YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)

From:YOKOGAWA | Author:kongjiang | Time :2026-01-26 | 267 Browse: | Share:

Models ANB10S, ANB10D,

ANR10S, ANR10D

Node Units (for FIO)

communicates the analog I/O signals and contact I/O

signals of a field with a Field Control Unit (FCU) via an

ESB bus, as well as a function that supplies power to

the I/O Modules.

The ANB10S and ANB10D are called “ESB Bus Node

Units” (Local Nodes) because they are connected

directly to a FCU via an ESB bus, whereas the

ANR10S and ANR10D are called “ER Bus Node Units”

(Remote Nodes) because they are connected to an

EB401 (ER Bus Interface Master Module) installed in

an ESB Bus Node Unit via an ER bus.

A power supply module, bus interface module and I/O

module are installed in the node unit.

A single or dual-redundant configuration can also

be selected for the node unit. For details on the

I/O modules, refer to the General Specifications of

the I/O Modules (for FIO) (GS 33M50F25-40E, GS

33M50F30-40E, GS 33M50F40-40E, GS 33M50G10

40E, GS 33M50G20-40E).

 HARDWARE SPECIFICATIONS

F01.ai

For the installation specifications and environmental conditions that are common to the systems, refer to “FIO System

Overview (GS 33M50F10-40E).”

 No. of Node Units Connectable

Type of Equipment

Compact Field Control Unit (for FIO)

Basic Field Control Unit (for FIO, for Vnet/IP)

Enhanced FCS with expanded databases

Basic Field Control Unit (for FIO, for Vnet/IP) +

Application Capacity Expansion Package

Others

Local Node Units

Connected per FCU

Remote Node Units

Connected per FCU

Total Number of

Local and Remote

Node Units Connected

per FCU

Max. 3/FCU

Max. 10/FCU

Max. 9/FCU

Max. 10/FCU

*1:

Up to 8 remote nodes per ER bus can be connected.

 Remote Node Connection

ER Bus: Max.4/FCU

Max. 3/FCU

Max. 14/FCU (*1)

Max. 14/FCU (*1)

Max. 9/FCU (*1)

Max. 3/FCU

Max. 15/FCU

Max. 14/FCU

Max. 10/FCU

When connecting a Remote Node to a Local Node or Compact Field Control Unit (for FIO), install ER Bus Interface

Mater Module (EB401) to the Local Node or Compact Field Control Unit (for FIO).

To make single configuration, EB401 must be installed in an odd-number slot, and make a space on the right side of

the installed EB401.

See “ER Bus Interface Master Module (for FIO)” (GS 33M50F25-40E) for further information

 Local Node Connection

When connecting a Local Node to Compact Field Control Unit (for FIO), install ESB Bus Coupler Module (EC401) to

Compact Field Control Unit (for FIO).

EC401 must be installed in slot 7 and slot 8. To make single configuration, EC401 must be installed in slot 7. and Slot

8 must be empty.

 Power Supply

(Specify with Suffix Codes)

Voltage:

100-120 V AC, Frequency: 50/60 Hz

Voltage:

Voltage:

220-240 V AC, Frequency: 50/60 Hz

24 V DC

 Electric Power Consumption

100-120 V AC: 200 VA, 120 W

220-240 V AC: 230 VA, 120 W

24 V DC:  5.5 A

 Weight

10 kg (incl. 8 IOMs)

 Regulatory Compliance

For the detailed information of following standards, see “System Overview” (GS 33M01A10-40E).

Safety Standards

[CSA]

[CE Marking]

(for 100-120 V AC and 24 V DC power supply)

(for 100-120 V AC, 220-240 V AC and 24 V DC power supply)

EMC Conformity Standards

[CE Marking]

[C-Tick Marking]

[KC Marking]

(for 100-120 V AC, 220-240 V AC and 24 V DC power supply)

(for 220-240 V AC and 24 V DC power supply)

(for 100-120 V AC, 220-240 V AC and 24 V DC power supply)

Standards for Hazardous Location Equipment

[CSA Non-Incendive]

[FM Non-Incendive]

[Type n]

(Remote Node only, for 100-120 V AC and 24 V DC power supply)

(for 100-120 V AC, 220-240 V AC and 24 V DC power supply)

(for 24 V DC power supply)

 CONFIGURATION

 Rack Mounting

Card configuration

Power Supply Module:  Two modules in case of a dual-redundant configuration.

Power supply to the I/O Modules, and supply power to the transmitters.

The power supply terminals use M4 screws.

ESB Bus Interface Slave Module (SB401):  Two modules in case of a dual-redundant configuration.

ER Bus Interface Slave Module (EB501):  Two modules in case of a dual-redundant configuration.

 LIMITATIONS OF INSTALLATION AND NOTICES FOR INSTALLATION

For installing I/O modules in node unit, the quantity and allocation are limited.  Also, when installing a node unit to

the dedicated cabinet, there are limitations of installation under the ambient operating temperature conditions. When

modules with built-in barriers are installed in any node unit, an insulating partition (Part No. T9083NA) must be

installed.

For details, please refer to “Limitations and Precautions for Installation” (GS 33M50F10-40E)



  • Woodward MFR300-71M 8444-1063
  • SPM-D2-1010B/X analog speed/voltage bias 8440-2168
  • Woodward SPM-D2-1040B/X analog speed/voltage bias 8440-2171
  • Woodward SPM-D2-1010B/N wide range power supply 8440-2174
  • Woodward SPM-D2-1040B/N wide range power supply 8440-2175
  • Woodward SPM-D2-1010B /110VAC sensing 8440-2166
  • Woodward SPM-D2-1040B /400VAC sensing 8440-2164
  • Woodward DTSC-200A 8440-2297
  • Woodward DTSC-200-55B/K38 8440-2155
  • Woodward DTSC-200-51B 8440-1867 8440-1868
  • Woodward 8445-1049 8445-1048 Converter, 1x FO to CAN
  • Woodward easYlite-200 8446-1007 LED Lamp Expansion Module
  • Woodward IKD-OUT-16 16 DO Expansion Card 8440-2306
  • Woodward IKD-IN-16 16 DI Expansion Card 8440-2307
  • Woodward IKD1M 8 DI/8 DO Expansion Card 8440-2116
  • Woodward easYview-07-30 8446-1071
  • Woodward easYFLEX-3400XT-P2 (GAP) 8440-2217
  • Woodward easYFLEX-3400XT-P2 (GAP) 8440-2217
  • Woodward easY-I-3400XT-P1 8440-2293
  • Woodward easY-I-3500XT-P1 8440-2292
  • Woodward MSLC-2XT 8440-2298 Master Synchronizer and Load Control
  • Woodward DSLC-2XT 8440-2299 Digital Synchronizer and Load Control
  • Woodward: GC-3400XT-P1 8440-2267 Group Controller
  • Woodward: LS-612XT-P2 8440-2317
  • Woodward: CONTROL-LS-612XT-P1,8440-2222 Cabinet back mounting
  • Woodward: LS-522-1/P1 8440-2179
  • Woodward: LS-522-5/P1 8440-2151
  • Woodward: LS-512-1/P1 8440-2181
  • Woodward: LS-512-5/P1 8440-2153
  • Woodward: LS-521-1/P1 8440-2178
  • Woodward: CONTROL-LS-521-5/P1 8440-2150
  • Woodward: LS-511-1/P1 8440-2180 Circuit Breaker Control & Protection
  • Woodward: CONTROL-LS-511-5/P1 8440-2152 Circuit Breaker Control & Protection
  • Woodward easYgen-3500XT-P2-LT-RENTAL 8440-2291 Genset Control for
  • Woodward eeasYgen-3500XT-P2-RENTAL 8440-2290
  • Woodward easYgen-3200XT-RENTAL 8440-2285
  • easYgen-3500XT-P2-K58 8440-2318
  • easYgen-3500XT-P2-LT 8440-2089
  • Woodward easYgen-3500XT-P2 8440-2088 Genset Controller
  • Woodward: easYgen-3500XT-P1-LT 8440-2086
  • Woodward: easYgen-3500XT (P1) 8440-2085
  • Woodward: easYgen-3400XT (P2), Genset Controller 1A/5A 8440-2087
  • Woodward: easYgen-3400XT (P1) 8440-2084
  • Woodward 8440-2082 EasyGen 3200XT Genset Controller
  • Woodward: easYgen-3200XT (P1/LT) 8440-2083
  • Woodward: easYgen-3100XT 8440-2081
  • Woodward: easYgen-2500 (1A/P1) K33 8440-2096
  • Woodward easYgen-2500-5/P1-K33 Rental Version 8440-2029
  • Woodward easYgen-2500-1/P1 8440-1860
  • Woodward easYgen-2500-5/P1 8440-1884
  • Woodward easYgen-2300-1/P2 8440-2123 Controller
  • Woodward easYgen-2300-5/P2 8440-2058
  • Woodward 2300E – Ordinary Locations 8273-1017
  • Woodward Vertex Compressor Control 8200-1370
  • MicroNet Safety Module - Bulkhead Mount 8237-2492 Woodward
  • ProTech TPS - Bulkhead Mount Independent Relays 8237-2602
  • Woodward ProTech-GII - Bulkhead Mount Independent Relays 8237-2594
  • ABB AX410, AX411, AX413, AX416, AX418, AX450, AX455 and AX456 Single and dual input analyzers for low level conductivity
  • ABB AX411/511010/STD Single and dual input analyzers
  • Woodward ProTech-SX - Panel Mount, HV/LV 8237-1242 8237-1243
  • Woodward SPC Servo Position Controller 8200-226 8200-227
  • Woodward Peak200 – Bulkhead Mount, LV 8200-1500
  • Woodward 505HT for Pelton Turbines 8200-1400, 8200-1401
  • Woodward 2301E-HT Hydro (Francis Turbines) P/N 8237-2046
  • Woodward 8273-1013 8273-1014 Digital Electronic Load Sharing
  • Control Panel 9907-2024 Woodward
  • ABB REF630 UBFNAAABBBAZANBBXB Feeder Protection and Device
  • ABB PPD513 A2A-11165 High-performance controller
  • UniOP CP10G-04 CP10G-04-0045 Interface Module
  • UNIOP MKDR-04-0021 Monochrome LCD (with Contrast Control)
  • UNIOP eTOP03-0046 Monochrome LCD (STN)
  • UNIOP MKDR-16-TA-0045 HMI TOUCH SCREEN
  • UNIOP Operator Interface Display MD02R-04-0042
  • UniOP Display Screen eTOP20C-0050 eTOP20C
  • UniOp eTOP05-0045 eTOP05. eTOP05P Operator Interface Touch Panel
  • UNIOP ETOP11-0050 HMI 5.6Color Operator Interface Touch Panel
  • UniOp eTOP306 Panel
  • UniOP eTOP308 ETOP308U301 HMI Panel
  • UniOP ePALM10-0061 Handheld Robot Trainer
  • UniOP CP01R-04 CP05R-04 and CP01F-02
  • Uniop MD02R-04 - MD02R-04-0045 Industrial PLC Workstation
  • Uniop Cp02r-04-0021 Operating Interface
  • UniOP ECT-16-0045 High-Performance Color Touchscreen HMI
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD04-0046 Compact Industrial Interface
  • UniOP BKDR-16 High-Reliability Monochrome Operator Interface
  • UniOP MKDR-04-004 Control Unit Panel
  • UniOP eTOP515 Series 500 HMI
  • Woodward 9907-1199 Advanced CPC-II Current-to-Pressure Converter
  • Woodward 8200-1300 High-Precision 505D Steam Turbine Controller
  • ABB PFSK130 3BSE002616R1 Core Signal Conditioning Unit
  • ABB PFSK165 3BSE027778R1 VP74201-933CW07 Signal Processing and Communication Unit
  • ABB PFSK164 3BSE021180R1 Tension sensor module and processing board
  • ABB 3BSE006505R1 PFSK142 Control board
  • ABB PFSK160A 3BSE009514R1 Regulated High-Capacity 24V DC
  • ABB PFSK162 3BSE015088R1 Signal Conditioning and Processing Board
  • ABB PFSK152 3BSE018877R1 Signal concentrator board
  • ABB PFSK151 3BSE018876R1 High-performance signal processing unit
  • ALSTOM PIB1201A 3BEC0067 Power Interface Board (PIB)
  • ALSTOM PIB310 3BHB0190 Adapter Module / Printed Circuit Board (PCB)
  • ALSTOM PIB102A 3BEB0180 Communication Card / PCB Module
  • ALSTOM BGTR8HE 24491276A1004 High-Frequency Power Controller / Rack Module
  • ALSTOM LC105A-1 Digital Discrete Output (Relay)
  • ALSTOM IR139-1 High-Efficiency Inverter / Control Board
  • ALSTOM AM164 Analog Output / Remote I/O
  • ALSTOM LE109A-1 Power System Control and Monitoring Module
  • ALSTOM UT150-1 PID temperature controller / process control board
  • ALSTOM AL132 AL132A STO0982E01 Control Motherboard / CPU Card
  • ALSTOM AS111-1 Analog Output (AO) Module
  • WATLOW AH116-2 Servo Drive / Control Module
  • WATLOW V4555724-0100 Electromechanical Contactor /Power Switch
  • Alstom KCEU142 Digital Protection Relay
  • ALSTOM MMLG01 Test block
  • WATLOW 999D,999A Digital/Analog Dual-Channel Base Unit
  • WATLOW 998D 998A Digital/Analog Dual-Channel Base Unit
  • WATLOW 999D-11FF-AARG Dual-channel digital unit with universal process outputs
  • WATLOW Wattlo 998D-22KK-ARRG is a high-performance dual-channel digital controller
  • WATLOW 996A Single-loop controller
  • WATLOW 996D-11CC-CUGR Single-loop digital controller
  • WATLOW 996D Single-Channel Digital Temperature/Process Controller
  • WATLOW 997D Digital Dual-Channel Base Unit
  • WATLOW 997A Analog Dual-Channel Variant
  • WATLOW DAC / SDAC Digital-to-Analog / Serial-to-Analog Modules
  • WATLOW MLS300-OIT Operator Interface Terminal (Keypad/Display),Discontinued
  • WATLOW CIM300 Communication Interface Module (EIA-232/485),Discontinued
  • WATLOW MLS300-CIM Control Interface Module
  • WATLOW MLS300-AIM,Analog Input Module (16-channel expansion),Discontinued
  • WATLOW MLS300-PM Processor Module (Central CPU),Discontinued