KONG -Y
NameDescriptionContent
Location:

Hirschmann Media converter MM20-M4M4T1T1EAHH

From: | Author:kongjiang | Time :2025-04-14 | 881 Browse: | 🔊 Click to read aloud ❚❚ | Share:

Technical parameters and safety
Safety instructions

Shielded ground The shielded ground wire of the twisted pairs lines is connected to the front panel as a conductor. 

 Beware of possible short circuits when connecting a cable section with conductive shield braiding. 

 Housing Only technicians authorized by the manufacturer are permitted to open the housing. WARNING ELECTRIC SHOCK Never insert any pointed objects (small screwdrivers, wires, etc.) into the product! Never insert sharp objects (small screwdrivers, wires, etc.) into the connection terminals for the supply voltage or the signal contact, and do not touch the terminals! Failure to follow these instructions can result in death, serious injury, or equipment damage. CAUTION EQUIPMENT OVERHEATING When installing the device, make sure any ventilation slots remain free. Maintain a clearance of at least 10 cm (3.94 in). Failure to follow these instructions can result in injury or equipment damage. 10 PowerMICE Release 01 04/2014 The lower panel of the device is grounded by means of the DIN rail and optionally by means of the separate ground screw. 

 The switch basic module forms an inseparable unity. By removing the display and connecting parts, you risk the damage of the switch basic module. 

 Make sure that the electrical installation meets local or nationally applicable safety regulations. 

 The ventilation slots must not be covered to promote free air circulation. 

 The clearance between the ventilation slots of the housing and other objects must be at least 10 cm (3.94 in). 

 The device has to be mounted in an upright position (see fig. 13). 

 If installed in a living area or office environment, the device must be operated exclusively in switch cabinets with fire protection characteristics in accordance with EN 60950-1. 

 Environment The device may only be operated at the specified surrounding air temperature (temperature of the surrounding air at a distance of up to 5 cm (1.97 in) from the device) and relative air humidity specified in the technical data. 

 Install the device in a location where the climatic threshold values specified in the technical data will be observed. 

 Use the device only in an environment within the pollution degree specified in the technical data. 

 Qualification requirements for personnel Qualified personnel as understood in this manual and the warning signs, are persons who are familiar with the setup, assembly, startup, and operation of this product and are appropriately qualified for their job. This includes, for example, those persons who have been:  trained or directed or authorized to switch on and off, to ground and to label power circuits and devices or systems in accordance with current safety engineering standards; 

 trained or directed in the care and use of appropriate safety equipment in accordance with the current standards of safety engineering; 

 trained in providing first aid. 

 General safety instructions Electricity is used to operate this equipment. Comply with every detail of the safety requirements specified in the operating instructions regarding the voltages to apply. See “Supply voltage” on page 6.

Non-observance of these safety instructions can therefore cause material damage and/or injuries. 

 Only appropriately qualified personnel should work on this device or in its vicinity. Qualified personnel must be thoroughly familiar with the warnings and maintenance procedures in accordance with this operating manual. 

 The proper and safe operation of this device depends on proper handling during transport, proper storage and assembly, and conscientious operation and maintenance procedures. 

 Never start operating the device with damaged components. 

 Only use the devices in accordance with this manual. In particular, observe the warnings and safety-related information. 

 Any work that may be required on the electrical installation may only be carried out by personnel trained for this purpose. Note: LED or LASER components in compliance with IEC 60825-1 (2007): CLASS 1 LASER PRODUCT CLASS 1 LED PRODUCT Note: Follow the safety instructions for the media modules. You will find these instructions in the “Description and Operating Instructions” document supplied with the media module. 

 National and international safety regulations 

 Make sure that the electrical installation meets local or nationally applicable safety regulations. 

 CE marking The labeled devices comply with the regulations contained in the following European directive(s): 2011/65/EU (RoHS) Directive of the European Parliament and of the Council on the restriction of the use of certain hazardous substances in electrical and electronic equipment. 2004/108/EC (EMC) Directive of the European Parliament and the council for standardizing the regulations of member states with regard to electromagnetic compatibility. In accordance with the above-named EU directive(s), the EU conformity declaration will be at the disposal of the relevant authorities at the following address:

  • AMAT 0100-00046 AC Current Sense PWB
  • AMAT A0414720 Precision Advanced System Controller
  • AMAT 0010-00017 Precision Semiconductor Process Interface
  • AMAT 01-82889-00 High-Performance Semiconductor Component
  • ABB Sample Gas Cooler SCC-C 23070-0-10232110
  • IBA ibaRackline-PCHD Efficient process analysis with ibaHD-Server
  • IBA ibaRackline-PC CAM Frame-accurate video information with ibaCapture
  • IBA ibaRackline-PC Highly available and reliable
  • IBA Optical Signal Multiplier ibaBM-FOX-i-3o-D
  • IBA Optical Data Distribution System ibaBM-DIS-i-8o
  • IBA Optical Data Concentrator ibaBM-COL-8i-o
  • IBA ibaNet750-BM-D Acquisition via FO
  • IBA ibaW-750 Acquisition via Ethernet
  • IBA ibaPADU-8AI-I Compact Measurement Modules
  • IBA ibaPADU-D-8AI-I Compact Measurement Modules
  • IBA ibaPADU-D-8AI-U Compact Measurement Modules
  • IBA ibaPADU-4-AI-U Compact Measurement Modules
  • IBA ibaPADU-C-8AI Self-Supplied Data Logger
  • IBA ibaBM-ENetIP Bus monitor for EtherNet/IP
  • IBA ibaBM-eCAT Bus monitor for EtherCAT
  • IBA ibaBM-DP Bus monitor for PROFIBUS
  • IBA ibaBM-PN Bus monitor for PROFINET IO
  • IBA ibaMS3xAI-1A Precision AC Current Measurement Module
  • IBA ibaDAQ Intelligent Central Unit
  • IBA ibaPQU-S Power Quality Monitoring System
  • IBA ibaCMU-S Condition Monitoring Unit (CMU)
  • IBA ibaPADU-S-IT-2x16 Modular data acquisition and control system
  • IBA ibaPADU-S-CM Modular data acquisition system
  • IBA ibaM-4AI-IEPE Input module
  • IBA ibaM-4AI-UI Input module
  • IBA ibaM-4AI-150V-AC Input module
  • IBA ibaM-4AI-600V-AC Input module
  • IBA ibaLink-SM-256V High-Density PLC Data Interface
  • IBA ibaLink-SM-64V High-Performance S5/S7 Interface
  • IBA ibaLink-SM-128V-i-2o Synchronous Fiber Optic (ibaNet)
  • IBA ibaLink-SM-128V communication module
  • IBA ibaM-4AI-5A-150A-AC Input module
  • IBA ibaM-FO-2IO Interface module
  • IBA ibaM-COM Communication module
  • IBA ibaM-DAQ Intelligent Processor Module
  • B&R ECNT43-0 MULTI power supply module
  • B&R ECEP128-0 MULTI application memory
  • B&R ECCP60-01 MULTI CPU type B 42 KByte SRAM
  • B&R DI426 digital input module
  • B&R 2DS100.60-1 electronic drum sequencer Absolut encoder
  • B&R 2CP100.60-1 CPU MODULE
  • B&R 2BM100.9 High-performance I/O module
  • AMAT 0190-14928 SCR Power Controller (PVD Reverse Zone)
  • AMAT 0500-01065 300mm Loadlock Interface Interlock Board
  • AMAT 2000-21123 Advanced Vacuum Seal Assembly
  • AMAT 0660-00090 High-Performance Industrial Power Filter
  • AMAT 0240-34077 Centura Endpoint Controller Kit
  • AMAT 0195-10215 High-Precision Pedestal Assembly
  • AMAT 0190-76050 VGA Video Controller VME Module
  • AMAT 0190-75084 High-Performance Communication & Logic Controller
  • AMAT 0190-60287 Precision VME/cPCI Interface Control Module
  • AMAT 0190-53752 DI Water I/O Controller PCB
  • AMAT 0190-37993 DeviceNet Scanner Pro (3U CompactPCI)
  • AMAT 0190-37833 MKS CDN500R-5 EPI 300mm Interface Module
  • AMAT 0190-37771 MKS CDN500R Interlock Control Module
  • AMAT 0190-37616 High-Precision Analog Input/Output Interface
  • AMAT 0190-36787B ISAC CP I/O Block 2 (Top) - Revision B
  • AMAT 0190-36787 ISAC CP I/O Block 2 (Top)
  • AMAT 0190-36511 DIP294 DeviceNet I/O Control Block
  • AMAT 0190-35764 & 0190-35765: Precision Control Interface Duo
  • AMAT 0190-35763 High-Performance Integrated Power Module
  • Applied Materials (AMAT) 0190-34512: 4-Channel DeviceNet Scanner Interface
  • Applied Materials (AMAT) 0190-34282 High-Stability Process Control Module
  • Applied Materials (AMAT) 0190-27707 High-Precision DeviceNet I/O Controller
  • Applied Materials (AMAT) 0190-27072 High-Performance Semiconductor Interface
  • AMAT 0190-24007 CPCI-3720CF Single Board Computer
  • AMAT 0190-23905 Spellman ESC High Voltage Power Supply
  • AMAT 0190-22967 High-Density Analog I/O Control Board
  • AMAT 0190-22543 High-Precision Analog Input/Output Module
  • AMAT 0190-17894 Interlock Module Conductor HART
  • AMAT 0190-17081 2U CompactPCI System Host Processor
  • AMAT 0190-16926 and 0190-16928 Based on Compact PCI
  • AMAT 0190-15915 Intelligent I/O Control Module
  • AMAT 0190-15840 4-Port UPA DeviceNet Interface Module
  • AMAT 0190-15384 Advanced Digital Signal Interface Module
  • AMAT 0190-15384 Advanced Digital Signal Interface Module
  • AMAT 0190-14027 Wafer Flat Finder PCB
  • AMAT 0190-12695 SBS CL7 3U CompactPCI Single Board Computer
  • AMAT 0190-11817 CP3-SER16-TTL 16-Port Serial Interface Card
  • AMAT 0190-11524 CDN500-25 Interlock Module
  • AMAT 0190-07450 CompactPCI 48-Channel Digital I/O Interface Board
  • AMAT 0190-05990-001 Maglev Rotation System Controller (300mm)
  • AMAT 0190-05647 LK3710 Serial Module Transition Card
  • AMAT 0190-04457 High-Performance Integrated Circuit Control Module
  • Applied Materials (AMAT) 0190-04098 | 5.X Factory Interface I/O Distribution Board
  • Applied Materials (AMAT) 0190-03705 | MF Producer SE/E Interlock Module
  • Applied Materials (AMAT) 0190-02748 | Flex Scanner Transition Module
  • Applied Materials (AMAT) 0190-01227 | Intelligent Motor Control OMS Board
  • Applied Materials (AMAT) 0190-00318 | VME 486 Video Controller
  • Applied Materials (AMAT) 0130-14007 | Advanced RF Signal Assembly
  • Applied Materials (AMAT) 0130-14005 | RF Cable/Interface Assembly
  • Applied Materials (AMAT) 0110-77040 | Head Pneumatic Controller
  • Applied Materials (AMAT) 0110-00077 | Precision Control Module
  • AMAT 0101-57015 high-performance Next-Generation Deflection Amplifier Board
  • AMAT 0100-77040 critical Head Pneumatic Controller Board
  • AMAT 0100-76291 Data Buffer / Memory Expansion Interface
  • AMAT 0100-76290 Advanced I/O Interface Board
  • AMAT 0100-76269 Control Board / Interface Module
  • AMAT 0100-71462-01 high-performance Process Controller PCB
  • AMAT 0100-71171 Chamber Interlock Control PCB
  • AMAT 0100-71154 Semiconductor Circuit Board / Electronic Group Card
  • AMAT 0100-70034 PCB Assembly (PCBA) for Endpoint VGA I/O Interconnect.
  • AMAT 0100-38032 ESC (Electrostatic Chuck) Controller PCB
  • AMAT 0100-36035 DPS Source Match / Seriplex I/O Distribution PCB
  • AMAT 0100-35231 Seriplex I/O Distribution Module
  • AMAT 0100-35217 TC Amp Interlock PCB Module
  • AMAT 0100-35065 High-Precision Serial Isolator PCB
  • AMAT 0100-35054 Advanced Chamber Interface Module
  • AMAT 0100-20453 DeviceNet Digital I/O Interface Board
  • AMAT 0100-20100 High-Performance Semiconductor Component
  • AMAT 0100-20068 Precision CCD Image Control Board
  • AMAT 0100-20064 Advanced Semiconductor Control Module
  • AMAT 0100-20018 Advanced Communication Interface Module
  • Applied Materials (AMAT) 0100-20016 High-Performance Interface and Control Module
  • Applied Materials (AMAT) 0100-20003 Digital I/O (DI/DO) Interface Board
  • Applied Materials (AMAT) 0100-20001 System Electronics Interface (SEI) / PCB Assembly
  • Applied Materials (AMAT) 0100-11030 Chamber Hardware / Gas Distribution Component
  • Applied Materials (AMAT) 0100-11022 Semiconductor Board Card
  • Applied Materials (AMAT) 0100-11018 Advanced Interface Control Module
  • Applied Materials (AMAT) 0100-11001 Precision Analog Output Board
  • ​Applied Materials (AMAT) 0100-11000 High-Precision Analog Input Board
  • Applied Materials (AMAT) 0100-09237 Advanced Signal Interface Module
  • Applied Materials (AMAT) 0100-09204 Advanced Digital Interface Control Board