KONG -Y
NameDescriptionContent
Location:

Woodward 8290-189-EPG-installation-manual 8290-044

From:Woodward | Author:kongjiang | Time :2026-01-20 | 1212 Browse: | 🔊 Click to read aloud ❚❚ | Share:

8290-189-EPG-installation-manual 8290-044

Installation and Operation Manual

This manual covers Electrically Power Governor (EPG) models 512/524 and

1712/1724. Refer to the appropriate manual or contact Woodward for information

about other versions of the EPG.

Application

The EPG is used to control the speed of diesel, gas, and gasoline engines. It can

also control the speed of gas turbines. Installation of EPG actuators is simple

because they require neither mechanical drive nor hydraulic supply.

The EPG handles prime movers with mechanical loads and generator loads

equally well. Generator sets which will be paralleled, however, require additional

appropriate switch gear, current and potential transformers, and the Woodward

Generator Load Sensor.

An EPG is a three-component system, requiring a magnetic pickup, speed

control, and actuator.

A battery charger must be used to keep the battery charged. Maximum steady

state current consumption is 4 A for the 12-volt models (512/1712), and 3 A for

the 24-volt models (524/1724).

Part Number Selection

Use EPG Model 512/1712 for operation in 12-volt systems. Use Model 524/1724

for operation in 24-volt systems.

Additionally, speed controls are available for four ranges of magnetic pickup

frequencies, for diesel engines and gas turbines, or for gasoline and gas

engines. Actuators have a double-ended output shaft for either clockwise or

counterclockwise rotation to increase fuel.

Speed controls and actuators must be compatible. Use the Part Number

Selection Table below (Table 1-1) to choose compatible EPG speed controls and

actuators.

The optional Start Fuel Limit feature allows setting a maximum actuator position

during start-up. The maximum position remains in effect until the engine reaches

the selected idle or rated speed. The limit may be adjusted out of the way by

turning the adjustment potentiometer fully clockwise.

The Dual Dynamics feature allows tailoring a special set of responses for

unloaded and loaded operating conditions. This type of control is often needed

for gas engines and other systems with non-linear fuel systems. A switch is used

to change between slow and fast dynamics.

Accessories

This manual includes some information about accessories frequently used with

EPGs.

To Parallel Generators

Add the Generator Load Sensor to the EPG in paralleled generator applications.

Woodward makes many accessories for paralleled generator applications.

To Decrease Acceleration and Deceleration

The Ramp Generator or an optional, external capacitor can be used to increase

the time to go from idle to rated speeds and vice versa. The Ramp Generator

provides a linear ramp with times adjustable to 25 seconds in a typical case. It is

useful in smoke-limiting applications. Use the 8271-909 with 24 V batteries and

the 8271-910 for 12 V batteries. The capacitor provides an exponential ramp with

times up to four seconds. Exponential means it changes (speed in this case)

rapidly at first but slows as it approaches its final value. See the typical wiring

diagram for capacitor requirements.

References

These publications can be obtained from your Woodward authorized Distributor

or AISF (Authorized Independent Service Facility). All are also available on the

Woodward website (www.woodward.com).

Catalog

52122

Product

Specification

04106

Manual

25070

82510

Title

Woodward Industrial Control Product Line Catalog

Title

Model 512/1712 & 524/1724 Electrically Powered Governors

Title

Electric Governor Installation Guide

Magnetic Pickups for Electric Governors

direction of rotation for increased fuel by choosing a suitable linkage.

If you are using a Woodward supplied installation kit, follow its instructions and

skip over Linkage Compatibility. Begin again with Installing the Magnetic Pickup.

Linkage Compatibility

Also match linkage linearity to the fuel control. Use a linear linkage as shown in

Figure 2-2 unless the prime mover has a carburetor or other non-linear fuel

control. See Figures 2-3 and 2-4 for a carburetor compensating linkage. Contact

Woodward if a linkage different from those shown is required. Incorrect linearity

matching can cause stable operation at some fuel settings but oscillation at other

fuel settings.

A return spring is included in the actuator. Do not use an additional return spring.

(Low force return springs that may be located in an engine’s valve cover usually

don’t affect EPG performance.)

Make sure that the actuator is capable of moving the fuel control to the maximum

and minimum limits. Let the fuel control limit actuator travel. Set the linkage so

that the actuator is just above minimum when the fuel control is at its minimum

stop and (except for Detroit Diesel engines) so that the actuator is just below

maximum when the fuel control is at its maximum stop. We recommend that

Woodward installation kits be used for Detroit Diesel engines.

Use good rod end connectors. The link connecting the actuator lever to the fuel

control lever must not be so long that it flexes when the prime mover is running.

Installing the Magnetic Pickup

Mount the magnetic pickup through a housing or rigid bracket. Make sure that

the sensed gear is of magnetic material. The gap between the pickup and the

  • SHINKAWA MODEL VM-5Z5,6,7  POWER SUPPLY UNIT
  • SHINKAWA MODEL VM-5Y1,2,3 RELAY MODULE UNIT
  • SHINKAWA MODEL VM-5P3 PHASE MARKER UNIT
  • SHINKAWA MODEL VM-53 DUAL COMMUNICATION UNIT
  • SHINKAWA MODEL VM-52 BOTTOM HOLD MONITOR
  • SHINKAWA MODEL VM-51 ROD DROP MONITOR
  • SHINKAWA MODEL VM-5R TACHOMETER
  • SHINKAWA MODEL VM-5S DUAL TACHOMETER
  • SHINKAWA MODEL VM-5A DUAL VALVE
  • SHINKAWA MODEL VM-5E DUAL CASE
  • SHINKAWA MODEL VM-5L COMPLEMENTARY INPUT
  • SHINKAWA MODEL VM-5N RAMP DIFFERENTIAL
  • SHINKAWA MODEL VM-5D DUAL DIFFERENTIAL
  • SHINKAWA MODEL VM-5T DUAL THRUST MONITOR
  • SHINKAWA MODEL VM-5C ECCENTRICITY MONITOR
  • SHINKAWA MODEL VM-5C ECCENTRICITY MONITOR
  • SHINKAWA MODEL VM-5M DUAL PATH MONITOR
  • SHINKAWA MODEL VM-5B DUAL ACCELERATION MONITOR
  • SHINKAWA MODEL VM-5B DUAL ACCELERATION MONITOR
  • SHINKAWA MODEL VM-5U DUAL SEISMIC MONITOR
  • SHINKAWA MODEL VM-55 VIBRATION MONITOR
  • SHINKAWA VM-742B1-5 VIBRATION MONITORING SYSTEM CARD
  • Shinkawa PSP-17B P-24-64A P-24-64B Circuit Board Module
  • SHINKAWA MGP-67 PCB
  • Shinkawa JBP-278 P-22-48A-1 P-22-48B-1 Circuit Board Module
  • Shinkawa VM-721B 18-CHANNEL RELAY MODULE
  • Shinkawa FRP-337 P-26-54A P-26-54B Circuit Board Module
  • Shinkawa WKN-142K2-2 Vibration Transmitter
  • SHINKAWA VL-202A08L-1012 Rotor Position Monitor Probe Sensor
  • Shinkawa CPP-128 P-26-74A P-26-74B Circuit Board Module
  • Honeywell 51402755-100 PROCESSOR CARD
  • Honeywell 51107595-100 Power
  • HONEYWELL 51304544-100 Control Board
  • HONEYWELL 51109919-100 BOARD
  • HHoneywell 51204160-175 Digital Input Module
  • Honeywell 51304754-150 High Level Analog Input Module
  • HONEYWELL 51304690-100 DIGITAL INPUT CARD
  • Honeywell 51401635-150  COMM CONTROL
  • HONEYWELL 51204174-175 MC-TAOY 52 ANALOG OUTPUT BOARD
  • HONEYWELL  51400596-100
  • HONEYWELL 51401291-100 board card
  • HONEYWELL 51401642-150 I/O LINK MODULE
  • Honeywell LCN‑E Hub Power Supply 38500148‑300
  • Honeywell LCN‑E Hub redundant 38500143‑202 Twisted‑pair LCN
  • Honeywell LCN‑E Hub non‑redundant,38500143‑102
  • Honeywell Enhanced Micro‑TDC‑3000 System Unit MX‑DTAC01K2
  • Honeywell Enhanced Micro‑TDC‑3000 System Unit MX‑DTAB01K2
  • Honeywell Enhanced Micro‑TDC‑3000 System Unit MT11‑520
  • Honeywell STI‑CE Smart Transmitter Interface 51304516‑150
  • Honeywell STI Smart Transmitter Interface 51304516‑100 MC‑PSTX02
  • Honeywell ulse Counter IOP 51304386‑100 MU‑PPIX02
  • Honeywell DO Digital Output IOP‑CE 51304487‑150 CE  version
  • Honeywell DO Digital Output IOP  51304487‑100 MC‑PDOX02
  • Honeywell TDC‑3000 SOE DI IOP,51402625-175 MC‑PDIS12
  • Honeywell TDC‑3000  DI Digital Input IOP‑CE 51304485‑150
  • Honeywell TDC‑3000 DI Digital Input IOP 51304485‑100 MC‑PDIX02
  • Honeywell TDC‑3000 AO Analog Output IOP 51304757‑100 MU‑PAOX02
  • Honeywell TDC‑3000  TC Thermocouple IOP 51304756‑100 MU‑TAMT03
  • Honeywell TDC‑3000   51304755‑100 MU‑TAMR03
  • Honeywell TDC‑3000 LLAI Multiplex AI IOP,51304362‑150
  • Honeywell TDC‑3000  HLAI Analog Input IOP‑CE, 51304363‑150
  • Honeywell TDC‑3000  HLAI Analog Input IOP,51304363‑100.4‑20mA
  • Honeywell TDC‑3000  HPM Power Supply,51401731‑100
  • Honeywell TDC‑3000 Standard 1986.HPM High‑Performance PM CPU,51402362‑100
  • Honeywell TDC‑3000 APM Advanced Process Manager CPU,51304459‑100
  • Honeywell TDC‑3000 Standard 1986.PM Process Manager CPU,51304362‑100
  • Honeywell TDC‑3000 NIM Network Interface Module,51304481‑200
  • Honeywell TDC‑3000 NIM Network Interface Module 51304481‑100
  • Honeywell TDC‑3000 BASIC,LCN Terminator Resistor,30732052‑001.Coaxial
  • Honeywell TDC‑3000 BASIC,Hiway Coupler,30753732‑001
  • Honeywell TDC‑3000 BASIC,LEPIU Low‑Energy PIU,4DP7APCFA309
  • Honeywell TDC‑3000 BASIC,HLPIU High‑Level PIU,4DP7APCFA106
  • Honeywell TDC‑3000 BASIC,Multifunction Controller(TDC‑2000 DHW),4DP7MFA103
  • Honeywell TDC‑3000 BASIC,Extended Controller(TDC‑2000 DHW),4DP7AXA102
  • Honeywell TDC‑3000 BASIC,Basic Controller(TDC‑2000 DHW),4DP7BBA101
  • Honeywell 51305508‑100 TDC‑3000 BASIC,XLCNE2 LCN Extender
  • Honeywell TDC‑3000 BASIC,E‑PLCG PLC Gateway,51400997‑200
  • Honeywell TDC‑3000 BASIC,PLNM Plant Network Module,51401163‑100
  • Honeywell TDC‑3000 BASIC,CG Computer Gateway,80360206‑001
  • Honeywell TDC‑3000 BASIC,HG High‑Speed Gateway,51304526‑100
  • Honeywell TDC‑3000 BASIC,HM History Module,51191596‑200
  • Honeywell TDC‑3000 BASIC,HM History Module,51191596‑100
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑800.K2LCN‑8
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑600.K2LCN‑6
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑400,K2LCN‑4
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑300.K2LCN‑3
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑200,K2LCN‑2
  • Honeywell TDC‑3000 BASIC,US Universal Station CPU,51401288‑200
  • Honeywell TDC‑3000 BASIC,US Universal Station CPU,51401288‑100
  • SHINKAWA VM-21P1 Signal Conditioner 0-50MM 24VDC
  • Shinkawa RiverNew Vibration Transducer VK202 Series
  • Shinkawa Electric VM-3E2 Vibration Monitor Module
  • Shinkawa JBP-47 P-22-48A-1 / P-22-48B-1 Circuit Board Module
  • Shinkawa MODEL VM-5K DUAL VIBRATION MONITOR
  • Shinkawa CMU-15A (CMU15A) Industrial Camera Controller
  • Shinkawa CMU-13A CMU13A Industrial Camera Controller
  • Shinkawa EFU-10 (EFU10) Spark Generator Unit
  • Shinkawa UTC-1000 ZUP-02C Board
  • Shinkawa MDP-89 MDP89 P-24-674A P-24-674B Circuit Board Module
  • Shinkawa CB-1011005001 Signal Cable Assembly
  • SHINKAWA VL-202A08L-1002 Sensor VL-08020L01 Probe Cable F84N1695
  • Shinkawa VK-202A2 Driver & VL-202A08L-1A72 Proximity Sensor Probe
  • SHINKAWA VM-703B VIBRATION MONITORING SYSTEM CARD 2R05-002-P001C
  • Shinkawa BH-150-03 Signal Conditioner / Preamplifier Unit
  • Shinkawa BH-150 Signal Conditioner / Preamplifier Unit
  • Shinkawa Electric VM-3D2 Thrust Monitor Module
  • Shinkawa LCU-37 Monitoring module
  • Shinkawa LCU-44B-06 Local Control Unit Module
  • ABB 3BHE039724R2643 PPD513 high-performance programmable controller module
  • Samsung SSAS21-RTD Resistance Temperature Detector Input Module
  • Samsung SSAS21-AI Analog Input Module
  • Samsung SSAS21-DO Digital Output Module
  • Samsung SSAS21-DI Digital Input Module
  • Samsung SSAS21-CPU Central Processing Unit Module
  • Samsung SMTB-RTD RTD/TC Terminal Board
  • Samsung SMTB-AI Analog Input/Output Terminal Board
  • Samsung SMTB-DO Digital Output Terminal Board
  • Samsung SMTB-DI Digital Input Terminal Board
  • SAMSUNG SMBK-12 IOU Rack Backplane
  • SAMSUNG SMBK-08 IOU Rack Backplane
  • SAMSUNG SMPS-08 Rack Power Module
  • SAMSUNG SMCOM-08 Communication Expansion Card
  • SAMSUNG SMPI-8 Pulse Count Input Module
  • SAMSUNG SMTC-8 Thermocouple Input Module
  • SAMSUNG SMAOC-12 Analog Output Module (12CH)
  • SAMSUNG SMAOC-8 Analog Output Module (8CH)
  • SAMSUNG SMAIC-12 Analog Current Input Module (12CH)
  • SAMSUNG SMRTD-8 RTD Pt100 Temperature Input Module (8CH)