KONG -Y
NameDescriptionContent
Location:

ABB PCS6000 PRODUCT FAMLIY

From: | Author:kongjiang | Time :2025-07-24 | 1476 Browse: | 🔊 Click to read aloud ❚❚ ▶ | Share:

Introduction, terms, trademarks and related documents

Equipment covered by this manual

This manual covers a standard converter and provides generic information on the converter. The manual does not claim to cover all variations and details of the converter, nor to consider all eventualities that may arise during installation, commissioning, operation and maintenance of the converter. If the converter is adapted to specific customer needs or applications, and handling, installation and operation of the converter are affected by these modifications, information on these modifications is provided in the appropriate documentation (eg, layout drawings, wiring diagrams, technical data, engineering notes). If information is required beyond the instructions in this manual, refer the matter to ABB.

Overview

This manual covers the standard PCS6000 equipment and provides generic information. The manual does not claim to cover all variations and details of the equipment, nor to consider all eventualities that may arise during installation, commissioning, operation and maintenance of the equipment. If the equipment is adapted to specific customer needs or applications, and if handling, installation, and operation of the equipment are affected by these modifications, specific information is provided in the appropriate documentation (eg, layout drawings, wiring diagrams, technical data, and engineering notes) in the appendices. Each person responsible for the transportation, installation, operation, commissioning, preventive maintenance or troubleshooting must have read and fully understood the corresponding chapters in this PCS6000 user's manual and in particular chapter 2, Important safety information, page 19. These responsible persons must ensure that all involved personnel follows the relevant instructions from this manual.

Important safety information

Safety standards

The following industry standards are observed:

– ANSIZ535.6

– ISO3864-2

– ISO7010

– EN50110

Safety messages

The following safety messages are provided to help prevent personal injury and damage to the equipment. The indicated hazard level is based on the ANSI Z535.6 standard. This is the safety alert symbol. It is used to alert you to potential physical injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.

Product safety labels

Safety labels are affixed to the converter components to alert personnel of potential hazards when working on the equipment. For more information, see the label placement document for the converter. The instructions on the safety labels must always be followed and the labels must be kept in a perfectly legible condition.

Figure 2–1 Product warning label examples (label placement depends on the converter)

Additional safety labels, including the following, might also be provided:

General safety instructions

1) Minimize hazards 2) Before energizing the converter: 

 • Remove all foreign objects from the converter 

 • Fasten all internal and external covers securely 

 • Close, lock, and/or bolt all doors 

 • Move the release dial of the door safety switches into the locked position 3) Before working on the converter: 

 • Turn off, lock out, and tag out the main and auxiliary power supplies to the converter 

 • De-energize the converter 

 • Ensure that the safety ground connections are in place 

 • Ensure that the appropriate personal protective equipment (PPE) is available and used when required 

 • Inform the involved personnel about the potential safety hazards 4) While working on the converter: 

 • Wear hearing protection when a converter is running. 

 • Do not step on the roof. 

 • Do not install foreign objects on the roof. 5) Before working on a water cooling unit (WCU): In addition to the safety instructions for working on a converter, always read the WCU safety data sheet for relevant safety information, eg, the type of ion exchange resin and glycol. 6) Before working simultaneously on the converter and on other converter system equipment: 

 • Observe the relevant safety codes and standards 

 • Turn off all energy sources for the equipment 

 • Ensure that all lockout and tagout devices are in place 

 • Install barriers around and use appropriate covers on the equipment that is still energized 

 • Inform the involved personnel about the potential safety hazards 7) In case of fire in the converter room: 

 • Observe the established rules and regulations for fire safety 

 • Only allow firefighters with the appropriate PPE to enter the converter room

The 7 steps that save lives

ABB’s 7 steps that save lives concept is a series of actions that must take place prior to commencing work on or near electrical installations. PRODUCT PCS6000 1) Prepare for the work: do an on-site risk assessment or job hazard analysis that considers the limits of approach for shock and arc-flash. 

 • Be in possession of a clear work order to execute the work. 

  • Eaton MPS8604WEAXX2C Magnum low voltage power circuit breaker
  • Eaton MPS8404WEAXXSW Magnum low voltage power circuit breaker
  • Eaton MPN6504LEAXX3A
  • Eaton MPSC323VEAXX2A Magnum low voltage power circuit breaker
  • Eaton SPS6304WEAXX2F Power Defense SB
  • Eaton MPN6504LEAXX2H Magnum low voltage power circuit breaker
  • Eaton MPSC504HEAXX2H Magnum low voltage power circuit breake
  • Eaton SPN85N3LEAXX2F Power Defense SB
  • Eaton SPN6403CEAXX2F Power Defense SB
  • Eaton MPSC5N4MEAXX3A Power Defense SB
  • Eaton SPSC124WEAXX2A Power Defense SB
  • Eaton SPS85A4WEAXX2H Power Defense SB
  • Eaton SPSC5N4MEAXX2A Power Defense SB
  • Eaton MPN8403VEAXX2H Magnum low voltage power circuit breaker
  • NZMB2-4-A200 MCCB NZM, NZM2 TM and Elec
  • Eaton NZMN1-A63 Series NZM complete molded case circuit breaker
  • Eaton NZMB1-S26-CNA Series NZM complete molded case circuit breaker
  • Eaton NZMH2-A25-NA Series NZM complete molded case circuit breaker
  • NZMH2-A200-BT-NA Eaton Series NZM complete molded case circuit breaker
  • NZMN4-VEF1200-NA Eaton Series NZM complete molded case circuit breaker
  • NZMH2-AF250-NA MCCB NZM, NZM2 TM and Elec
  • NZMB1-AF60-NA Eaton Series NZM complete molded case circuit breaker
  • NZMN1-A50 Eaton Series NZM complete molded case circuit breaker
  • NZMH2-A80-NA Eaton Series NZM complete molded case circuit breaker
  • Eaton Cutler-Hammer HFD3030 6639C86G87 3 Pole 30A 600V Circuit Breaker
  • Moeller XV-230-57CNN-1-13-1 HMI PLC Panel Touchscreen 5.7"
  • EATON CEAG CU CG-S , 40071360300 Control Unit
  • EATON SDN90186 MOTOR CONTROL CENTER
  • EATON HMCP150U4 CIRCUIT BREAKER
  • Eaton 7801C57 Digitrip Optimizer Hand Held Programmer
  • Eaton HMCP400R5 Circuit Breaker
  • EATON MP-3000 SAFETY RELAY 66D2032GX1
  • EATON PGGLOBL1701DPRO 1785T Touch Panel
  • Eaton, Moeller, Easy MFD-CP8-NT
  • Eaton WL-35717F Vacuum Interrupter
  • EATON VICKERS EEA-PAM-535-A-32 AMPLIFIER CARD
  • EATON FP5000-00 / FP5200-00 66D2041G11 FEEDER PROTECTION RELAY
  • Eaton IQ-504 120VAC Modular Overload Relay
  • Beckhoff CX5620-0225    CPU module
  • Beckhoff CX5620-0220    CPU module
  • Beckhoff CX5620-0215    CPU module, Beckhoff RT Linux®
  • Beckhoff CX5620-0210 CPU module, Beckhoff RT Linux®
  • Beckhoff CX5620-0195    CPU module
  • Beckhoff CX5620-0190    CPU module
  • Beckhoff CX5620-0185    CPU module
  • Beckhoff CX5620-0175    CPU module
  • Beckhoff CX5620-0170  CPU module
  • Beckhoff CX5620-0163    CPU module
  • Beckhoff CX5620-0162 CPU module
  • Beckhoff CX5620-0161 CPU module
  • Beckhoff CX5620-0160 CPU module
  • Beckhoff CX5620-0100 CPU module
  • Beckhoff CX5120-0195    CPU module
  • Beckhoff CX5120-0190 CPU module
  • Beckhoff CX5120-0185 CPU module
  • Beckhoff CX5120-0175 CPU module
  • Beckhoff CX5120-0170    CPU module
  • Beckhoff CX5120-0163    CPU module
  • Beckhoff CX5120-0162    CPU module,
  • Beckhoff CX5120-0161    CPU module
  • Beckhoff CX5120-0160 CPU module,
  • Beckhoff CX5120-0150 CPU module
  • Beckhoff CX5120-0143 CPU module
  • Beckhoff CX5120-0142 CPU module
  • Beckhoff CX5120-0141 CPU module, Microsoft Windows 10 IoT Enterprise 2016 LTSB
  • Beckhoff CX5120-0140 CPU module
  • Beckhoff CX5120-0130 CPU module
  • Beckhoff CX5120-0123 CPU module
  • Beckhoff CX5120-0122 CPU module
  • Beckhoff CX5120-0120 CPU module
  • Beckhoff CX5120-0113 CPU module
  • Beckhoff CX5120-0112 CPU module
  • Beckhoff CX5120-0111 CPU module
  • Beckhoff CX5120-0110 CPU module
  • Beckhoff CX5120-0100 CPU module, no operating system
  • Beckhoff C6017-0040 | Fanless ultra-compact Industrial PC
  • Beckhoff C6017 | Fanless ultra-compact Industrial PC
  • Beckhoff C6015-0030  | Fanless ultra-compact Industrial PC
  • Beckhoff C6015-0040 | Fanless ultra-compact Industrial PC
  • Beckhoff C6015 | Fanless ultra-compact Industrial PC
  • Beckhoff CX2500-M510 | Fieldbus master module
  • Beckhoff CX2500-M310 | Fieldbus master module
  • Beckhoff CX2500-B510 | Fieldbus slave module
  • Beckhoff CX2500-B310 | Fieldbus slave module PROFIBUS for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-0070 | USB 3.0 module for CX20xx, CX52xx, CX53x0. CX56x0
  • Beckhoff CX2500-0062 | 2.5 Gbit Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-1061 | Power over Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-1060 | Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-0031 | Serial Interface RS485/RS422
  • Beckhoff CX2500-0030 | Serial Interface RS232 for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX5230-0195 CPU module
  • Beckhoff CX5230-0190    CPU module
  • Beckhoff CX5230-0175    CPU module,
  • Beckhoff CX5230-0170  CPU module
  • Beckhoff CX5230-0100    CPU module, no operating system, no TwinCAT
  • Beckhoff CU8130-0240 | UPS modul, battery-backed
  • Beckhoff CU8130-0120 | UPS module, battery-backed
  • Beckhoff CU8110-0120 | UPS module, capacitive
  • Beckhoff CU8110-0060 | UPS module, capacitive
  • Beckhoff CX5130-0195    CPU module
  • Beckhoff CX5130-0190    CPU module
  • Beckhoff CX5130-0185 CPU module
  • Beckhoff CX5130-0170    CPU module
  • Beckhoff  CX5130-0163 CPU module, Microsoft Windows 10 IoT Enterprise 2019 LTSC, 32 bit
  • Beckhoff  CX5130-0162    CPU module
  • Beckhoff CX5130-0161  CPU module
  • Beckhoff CX5130-0160    CPU module
  • Beckhoff CX5130-0155  CPU module
  • Beckhoff CX5130-0150    CPU module
  • Beckhoff CX5130-0143 CPU module
  • Beckhoff CX5130-0142 CPU module
  • Beckhoff CX5130-0140    CPU module
  • Beckhoff CX5130-0135 CPU module
  • Beckhoff CX5130-0130 CPU module
  • Beckhoff CX5130-0125    CPU module
  • Beckhoff CX5130-0123    CPU module
  • Beckhoff CX5130-0122    CPU module
  • Beckhoff CX5130-0121 CPU module
  • Beckhoff CX5130-0115    CPU module,
  • Beckhoff CX5130-0113    CPU module
  • Beckhoff CX5130-0112   CPU module
  • Beckhoff CX5130-0111   CPU module
  • Beckhoff CX5130-0110 CPU module, Microsoft Windows Embedded Compact 7. no TwinCAT
  • Beckhoff CX5130-0100  CPU module, no operating system, no TwinCAT
  • DEIF FAS-113DG Synchronisation & circuit breaker closing
  • DEIF FAS-115DG Synchronisation & circuit breaker closing
  • DEIF HAS-111DG Synchronisation & circuit breaker closing
  • DEIF LSU-122DG Load sharing, paralleling & operation