KONG -Y
NameDescriptionContent
Location:

Hirschmann Media converter MM20-M4M4T1T1EAHH

From: | Author:kongjiang | Time :2025-04-14 | 80 Browse: | Share:

Technical parameters and safety
Safety instructions

Shielded ground The shielded ground wire of the twisted pairs lines is connected to the front panel as a conductor. 

 Beware of possible short circuits when connecting a cable section with conductive shield braiding. 

 Housing Only technicians authorized by the manufacturer are permitted to open the housing. WARNING ELECTRIC SHOCK Never insert any pointed objects (small screwdrivers, wires, etc.) into the product! Never insert sharp objects (small screwdrivers, wires, etc.) into the connection terminals for the supply voltage or the signal contact, and do not touch the terminals! Failure to follow these instructions can result in death, serious injury, or equipment damage. CAUTION EQUIPMENT OVERHEATING When installing the device, make sure any ventilation slots remain free. Maintain a clearance of at least 10 cm (3.94 in). Failure to follow these instructions can result in injury or equipment damage. 10 PowerMICE Release 01 04/2014 The lower panel of the device is grounded by means of the DIN rail and optionally by means of the separate ground screw. 

 The switch basic module forms an inseparable unity. By removing the display and connecting parts, you risk the damage of the switch basic module. 

 Make sure that the electrical installation meets local or nationally applicable safety regulations. 

 The ventilation slots must not be covered to promote free air circulation. 

 The clearance between the ventilation slots of the housing and other objects must be at least 10 cm (3.94 in). 

 The device has to be mounted in an upright position (see fig. 13). 

 If installed in a living area or office environment, the device must be operated exclusively in switch cabinets with fire protection characteristics in accordance with EN 60950-1. 

 Environment The device may only be operated at the specified surrounding air temperature (temperature of the surrounding air at a distance of up to 5 cm (1.97 in) from the device) and relative air humidity specified in the technical data. 

 Install the device in a location where the climatic threshold values specified in the technical data will be observed. 

 Use the device only in an environment within the pollution degree specified in the technical data. 

 Qualification requirements for personnel Qualified personnel as understood in this manual and the warning signs, are persons who are familiar with the setup, assembly, startup, and operation of this product and are appropriately qualified for their job. This includes, for example, those persons who have been:  trained or directed or authorized to switch on and off, to ground and to label power circuits and devices or systems in accordance with current safety engineering standards; 

 trained or directed in the care and use of appropriate safety equipment in accordance with the current standards of safety engineering; 

 trained in providing first aid. 

 General safety instructions Electricity is used to operate this equipment. Comply with every detail of the safety requirements specified in the operating instructions regarding the voltages to apply. See “Supply voltage” on page 6.

Non-observance of these safety instructions can therefore cause material damage and/or injuries. 

 Only appropriately qualified personnel should work on this device or in its vicinity. Qualified personnel must be thoroughly familiar with the warnings and maintenance procedures in accordance with this operating manual. 

 The proper and safe operation of this device depends on proper handling during transport, proper storage and assembly, and conscientious operation and maintenance procedures. 

 Never start operating the device with damaged components. 

 Only use the devices in accordance with this manual. In particular, observe the warnings and safety-related information. 

 Any work that may be required on the electrical installation may only be carried out by personnel trained for this purpose. Note: LED or LASER components in compliance with IEC 60825-1 (2007): CLASS 1 LASER PRODUCT CLASS 1 LED PRODUCT Note: Follow the safety instructions for the media modules. You will find these instructions in the “Description and Operating Instructions” document supplied with the media module. 

 National and international safety regulations 

 Make sure that the electrical installation meets local or nationally applicable safety regulations. 

 CE marking The labeled devices comply with the regulations contained in the following European directive(s): 2011/65/EU (RoHS) Directive of the European Parliament and of the Council on the restriction of the use of certain hazardous substances in electrical and electronic equipment. 2004/108/EC (EMC) Directive of the European Parliament and the council for standardizing the regulations of member states with regard to electromagnetic compatibility. In accordance with the above-named EU directive(s), the EU conformity declaration will be at the disposal of the relevant authorities at the following address:

  • Hirschmann MM20-M4M4T1T1SBH Industrial Ethernet module
  • IC752SPL011 GE control panel
  • GE ALSTOM IR139-1丨063022350丨80801419丨B0037299control card
  • ALSTOM UT150-1 control module
  • ALSTOM AL132丨AL132A Control Card
  • ABB 2CTB802342R0000 surge protector
  • ABB PM118-7BPM1118 MAGNET (NEO) .50LG
  • Tektronix TDP0500 high pressure differential probe
  • Carrier CEPL130403-02-R Microprocessor Board CEBD430403-11-RC 32GB500382EE
  • BENTLY 106M1079-01-Y Power Module Original
  • ABB system module DLM02 original DO610,DO620
  • 1394-SJT22-A servo driver Allen-Bradley servo equipment
  • MOTOROLA SGLF4136FA PLC control system
  • B&R ECPE84-1B Modulus Input Module Quality Service
  • Foxboro FBM213 communication module supply
  • S-093H 3BHB030478R0309 ABB high voltage frequency conversion rack
  • ABB S-123H 3BHB030479R0512 rack
  • ABB 3BHL000406P0103 VFW 30/265Processor unit
  • ALSTOM V4561983-0100 EPIC II ESP controller
  • MOOG G761-3004B5 H38JOGM5VPH Servovalve
  • 3500 BentlyNevada 3500/05-02-01-00-00-00 System rack
  • 3500/05-01-02-00-00-01 Bently Nevada 3500/05 System Rack
  • 3500/05-01-01-00-00-00 BentlyNevada System Rack
  • BentlyNevada 3500/05-02-01-01 System Rack
  • 3500/05-01-01-01-00-00 Bently Nevada 3500/05 System frame
  • BentlyNevada3500/95 System Integrated PC Display
  • 3500/93 Bently Nevada System Display
  • General electric IS215GBIAH1A auxiliary Genius bus interface module
  • MOOG D137-004-006 Servo valve controller
  • MOOG D137-004-005 Industrial controller
  • MOOG D137-004-004 Motion controller
  • D137-004-003 MOOG RDISP 22 operation panel
  • MOOG D138-002-003
  • MC 600 SERIES D138-002-002 MACHINE CONTROLLER MOOG
  • MOOG D138-002-001
  • MOOG B95914-001 Plate and fittings
  • D138-003-010 - Visualization HMI run time license (MACS HMI) for 10 machines
  • MOOG MACS HMI 1 - D138-003-001
  • MOOG D137-002-001 control module
  • MOOG QEBUS-CAN - D137-001-010
  • MOOG QAIO 16/4-V - D137-001-007
  • MOTOROLA MVME7100 - High-Speed Embedded Controller, VME
  • Motorola MVME2432 - VME Embedded Controller
  • Motorola СPU3640FLN3524A - Embedded Processor Module
  • MOTOROLA MVME187-24B01-W36908 - High-Performance
  • Motorola MVME162P-344 - VME Controller, 68040 Processor, Industrial Automation
  • Motorola FLN4234A - Embedded System Controller
  • Motorola MVME2604712 I/O-VME board
  • MOTOROLA MVME-51005E-0163-VME Embedded Controller
  • MOTOROLA MVME162PA-344SE - VME Controller
  • MOTOROLA MVME6100-0161 - High-Performance VME Board
  • MOTOROLA MVME55006E-0161R - Enhanced Performance VME Controller
  • MOTOROLA MVME162-523A - VME Controller
  • Motorola PCB MVME 2434 SBC PMC-HS/GE FANUC PMC661J card
  • Motorola MVME55006E-0163-VME processor board
  • MOTOROLA VME162PA344SE - Enhanced VME Controller
  • MOTOROLA MVME5500 - High-Performance VME Controller
  • MOTOROLA MVME147-023 - Legacy VME Board, Embedded Controller, Industrial Automation
  • MOTOROLA VME162PA-252SE - VME Board, Legacy System Controller, Industrial Automation
  • MOTOROLA MVME6100+5264- VME Board with Memory Expansionerformance Industrial Controller
  • MOTOROLA MVME2305-900 - VME Embedded Controller
  • Motorola MVME3100-1152-Enhanced VME Controller
  • Motorola MVME147-012-Traditional VME Board
  • Motorola MVME147-013-Traditional VME Board
  • MOTOROLA MVME-5101-0131-VME Embedded Controller
  • MOTOROLA MVME5101-0131 - VME Embedded Controller
  • MOTOROLA MVME167P-24SE - VME Controller
  • Motorola MVME7100-0171 - High-Speed Embedded Controller
  • MOTOROLA MVME3100 - High-Performance VME Controller
  • MOTOROLA MVME147-010 - Legacy VME Board,
  • MOTOROLA MVME55006E-0163R - Enhanced Performance VME Controller, Industrial Control Systems
  • MOTOROLA MVME5110-2261 - Enhanced VME Controller
  • MOTOROLA MVME2305-900 - VME Embedded Controller
  • MOTOROLA MVME5100-0163 High-Performance VME Embedded Controller
  • MOTOROLA MVME-147A0-60063-1 - Legacy VME Board, Industrial Automation Applications, Embedded Systems
  • MOTOROLA IPMC761-001 - PMC Carrier Board
  • MOTOROLA MVME6100-163 - Enhanced VME Controller
  • MOTOROLA MVME162-213 - Embedded Controller
  • MOTOROLA MVME162-022A - Embedded VME Board
  • MOTOROLA MVME61006E-0163R+P.N5264 - VME Processor Board
  • MOTOROLA MVME61006E-0161R+P.N5264 - Enhanced VME Processor Board, 1.3 GHz, Memory Card Supported
  • MOTOROLA MVME6100 (01-W3878F14B) - VME Embedded Controller
  • MOTOROLA APPLIED0100-01396 - Applied Computing Board
  • MOTOROLA MVME162PA-344 - VME Controller
  • MOTOROLA MVME2100 - Low-Cost Embedded VME Board
  • Motorola MVME5100-VME embedded controller, high-speed data processing.
  • MOTOROLA MVME162-202 - Embedded Controller, VME
  • MOTOROLA MVME7100-0173-2G - Embedded Controller
  • TRICONEX 2301 - Digital Output Module, High-Speed, Industrial Systems
  • TRICONEX 2351 Analog Input Module, High-Precision
  • TRICONEX 2401-Digital Input Module, Compact
  • TRICONEX 2101 Main Processor Module, Modular, High-Performance
  • TRICONEX 2381 - Digital Input Module, Compact Design, High-Precision
  • TRICONEX 9566-810 Power Supply Module, Modular
  • TRICONEX 8312 - Communication Module
  • TRICONEX FTA-544 Termination Assembly Modular
  • TRICONEX 3604E - TMR Digital Output Module, High-Precision
  • TRICONEX 9566-810F Power Supply Module, Compact
  • TRICONEX 3451 Analog Input Module, Compact
  • TRICONEX 3211S-analog input module
  • TRICONEX DI3301S2 Digital Input Module
  • TRICONEX 3481S2 Analog Output Module, Redundant
  • TRICONEX 3511 Main Processor Module, Modular
  • TRICONEX 3101 Main Processor Module
  • TRICONEX 8111 Communication Module
  • TRICONEX 4210 Analog Input Module
  • TRICONEX 4211 Analog Input Module
  • TRICONEX CIM3211S2 Communication Interface Module
  • TRICONEX MA2211-100S2 Communication Module, Redundant
  • TRICONEX MA2211-100 Communication Module, Compact
  • TRICONEX AO3481 Analog Output Module
  • TRICONEX 3501TN2 - Main Processor Module
  • TRICONEX 3623T Digital Output Module High-Precision
  • TRICONEX 3009 Main Processor Module, High-Speed
  • TRICONEX 3009X - Main Processor Module
  • TRICONEX 8310 Communication Module
  • TRICONEX 3008 - Main Processor Module, Modular, High-Speed
  • TRICONEX 3301-Digital Input Module
  • TRICONEX 3700A-Communication module, high performance
  • TRICONEX 3504E - Main Processor Module
  • TRICONEX 3503E Main Processor Module
  • TRICONEX 3481S Analog Output Module
  • TRICONEX 3351 Analog Input Module
  • TRICONEX 3401 Analog Input Module
  • TRICONEX RXM4201 Communication Module
  • TRICONEX RXM4200-3 - Communication Module
  • TRICONEX 3624 Digital Output Module
  • TRICONEX 3704E - Digital Input Module