Блок питания VM600Mk2/VM600 RPS6U
Виброметр питания VM600Mk2 / VM600 RPS6U
KEY FEATURES AND BENEFITS
• From the vibro-meter ® product line
• Power supply for VM600Mk2/ VM600 ABE04x 19 ″ system racks with a height of 6U
• Input: AC-input and DC-input versions
• Outputs: +5 VDC and ±12 VDC • Output over-voltage, short-circuit and overload protection
• Status indicators
• High-power, high-performance, high efficiency
• Minimal derating within the operating
temperature range
APPLICATIONS
• VM600Mk2/ VM600 machinery protection and/ or condition monitoring systems
• One RPS6U rack power supply powers a full rack of modules (cards)
• Two RPS6U rack power supplies enable rack
power supply redundancy
DESCRIPTION
The VM600Mk2/ VM600 RPS6U rack power supplies
are designed for use in the VM600Mk2/ VM600
series of machinery protection systems and
condition and performance monitoring systems,
from Meggitt’s vibro-meter ® product line.
A VM600Mk2/ VM600 RPS6U rack power supply is
installed in the front of a VM600Mk2/ VM600 ABE04x
system rack (19 ″ system racks with a standard
height of 6U) and connects via two high-current
connectors to the VME bus of the rack’s
backplane. The RPS6U power supply provides
+5 VDC and ±12 VDC to the rack itself and all
installed modules (cards) in the rack via the rack’s
backplane.
DESCRIPTION (continued)
Either one or two VM600Mk2/ VM600 RPS6U rack
power supplies can be installed in a VM600Mk2/
VM600 ABE04x system rack. A rack with one
RPS6U power supply (330 W version) supports the
power requirements for a full rack of modules
(cards) in applications with operating
temperatures up to 50 °C (122 °F).
Alternatively, a rack can have two RPS6U power
supplies installed in order to either support rack
power supply redundancy or in order to supply
power to the modules (cards) non-redundantly
over a wider range of environmental conditions.
A VM600Mk2/ VM600 ABE04x system rack with two
RPS6U power supplies installed can operate
redundantly (that is, with rack power supply
redundancy) for a full rack of modules (cards).
This means that if one RPS6U fails, the other will
provide 100 % of the rack’s power requirement so
that the rack will continue to operate, thereby
increasing the availability of the machinery
monitoring system.
Note: This is known as a redundant RPS6U rack
power supply configuration.
A VM600Mk2/ VM600 ABE04x system rack with two
RPS6U power supplies installed can also operate
non-redundantly (that is, without rack power
supply redundancy). Typically, this is only
necessary for a full rack of modules (cards) in
applications with operating temperatures above
50 °C (122 °F), where RPS6U output power derating
is required.
Note: Even though two RPS6U rack power supplies
are installed in the rack, this is not a redundant
RPS6U rack power supply configuration.
The number and type of RPS6U power supplies
installed in a VM600Mk2/ VM600 ABE04x system
rack, together with the number of modules
(cards) installed and the environmental
conditions, helps determine the mode of
operation of the RPS6U power supplies as either
redundant or non-redundant. See also Ordering
information on page 16.
Different versions of the RPS6U rack power supply
enable a VM600Mk2/ VM600 ABE04x system rack
to be powered using external AC and/or DC
mains supplies. All RPS6U power supplies support a
wide input voltage range.
A power supply check relay, available on the
associated rear panel at the rear of a VM600Mk2/
VM600 ABE04x system rack, is used to indicate
that the RPS6U power supplies are operating
normally. Refer to the VM600Mk2/ VM600 ABE04x
system rack data sheet for further information.
In applications where the VM600Mk2/ VM600
ABE04x system rack is powered by an AC mains
supply, a VM600Mk2/ VM600 ASPS auxiliary sensor
power supply can also be included in the rack.
The ASPS provides +24 VDC outputs which can be
used by external sensor/measurement chain
hardware such as front-end sensors, signal
conditioners and galvanic separation units.
For further information, contact your local
Meggitt representative.
Notes
1. In 2016, the RPS6U rack power supply was improved to provide a higher output power of 330 W with higher-performance and higher-efficiency, which required a redesign of the underlying power supply circuitry. Accordingly, the different versions of the RPS6U rack power supply in use are:
• Later versions of the RPS6U (PNR 200-582-x00-02h or later) that define the power as a total maximum output power of 330 W, with nominal output (supply) voltages of +5 VDC up to 50 A, +12 VDC up to 8 A and −12 VDC up to 4 A. Note: The total maximum output power of 330 W is a combination load for all outputs as the +5 VDC and ±12 VDC outputs are usually not simultaneously loaded to the maximum in practice. For example, if the +5 VDC output is at its maximum rated load (5.35 V × 50 A = 267.5 W), then the combined loads on the +12 VDC and −12 VDC outputs must not exceed 62.5 W.
• Earlier versions of the RPS6U (PNR 200-582-x00-01h or earlier) that define the power as a rated power of 300 W, with nominal output (supply) voltages of +5 VDC up to 35 A, +12 VDC up to 6 A and −12 VDC up to 2 A. 2. In 2021, VM600Mk2 (second-generation) machinery monitoring systems were launched with improved rack modules, notably the MPC4Mk2 + IOC4Mk2, RLC16Mk2 and CPUMMk2 + IOCNMk2. VM600Mk2 systems use the same system infrastructure as first-generation VM600 systems, that is, VM600Mk2 is backward compatible with existing VM600 (VM600Mk1) racks and power supplies. However, VM600Mk2 versions of the ABE040 system rack (PNR 200-040-100-016) and RPS6U rack power supplies (PNRs 200-582-200-12h, 200-582-500-12h and 200-582-600-12h) are also available. The VM600Mk2 versions are the same as the latest VM600 versions, except for the specific artwork/branding/finish. More specifically, the front panels of RPS6U rack power supplies are bare aluminium for the VM600Mk2 versions (PNRs 200-582-200-12h, 200-582-500-12h and 200-582-600-12h) and painted for the VM600 versions (PNRs 200-582-200-02h, 200-582-500-02h and 200-582-600-02h).
Environmental Temperature
•Operating
•Storage Humidity (according to IEC 60068-2-30) Vibration (according to IEC 60068-2-6) Shock (according to IEC 60068-2-27) Drop test (according to IEC 60068-2-31) MTBF (according to MIL-HDBK-217F) Conformal coating Indoor use Approvals Conformity Electromagnetic compatibility Electrical safety Overvoltage category Vibration Environmental management Russian federal agency for technical regulation and metrology (Rosstandart) : 0 to 70 °C (32 to 158 °F) : −40 to 85 °C (−40 to 185 °F) : 5 to 90 %, non-condensing : 10 to 55 Hz, 0.35 mm peak below resonance and 2 g peak above, 6 hours /axis : 6 g peak, 11 ms, half-sine pulse, 3 shocks /axis : 30 ° drop angle : > 40 000 hours at 70 °C (158 °F) : Applied to the circuitry of the power supply for additional environmental protection against chemicals, dust, moisture and temperature extremes : Limited to indoor use only : European Union (EU) declaration of conformity (CE marking). EAC marking, Eurasian Customs Union (EACU) certificate/ declaration of conformity. : EN 55022 class “B”. FCC Docket 20780 curve “B”. IEC 61000-4-2: Performance criteria B, 4 kV contact discharge and 8 kV air discharge. IEC 61000-4-3: Performance criteria A, 10V/m. IEC 61000-4-4: Performance criteria A, 2 kV 5/50 ns, 5 kHz, direct IEC 61000-4-6: Performance criteria A, level 3 IEC 61000-4-8: Performance criteria A, 50 Hz / 30 A / m TR CU 020/2011. : IEC / EN / UL / CSA 60950-1, 2nd edition. TR CU 004/2011. : OVC II : IEC 60255-21-1 (Class 2) : RoHS compliant (2011/65 / UE) : Pattern approval certificate OC.C.28.004.A N° 60224
Add: Building F05, High-tech Software Park, Xiamen City, Fujian Province
Tel: 0592-5211302
Mobile: 17750019513 (WhatsApp)
Email: yy4291644@gmail.com
ivy@kongjiangauto.com
Website: https://www.abb-sis.com