5620-0215    CPU module, Beckhoff RT Linux®
  • Beckhoff CX5620-0210 CPU module, Beckhoff RT Linux®
  • Beckhoff CX5620-0195    CPU module
  • Beckhoff CX5620-0190    CPU module
  • Beckhoff CX5620-0185    CPU module
  • Beckhoff CX5620-0175    CPU module
  • Beckhoff CX5620-0170  CPU module
  • Beckhoff CX5620-0163    CPU module
  • Beckhoff CX5620-0162 CPU module
  • Beckhoff CX5620-0161 CPU module
  • Beckhoff CX5620-0160 CPU module
  • Beckhoff CX5620-0100 CPU module
  • Beckhoff CX5120-0195    CPU module
  • Beckhoff CX5120-0190 CPU module
  • Beckhoff CX5120-0185 CPU module
  • Beckhoff CX5120-0175 CPU module
  • Beckhoff CX5120-0170    CPU module
  • Beckhoff CX5120-0163    CPU module
  • Beckhoff CX5120-0162    CPU module,
  • Beckhoff CX5120-0161    CPU module
  • Beckhoff CX5120-0160 CPU module,
  • Beckhoff CX5120-0150 CPU module
  • Beckhoff CX5120-0143 CPU module
  • Beckhoff CX5120-0142 CPU module
  • Beckhoff CX5120-0141 CPU module, Microsoft Windows 10 IoT Enterprise 2016 LTSB
  • Beckhoff CX5120-0140 CPU module
  • Beckhoff CX5120-0130 CPU module
  • Beckhoff CX5120-0123 CPU module
  • Beckhoff CX5120-0122 CPU module
  • Beckhoff CX5120-0120 CPU module
  • Beckhoff CX5120-0113 CPU module
  • Beckhoff CX5120-0112 CPU module
  • Beckhoff CX5120-0111 CPU module
  • Beckhoff CX5120-0110 CPU module
  • Beckhoff CX5120-0100 CPU module, no operating system
  • Beckhoff C6017-0040 | Fanless ultra-compact Industrial PC
  • Beckhoff C6017 | Fanless ultra-compact Industrial PC
  • Beckhoff C6015-0030  | Fanless ultra-compact Industrial PC
  • Beckhoff C6015-0040 | Fanless ultra-compact Industrial PC
  • Beckhoff C6015 | Fanless ultra-compact Industrial PC
  • Beckhoff CX2500-M510 | Fieldbus master module
  • Beckhoff CX2500-M310 | Fieldbus master module
  • Beckhoff CX2500-B510 | Fieldbus slave module
  • Beckhoff CX2500-B310 | Fieldbus slave module PROFIBUS for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-0070 | USB 3.0 module for CX20xx, CX52xx, CX53x0. CX56x0
  • Beckhoff CX2500-0062 | 2.5 Gbit Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-1061 | Power over Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-1060 | Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-0031 | Serial Interface RS485/RS422
  • Beckhoff CX2500-0030 | Serial Interface RS232 for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX5230-0195 CPU module
  • Beckhoff CX5230-0190    CPU module
  • Beckhoff CX5230-0175    CPU module,
  • Beckhoff CX5230-0170  CPU module
  • Beckhoff CX5230-0100    CPU module, no operating system, no TwinCAT
  • Beckhoff CU8130-0240 | UPS modul, battery-backed
  • Beckhoff CU8130-0120 | UPS module, battery-backed
  • Beckhoff CU8110-0120 | UPS module, capacitive
  • Beckhoff CU8110-0060 | UPS module, capacitive
  • Beckhoff CX5130-0195    CPU module
  • Beckhoff CX5130-0190    CPU module
  • Beckhoff CX5130-0185 CPU module
  • Beckhoff CX5130-0170    CPU module
  • Beckhoff  CX5130-0163 CPU module, Microsoft Windows 10 IoT Enterprise 2019 LTSC, 32 bit
  • Beckhoff  CX5130-0162    CPU module
  • Beckhoff CX5130-0161  CPU module
  • Beckhoff CX5130-0160    CPU module
  • Beckhoff CX5130-0155  CPU module
  • Beckhoff CX5130-0150    CPU module
  • Beckhoff CX5130-0143 CPU module
  • Beckhoff CX5130-0142 CPU module
  • Beckhoff CX5130-0140    CPU module
  • Beckhoff CX5130-0135 CPU module
  • Beckhoff CX5130-0130 CPU module
  • Beckhoff CX5130-0125    CPU module
  • Beckhoff CX5130-0123    CPU module
  • Beckhoff CX5130-0122    CPU module
  • Beckhoff CX5130-0121 CPU module
  • Beckhoff CX5130-0115    CPU module,
  • Beckhoff CX5130-0113    CPU module
  • Beckhoff CX5130-0112   CPU module
  • Beckhoff CX5130-0111   CPU module
  • Beckhoff CX5130-0110 CPU module, Microsoft Windows Embedded Compact 7. no TwinCAT
  • Beckhoff CX5130-0100  CPU module, no operating system, no TwinCAT
  • DEIF FAS-113DG Synchronisation & circuit breaker closing
  • DEIF FAS-115DG Synchronisation & circuit breaker closing
  • DEIF HAS-111DG Synchronisation & circuit breaker closing
  • DEIF LSU-122DG Load sharing, paralleling & operation
  • DEIF LSU-114DG Load sharing, paralleling & operation
  • DEIF LSU-113DG Load sharing, paralleling & operation
  • DEIF LSU-112DG Load sharing, paralleling & operation
  • DEIF RMF-112D Frequency relay
  • DEIF RMC-142D Current relay
  • DEIF RMC-132D Current relay
  • DEIF RMC-131D Current relay
  • DEIF RMC-122D Current relay
  • DEIF RMC-121D Current relay
  • DEIF RMC-111D Current relay
  • DEIF MVR-V211 Busbar Protection
  • DEIF MVR-T257 Transformer Differential Protection
  • DEIF MVR-T256 Transformer Differential Protection
  • DEIF MVR-T216 Transformer Differential Protection
  • DEIF MVR-T215 Transformer Protection
  • DEIF MVR-M257 Motor Differential Protection
  • DEIF MVR-M255 Motor Protection
  • DEIF MVR-M215 Motor Protection
  • DEIF MVR-M210 Motor Protection
  • DEIF MVR-G257 Generator Differential Protection
  • DEIF MVR-G215 Generator Protection
  • DEIF MVR-F255 Directional Feeder Protection
  • DEIF MVR-F215 Directional Feeder Protection
  • DEIF MVR-F210 Feeder Protection
  • DEIF MVR-F205 Directional Feeder Protection
  • DEIF MVR-F201 Basic Feeder Protection
  • DEIF MVR-200 series Medium Voltage Relay
  • DEIF MDR-2 Multi-differential relay
  • DEIF LMR-122D Loss of mains relay
  • DEIF LMR-111D Loss of mains relay
  • DEIF APU-4 Advanced G59 and G99 protection unit
  • DEIF iE 650 PLC - The most robust programmable automation controller available
  • DEIF iE 350 PLC - Programmable Automation PLC Controller
  • DEIF iE 250 PLC Versatile and modular intelligent energy PLC controller
  • DEIF PPM-3 EDG Protection and Power Management
  • DEIF AGC 3X 4198000234E AUTOMATIC GENSET CONTROLLER
  • SAUTER ASF123 Damper actuator with spring return
  • SAUTER ASF122 Damper actuator with spring return