KONG -Y
NameDescriptionContent
Location:

Kongsberg d0000930 presafe-atex-report signed

From:Kongsberg | Author:kongjiang | Time :2026-01-07 | 656 Browse: | 🔊 Click to read aloud ❚❚ ▶ | Share:

General product information:

Abbreviations used are: DUT: Devices Under Test (built-in modules).           KM: Kongsberg Maritime AS

Built-in modules included in this investigation are:

Modules Art. No. Description Specs

RAIV400 600370 Remote Analogue Input Voltage 24Vdc, max 0.9A power consumption. Heat

dissipation10W

RDIO420S 316564 Remote Digital Input Output 24Vdc, max 0.9A power consumption. Heat

dissipation10W

RMP420 306712 Remote Multipurpose I/O 24Vdc, 10W, Loop current max 1A per channel

RMP420S 319824 RMP420S (S version) 24Vdc, 10W, Loop current max 1A per channel

RMP422 388820 Remote Multipurpose I/O 24Vdc, 10W, Loop current max 1A per channel

RMP422S 363350 RMP422S (S version) 24Vdc, 10W, Loop current max 1A per channel

RCU502 330924 Remote Control Unit 24Vdc, 20W power consumption, 20W heat

dissipation

RSER200-4 603444 Serial Line Interface 24Vdc, 160mA

RHUB200-5 603442 RBUS Hub 24Vdc, 100mA

BUS-TERM 310955 BUS-Termination 24Vdc

RMC-TERM 346007 Remote Media Converter Termination 24Vdc

RMC-ST 321520 Remote Media Converter-ST 24Vdc, 80mA

EFI-16 321492 Earth Fault Indicator 24Vdc, max 100mA

Refer to Hardware Module Description (HMD) for comprehensive details of technical specifications

Intended use.

The built-in modules are intended for different application as parts of communication system/station. The cabinets

required for these built-in modules must have minimum IP54 rating. ‘X’-marking associated to special condition of

use is used. However safety concern was taken into account in considerations for relevant tests (e.g. thermal

endurance test).

Since external cabinet and the number of used modules at the end application are unknown, safety concern relied

on special condition of use. See ‘Condition of Use’. The internal temperatures are in any cases monitored by the

control system, e.g. internal air temperature.

Investigation of modules RMP420S & RMP422S (S-versions) is considered to be representative for modules

RMP420 & RMP422 since electronics is the same, only software may be different. The later designed module

RMP422S has multipurpose application which may/can cover the usage of several other listed modules as well.

Reset-switch and other addressable switch on a few modules may also be used only during testing/service/repair

or initializing start-up procedure of DUT where the service personnel must follow the normal safety procedures

before any service/repair work. See Special condition of use. Those switches are not used in normal operation

mode. Warning and safety precaution are provided for these switches and their application. See Copy of marking

plate.

Design.

All modules have internal transient protection except for module. RSER200-4 module is however interconnected

between other modules with internal transient protection. All modules have power dissipation approximately to or

less than 20W, therefore these built-in modules are considered as non-sparking low power equipment complying

with clause 13 of IEC60079-15: 2010. Requirements of creepage & air clearance distances are exempted. The

operating input voltage for all modules is 24Vdc, all secondary analogue and digital voltages are derived from

24Vdc input for functional purposes. Assessments are based therefore on 24Vdc as the only operating voltage.

0V reference of 24Vdc input is connected to module’s metal frame. DUT may be earthed in the end installation

and may be evaluated in the end use. Power supply with galvanic separation must be used in the end application.

Connection facilities and suitable terminals are provided. The cable lug connection may be used only during

testing or initializing start-up procedure of DUT. Cable lug is not used otherwise in normal operation mode. All

wiring is to be internal in the end installation.

General product information:

The module EFI-16 Earth Fault Indicator is used to monitor the input and output current and which indicates an

earth fault. Relay K1 on EFI-16 module is investigated for ‘nC’ requirements of IEC60079-15: 2010. Module EFI

16 is therefore evaluated for nA & nC type of protection.

Opto-couplers are used as functional separation for I/O signal of communication system. Opto-couplers have no

safety function and are treated as any other ICs due to the fact that investigation is based on requirements of

non-sparking low power equipment.

Test configuration / considerations

Built-in modules have different rated input voltage range. The output current on I/O channels are consequently

controlled & distributed so that the thermal & power aspects do not exceed the defined limits.  All channels are

short circuit protected. For high current outputs the cut-off point is by default limited to 1.08 Amp for each

channel, regardless of the supplied voltage (18 – 32VDC). Output is shutdown at input voltage less than the max

rated voltage due to this reason. Thermal condition and current are monitored and are controlled by the ma

Measurement Section, including Additional Narrative Remarks (as deemed applicable)

Clause 5.3 Maximum surface temperatures

Clause 26.5 Thermal tests. Temperatures measurements documented in Appendix B.1 of the associated

  • Eaton SPN6084LEAXX2F Power Defense SB
  • Eaton MPNC4N3LEAXXSW Magnum low voltage power circuit breaker
  • EatonSP N8403YEAXX2H Power Defense SB
  • Eaton MPS8604WEAXX2C Magnum low voltage power circuit breaker
  • Eaton MPS8404WEAXXSW Magnum low voltage power circuit breaker
  • Eaton MPN6504LEAXX3A
  • Eaton MPSC323VEAXX2A Magnum low voltage power circuit breaker
  • Eaton SPS6304WEAXX2F Power Defense SB
  • Eaton MPN6504LEAXX2H Magnum low voltage power circuit breaker
  • Eaton MPSC504HEAXX2H Magnum low voltage power circuit breake
  • Eaton SPN85N3LEAXX2F Power Defense SB
  • Eaton SPN6403CEAXX2F Power Defense SB
  • Eaton MPSC5N4MEAXX3A Power Defense SB
  • Eaton SPSC124WEAXX2A Power Defense SB
  • Eaton SPS85A4WEAXX2H Power Defense SB
  • Eaton SPSC5N4MEAXX2A Power Defense SB
  • Eaton MPN8403VEAXX2H Magnum low voltage power circuit breaker
  • NZMB2-4-A200 MCCB NZM, NZM2 TM and Elec
  • Eaton NZMN1-A63 Series NZM complete molded case circuit breaker
  • Eaton NZMB1-S26-CNA Series NZM complete molded case circuit breaker
  • Eaton NZMH2-A25-NA Series NZM complete molded case circuit breaker
  • NZMH2-A200-BT-NA Eaton Series NZM complete molded case circuit breaker
  • NZMN4-VEF1200-NA Eaton Series NZM complete molded case circuit breaker
  • NZMH2-AF250-NA MCCB NZM, NZM2 TM and Elec
  • NZMB1-AF60-NA Eaton Series NZM complete molded case circuit breaker
  • NZMN1-A50 Eaton Series NZM complete molded case circuit breaker
  • NZMH2-A80-NA Eaton Series NZM complete molded case circuit breaker
  • Eaton Cutler-Hammer HFD3030 6639C86G87 3 Pole 30A 600V Circuit Breaker
  • Moeller XV-230-57CNN-1-13-1 HMI PLC Panel Touchscreen 5.7"
  • EATON CEAG CU CG-S , 40071360300 Control Unit
  • EATON SDN90186 MOTOR CONTROL CENTER
  • EATON HMCP150U4 CIRCUIT BREAKER
  • Eaton 7801C57 Digitrip Optimizer Hand Held Programmer
  • Eaton HMCP400R5 Circuit Breaker
  • EATON MP-3000 SAFETY RELAY 66D2032GX1
  • EATON PGGLOBL1701DPRO 1785T Touch Panel
  • Eaton, Moeller, Easy MFD-CP8-NT
  • Eaton WL-35717F Vacuum Interrupter
  • EATON VICKERS EEA-PAM-535-A-32 AMPLIFIER CARD
  • EATON FP5000-00 / FP5200-00 66D2041G11 FEEDER PROTECTION RELAY
  • Eaton IQ-504 120VAC Modular Overload Relay
  • Beckhoff CX5620-0225    CPU module
  • Beckhoff CX5620-0220    CPU module
  • Beckhoff CX5620-0215    CPU module, Beckhoff RT Linux®
  • Beckhoff CX5620-0210 CPU module, Beckhoff RT Linux®
  • Beckhoff CX5620-0195    CPU module
  • Beckhoff CX5620-0190    CPU module
  • Beckhoff CX5620-0185    CPU module
  • Beckhoff CX5620-0175    CPU module
  • Beckhoff CX5620-0170  CPU module
  • Beckhoff CX5620-0163    CPU module
  • Beckhoff CX5620-0162 CPU module
  • Beckhoff CX5620-0161 CPU module
  • Beckhoff CX5620-0160 CPU module
  • Beckhoff CX5620-0100 CPU module
  • Beckhoff CX5120-0195    CPU module
  • Beckhoff CX5120-0190 CPU module
  • Beckhoff CX5120-0185 CPU module
  • Beckhoff CX5120-0175 CPU module
  • Beckhoff CX5120-0170    CPU module
  • Beckhoff CX5120-0163    CPU module
  • Beckhoff CX5120-0162    CPU module,
  • Beckhoff CX5120-0161    CPU module
  • Beckhoff CX5120-0160 CPU module,
  • Beckhoff CX5120-0150 CPU module
  • Beckhoff CX5120-0143 CPU module
  • Beckhoff CX5120-0142 CPU module
  • Beckhoff CX5120-0141 CPU module, Microsoft Windows 10 IoT Enterprise 2016 LTSB
  • Beckhoff CX5120-0140 CPU module
  • Beckhoff CX5120-0130 CPU module
  • Beckhoff CX5120-0123 CPU module
  • Beckhoff CX5120-0122 CPU module
  • Beckhoff CX5120-0120 CPU module
  • Beckhoff CX5120-0113 CPU module
  • Beckhoff CX5120-0112 CPU module
  • Beckhoff CX5120-0111 CPU module
  • Beckhoff CX5120-0110 CPU module
  • Beckhoff CX5120-0100 CPU module, no operating system
  • Beckhoff C6017-0040 | Fanless ultra-compact Industrial PC
  • Beckhoff C6017 | Fanless ultra-compact Industrial PC
  • Beckhoff C6015-0030  | Fanless ultra-compact Industrial PC
  • Beckhoff C6015-0040 | Fanless ultra-compact Industrial PC
  • Beckhoff C6015 | Fanless ultra-compact Industrial PC
  • Beckhoff CX2500-M510 | Fieldbus master module
  • Beckhoff CX2500-M310 | Fieldbus master module
  • Beckhoff CX2500-B510 | Fieldbus slave module
  • Beckhoff CX2500-B310 | Fieldbus slave module PROFIBUS for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-0070 | USB 3.0 module for CX20xx, CX52xx, CX53x0. CX56x0
  • Beckhoff CX2500-0062 | 2.5 Gbit Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-1061 | Power over Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-1060 | Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-0031 | Serial Interface RS485/RS422
  • Beckhoff CX2500-0030 | Serial Interface RS232 for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX5230-0195 CPU module
  • Beckhoff CX5230-0190    CPU module
  • Beckhoff CX5230-0175    CPU module,
  • Beckhoff CX5230-0170  CPU module
  • Beckhoff CX5230-0100    CPU module, no operating system, no TwinCAT
  • Beckhoff CU8130-0240 | UPS modul, battery-backed
  • Beckhoff CU8130-0120 | UPS module, battery-backed
  • Beckhoff CU8110-0120 | UPS module, capacitive
  • Beckhoff CU8110-0060 | UPS module, capacitive
  • Beckhoff CX5130-0195    CPU module
  • Beckhoff CX5130-0190    CPU module
  • Beckhoff CX5130-0185 CPU module
  • Beckhoff CX5130-0170    CPU module
  • Beckhoff  CX5130-0163 CPU module, Microsoft Windows 10 IoT Enterprise 2019 LTSC, 32 bit
  • Beckhoff  CX5130-0162    CPU module
  • Beckhoff CX5130-0161  CPU module
  • Beckhoff CX5130-0160    CPU module
  • Beckhoff CX5130-0155  CPU module
  • Beckhoff CX5130-0150    CPU module
  • Beckhoff CX5130-0143 CPU module
  • Beckhoff CX5130-0142 CPU module
  • Beckhoff CX5130-0140    CPU module
  • Beckhoff CX5130-0135 CPU module
  • Beckhoff CX5130-0130 CPU module
  • Beckhoff CX5130-0125    CPU module
  • Beckhoff CX5130-0123    CPU module
  • Beckhoff CX5130-0122    CPU module
  • Beckhoff CX5130-0121 CPU module
  • Beckhoff CX5130-0115    CPU module,
  • Beckhoff CX5130-0113    CPU module
  • Beckhoff CX5130-0112   CPU module
  • Beckhoff CX5130-0111   CPU module
  • Beckhoff CX5130-0110 CPU module, Microsoft Windows Embedded Compact 7. no TwinCAT
  • Beckhoff CX5130-0100  CPU module, no operating system, no TwinCAT
  • DEIF FAS-113DG Synchronisation & circuit breaker closing