Obey these safety precautions before you do work on the system: 

Clearly identify the work location and equipment.

2. Disconnect all possible voltage sources. Make sure that reconnection is not possible. Lock out and tag out.

• Open the main disconnecting device of the AVR.

• Disconnect any external power sources from the control circuits before you do work on the control cables.

• If you have a permanent magnet generator connected to the AVR, disconnect it from the AVR with a safety switch or by other means.

• After you disconnect the AVR, always wait for 5 minutes to let the intermediate circuit capacitors discharge before you continue.

• Do not do work on the AVR when the amber warning LED flashes. 3. Protect any other energized parts in the work location against contact. 4. Take special precautions when you are near bare conductors. 5. Measure that the installation is de-energized.

• Use a multimeter with an impedance of at least 1 Mohm.

• Make sure that the voltage between the AVR input power terminals (PWR L1, PWR L2 and PWR L3) and the grounding terminal (PE) is near 0 V.

• Make sure that the voltage between the AVR output terminals (IE+, IEand ExCap) and the grounding terminal (PE) is close to 0 V. 6. Install temporary grounding as required by the local regulations. 7. Ask for a permit to work from the person in control of the electrical installation work.  Residual danger areas WARNING! Do not do work on the AVR when the amber warning LED flashes. When the AVR operates,

• The voltage in the power section can be up to 300 V AC and the short-circuit current is very high.

• The voltage in the control cabinet is more than 50 V. When the AVR is disconnected from power supplies, the large capacitors in the AVR hold a charge for some time. Wait for at least 5 minutes for the capacitors to discharge before you do work on the AVR. An amber warning LED flashes if the internal voltage is more than 30 V DC. Warning labels are attached to all of the cubicle doors to warn personnel against opening the doors during operation. If the device is built into a larger system, additional warning labels are attached to the inside of the cubicle doors and to the covers of the power converter modules. Consider the residual danger areas when you do work on the excitation system:

• Danger from live equipment inside the excitation system, if the protective covers are removed.

• Hazardous voltages from the rotor field winding and the secondary side of the excitation transformer.

• Danger from charged capacitors if a cabinet door is open immediately after the system stops.

• Danger from main and auxiliary voltages when cubicle doors are open. Introduction This document is a quick installation guide for the UNITROL 1010 and UNITROL 1020 automatic voltage regulator. Make sure that you read and understand this document before you install or use the product. This document is meant only as a brief guide to the product. For detailed information on the product, refer to the User Manual. Device description UNITROL 1010 and UNITROL 1020 are automatic voltage regulators (AVR) for synchronous machines of up to 80 MVA. The AVRs can be used for the excitation of indirectly excited synchronous machines and motors. The AVRs can also operate as a reactive power regulators, power factor regulators or field current regulators. Product package Contents of the product package:

• UNITROL 1000 series AVR

• Special red USB cable that is used to power and to connect with the AVR. Keep this USB cable in a safe place.

• Red jumper blocks (3 pcs.)

• Quick installation guide and test certificate Make sure that all of the listed items are in the product package and that there is no damage to the items. Hardware overview Primary parts of the AVR. Refer to the User Manual for more information.  Warning and status indicators Mechanical installation For detailed information on mechanical installation, refer to the User Manual. Install the AVR in an indoor area that is dry and dust-free, and that does not contain volatile gases, acid fumes or similar hazards. Examine the installation area and refer to technical data to make sure that:

• The maximum ambient temperature is in the permitted range.

• The vibration is limited and within the permitted class.

• The ingress protection and pollution degree are suitable.

• The EMC environment is suitable. Installation requirements:

• Install the AVR vertically to make sure that cooling operates correctly.

• Free space requirements:

• 50 mm above the AVR

• 20 mm below the AVR

• 10 mm on the left and right sides of the AVR

• Make sure that there is sufficient cooling air flow around the AVR.

• Make sure that other devices do not blow hot air on to the AVR.

• The AVR is designed to be installed with suitable hardware to an installation plate.

• Make sure that the frame of the AVR is electrically grounded (PE) to the installation plate with a grounding wire (≥4 mm2) through a mounting hole. Use toothed washers to get a good electrical ground contact. Installation procedure: 1. Refer to Dimensions for the mounting hole dimensions. 2. Make the appropriate holes in the installation plate. 3. Attach the AVR to the installation plate with suitable hardware, for example, M6 screws to a torque of 10 Nm. The mounting holes have a diameter of 6.5 mm. 4. Make sure that there is a good electrical ground connection between the installation plate and the AVR.

  • SEL SEL-9220 Fiber-Optic Adapter for SEL-300 Series Relays
  • SEL SEL-2824 Multimode Fiber-Optic EIA-485 Transceivers
  • SEL SEL-2820 Multimode Fiber-Optic EIA-485 Transceivers
  • SEL SEL-2815 Fiber-Optic Transceiver/Modem
  • SEL SEL-2814 Fiber-Optic Transceivers With Hardware Flow Control
  • SEL SEL-2812 Fiber-Optic Transceivers With IRIG-B
  • SEL SEL-2810 Fiber-Optic Transceivers With IRIG-B
  • SEL SEL-2831 Single-Mode Fiber-Optic Transceiver/Modem
  • SEL SEL-2830 Single-Mode Fiber-Optic Transceiver/Modem
  • SEL SEL-2829 Single-Mode Fiber-Optic Transceiver/Modem
  • SEL SEL-C805 200 µm Multimode Fiber-Optic Cable
  • SEL SEL-C804 Multimode Arc-Flash Detection Fiber-Optic Cables
  • SEL SEL-9331 Power Supply
  • SEL SEL-9322 15 VDC Power Supply
  • SEL SEL-9321 Low-Voltage DC Power Supply
  • SEL SEL-LPS Linear Power Supply
  • SEL SEL-RPM Redundant Power Module
  • SEL SEL-7250 Digital Direct-Replacement Assemblies
  • SEL SEL-2533 Annunciator
  • SEL SEL-2523 Annunciator Panel
  • SEL SEL-2522 Alarm Panel
  • SEL SEL-2516 Rack-Mount Remote I/O Module
  • SEL SEL-2515 Remote I/O Module
  • SEL SEL-2507 High-Speed Remote I/O Module
  • SEL SEL-2506 Rack-Mount Remote I/O Module
  • SEL SEL-2505 Remote I/O Module
  • SEL SEL-3401 Digital Clock
  • SEL SEL-9929 Satellite-Synchronized Clock Display Kit
  • SEL SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver
  • SEL SEL-3400 IRIG-B Distribution Module
  • SEL SEL-2401 Satellite-Synchronized Cloc
  • SEL SEL-2407 Satellite-Synchronized Clock
  • SEL SEL-2488 Satellite-Synchronized Network Clock
  • SEL SEL-5051/5052 Client/Server Network Management System (NMS) Software
  • SEL SEL-5056 Network Management System (NMS)
  • SEL SEL-3031 Serial Radio Transceiverceiver
  • SEL SEL-3061 Cellular Router
  • SEL ICON Integrated Communications Optical Network
  • SEL SEL-3622 Security Gateway
  • SEL SEL-3620 Ethernet Security Gateway
  • SEL SEL-3620 Ethernet Security Gateway
  • SEL SEL-3610 Port Server
  • SEL SEL-2730U Unmanaged 24-Port Ethernet Switch
  • SEL SEL-2725 Five-Port Ethernet Switch
  • SEL SEL-2744 Ethernet Switch
  • SEL SEL-2743 Ethernet Switch
  • SEL SEL-2742 Ethernet Switch
  • SEL SEL-2741 Ethernet Switch
  • SEL SEL-2731 Ethernet Switch
  • SEL SEL-2902 RJ45 to DB-9 Adapter Panel
  • SEL SEL-3390S8 Serial Adapter Card
  • SEL SEL-3390E4 Network Adapter Card
  • SEL SEL-3390T Time and Ethernet Adapter Card
  • SEL SEL-3360 Computing Platform
  • SEL SEL-3355 Computing Platform
  • SEL SEL-5703 Synchrowave Monitoring
  • SEL SEL-5705 Synchrowave Reports
  • SEL Metering Software Solutions
  • SEL SEL-T35 Time-Domain Power Monitor
  • SEL SEL-735 Power Quality and Revenue Meter
  • SEL SEL-TWFL Dual Traveling-Wave Fault Locator and 12-Channel MHz Recorder
  • SEL SEL-5035 acSELerator Diagram Builder Software
  • SEL SEL-5033 acSELerator RTAC Software
  • SEL SEL-2411P Pump Automation Controller
  • SEL SEL-2411 Programmable Automation Controller
  • SEL SEL-3560 Real-Time Automation Controller (RTAC)
  • SEL SEL-3555 Real-Time Automation Controller (RTAC)
  • SEL SEL-3350 Computing Platform
  • SEL SEL-3530-4 Real-Time Automation Controller (RTAC)
  • SEL SEL-3505/3505-3 Real-Time Automation Controller (RTAC)
  • SEL Real-Time Automation Controller (RTAC)
  • SEL SEL-2414 Transformer Automation Controller (TAC)
  • SEL SEL-734B Advanced Monitoring and Control System
  • SEL SEL-734W and LINAM WCS
  • SEL SEL-2431 Voltage Regulator Control
  • SEL SEL-5601-2 Synchrowave Event Software
  • SEL SEL-5032 acSELerator Architect Software
  • SEL SEL-5030 acSELerator QuickSet Software
  • SEL SEL-751A Feeder Protection Relay
  • SEL SEL-751A Feeder Protection Relay
  • SEL SEL-2440 DPAC Discrete Programmable Automation Controller
  • SEL SEL-2240 Axion
  • SEL SEL-401 Protection, Automation, and Control Merging Unit
  • SEL SEL-TMU TiDL Merging Unit
  • SEL SEL-700BT Motor Bus Transfer Relay
  • SEL SEL-849 Motor Management Relay
  • SEL SEL-3790 Low-Voltage Divider Module
  • SEL SEL-710-5 Motor Protection Relay
  • SEL SEL-487V Capacitor Bank Protection, Automation, and Control System
  • SEL SEL-351RS Kestrel Single-Phase Recloser Control
  • SEL SEL-651RA Recloser Control
  • SEL SEL-651R Advanced Recloser Control
  • SEL SEL-551C Overcurrent/Reclosing Relay
  • SEL SEL-351S Protection System
  • SEL SEL-851 Feeder Protection Relay
  • SEL SEL-451 Protection, Automation, and Bay Control System
  • SEL SEL-751 Feeder Protection Relay
  • SEL SEL-311C Transmission Protection System
  • SEL SEL-387L Line Current Differential Relay
  • SEL SEL-311L Line Current Differential Protection and Automation System
  • SEL SEL-787L Line Current Differential Relay
  • SEL SEL-421 Protection, Automation, and Control System
  • SEL SEL-9L Line Relay
  • SEL SEL-411L Advanced Line Differential Protection, Automation, and Control System
  • SEL SEL-587Z High-Impedance Differential Relay
  • SEL SEL-7251 Electromechanical Direct-Replacement Assemblies
  • SEL SEL-787Z High-Impedance Differential Relay and SEL-HZM High-Impedance Module
  • SEL SEL-487B Bus Differential and Breaker Failure Relay
  • SEL SEL-387 Current Differential and Overcurrent Relay
  • SEL SEL-387A Current Differential and Overcurrent Relay
  • SEL SEL-2600 RTD Module
  • SEL SEL-387E Current Differential and Voltage Relay
  • SEL SEL-787-2/-3/-4 Transformer Protection Relay
  • SEL SEL-487E Transformer Protection Relay
  • SEL SEL-2664S Stator Ground Protection Relay
  • SEL SEL-300G Generator Relay
  • SEL SEL-700G Generator Protection Relay
  • SEL SEL-400G Advanced Generator Protection System
  • SEL SEL-T400L Time-Domain Line Protection
  • ADLINK SEL-T401L Ultra-High-Speed Line Relay
  • ADLINK Multi-Function DAQ PCI-9222/9223
  • ADLINK PICMG Single Board Computers NuPRO-A40H
  • ADLINK HSL-4XMO  HSL-4XMO-TB-D103  HSL-4XMO-CD-N-006
  • ADLINK industrial computer motherboard NuPRO-965DV
  • ADLINK PCI-7442 switch card Digital I/O
  • ADLINK PCI-7260 Digital I/O
  • ADLINK PICMG Single Board Computers NuPRO-852
  • ADlink 6U CompactPCI 2.0 Blades cPCI-6840