KONG -Y
NameDescriptionContent
Location:

Woodward easYgen-1400 Technical Manual Genset Control

From:Woodward | Author:kongjiang | Time :2026-03-06 | 748 Browse: | 🔊 Click to read aloud ❚❚ ▶ | Share:

easYgen-1400

Technical Manual

Genset Control

Copyright And Disclaimer

Disclaimer

All information and instructions in this manual have been provided under due

consideration of applicable guidelines and regulations, the current and known state of the

art, as well as our many years of in-house experience. Woodward assumes no liability for

any damages due to:

• Failure to comply with the instructions in this manual

• Improper use / misuse

• Willful operation by non-authorized persons

• Unauthorized conversions or non-approved technical modifications

• Use of non-approved spare parts

The originator is solely liable for the full extent for damages caused by such conduct. The

obligations agreed-upon in the delivery contract, the general terms and conditions, the

manufacturer’s delivery conditions, and the statutory regulations valid at the time the

contract was concluded, apply.

Copyright

This manual is protected by copyright. No part of this manual may be reproduced in any

form or incorporated into any information retrieval system without written permission of

Woodward GmbH.

Delivery of this manual to third parties, duplication in any form - including excerpts - as

well as exploitation and/or communication of the content, are not permitted without a

written declaration of release by Woodward GmbH

Actions to the contrary will entitle us to claim compensation for damages. We expressly

reserve the right to raise any further accessory claims.

1.3

Service And Warranty

Opening the device will nullify any warranty!

Any such unauthorized modifications

• constitute "misuse" and/or "negligence" as per the product warranty

• thereby exclude warranty coverage for any resulting damage, and

• invalidate product certifications or listings.

Our Customer Service is available for technical information. Please see page 2 for contact

details.

In addition, our employees are interested in any new information and experiences that

arise from usage and could be valuable for improving our products.

1.4

1.4.1

Safety

Intended Use

The easYgen unit has been designed and constructed solely for the intended use

described in this manual.

• Intended use requires operation of the control unit within the range outlined in the

specifications listed in ╚═▷ “8 Technical Specifications”.

• Steps to be taken for commissioning are outlined in ╚═▷ “6 Commissioning”.

• Intended use includes compliance with all instructions and safety notes presented in

this manual.

• Any use which exceeds or differs from the intended use shall be considered improper

use.

• No claims for any kind for damage will be considered if such claims result from

improper use.

1.4.2 Personnel

This manual specifies the personnel qualifications required for the different areas of work,

listed below:

•Well trained for electrical installations. •

•Aware of the local safety regulations. •

•Experienced in working with electronic measuring and control devices. •

•Allowed to manage the controlled (engine/generator) system. •

The workforce must only consist of persons who can be expected to carry out their work

reliably. Persons with impaired reactions due to, for example, the consumption of drugs,

alcohol, or medication are prohibited.

When selecting personnel, the age-related and occupation-related regulations governing

the operating location must be observed.

2

System Overview

General notes

The easYgen is a stand-alone genset controller with measuring, monitoring, and breaker

control functionality. It comes with an easily mountable plastic housing covering a

thoroughly tested electronic-electrical system.

Display and buttons of the HMI offer access to states and values, as well as access to the

application. Password protection enables the assignment of multiple operation access

levels. Remote access, monitoring, visualization, and configuration are possible via

integrated interfaces. Communication between easYgens using PLC control or as a

network member offers an enhanced system management range; additionally supported

by easy to implement accessories

2.1

Display and Status Indicators

General Notes

HMI and the configuration software enable access to control, settings, and visualization.

The front panel offers a number of functionally defined buttons and a set of menu

management buttons. LEDs visualize fixed states, the graphic display works together with

the menu management buttons to show all necessary information

Features and Functions of both easYgen-400 and -1400

Both, easYgen-400 and easYgen-1400. are very similar in hardware and software. The

easYgen-1400 is the device with the higher functionality. For purposes of comparison and

better differentiation, both are described below.

easYgen-400 is intended to be used for single automation systems, auto start/stop of

the unit is performed using a remote signal.

easYgen-1400 has all the functions of the easYgen-400 as well as automatic mains

failure function (AMF), which is particularly well-suited for single automation systems that

include mains and generator

Key characteristics

• With ARM-based 32-bit SCM, highly integrated hardware, high reliability level.

• Multilingual interface (English, Chinese, Spanish, Russian, Portuguese, Turkish,

  • Beckhoff CX2500-B310 | Fieldbus slave module PROFIBUS for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-0070 | USB 3.0 module for CX20xx, CX52xx, CX53x0. CX56x0
  • Beckhoff CX2500-0062 | 2.5 Gbit Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-1061 | Power over Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-1060 | Ethernet module for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX2500-0031 | Serial Interface RS485/RS422
  • Beckhoff CX2500-0030 | Serial Interface RS232 for CX20xx, CX52x0. CX53x0. CX56x0
  • Beckhoff CX5230-0195 CPU module
  • Beckhoff CX5230-0190    CPU module
  • Beckhoff CX5230-0175    CPU module,
  • Beckhoff CX5230-0170  CPU module
  • Beckhoff CX5230-0100    CPU module, no operating system, no TwinCAT
  • Beckhoff CU8130-0240 | UPS modul, battery-backed
  • Beckhoff CU8130-0120 | UPS module, battery-backed
  • Beckhoff CU8110-0120 | UPS module, capacitive
  • Beckhoff CU8110-0060 | UPS module, capacitive
  • Beckhoff CX5130-0195    CPU module
  • Beckhoff CX5130-0190    CPU module
  • Beckhoff CX5130-0185 CPU module
  • Beckhoff CX5130-0170    CPU module
  • Beckhoff  CX5130-0163 CPU module, Microsoft Windows 10 IoT Enterprise 2019 LTSC, 32 bit
  • Beckhoff  CX5130-0162    CPU module
  • Beckhoff CX5130-0161  CPU module
  • Beckhoff CX5130-0160    CPU module
  • Beckhoff CX5130-0155  CPU module
  • Beckhoff CX5130-0150    CPU module
  • Beckhoff CX5130-0143 CPU module
  • Beckhoff CX5130-0142 CPU module
  • Beckhoff CX5130-0140    CPU module
  • Beckhoff CX5130-0135 CPU module
  • Beckhoff CX5130-0130 CPU module
  • Beckhoff CX5130-0125    CPU module
  • Beckhoff CX5130-0123    CPU module
  • Beckhoff CX5130-0122    CPU module
  • Beckhoff CX5130-0121 CPU module
  • Beckhoff CX5130-0115    CPU module,
  • Beckhoff CX5130-0113    CPU module
  • Beckhoff CX5130-0112   CPU module
  • Beckhoff CX5130-0111   CPU module
  • Beckhoff CX5130-0110 CPU module, Microsoft Windows Embedded Compact 7. no TwinCAT
  • Beckhoff CX5130-0100  CPU module, no operating system, no TwinCAT
  • DEIF FAS-113DG Synchronisation & circuit breaker closing
  • DEIF FAS-115DG Synchronisation & circuit breaker closing
  • DEIF HAS-111DG Synchronisation & circuit breaker closing
  • DEIF LSU-122DG Load sharing, paralleling & operation
  • DEIF LSU-114DG Load sharing, paralleling & operation
  • DEIF LSU-113DG Load sharing, paralleling & operation
  • DEIF LSU-112DG Load sharing, paralleling & operation
  • DEIF RMF-112D Frequency relay
  • DEIF RMC-142D Current relay
  • DEIF RMC-132D Current relay
  • DEIF RMC-131D Current relay
  • DEIF RMC-122D Current relay
  • DEIF RMC-121D Current relay
  • DEIF RMC-111D Current relay
  • DEIF MVR-V211 Busbar Protection
  • DEIF MVR-T257 Transformer Differential Protection
  • DEIF MVR-T256 Transformer Differential Protection
  • DEIF MVR-T216 Transformer Differential Protection
  • DEIF MVR-T215 Transformer Protection
  • DEIF MVR-M257 Motor Differential Protection
  • DEIF MVR-M255 Motor Protection
  • DEIF MVR-M215 Motor Protection
  • DEIF MVR-M210 Motor Protection
  • DEIF MVR-G257 Generator Differential Protection
  • DEIF MVR-G215 Generator Protection
  • DEIF MVR-F255 Directional Feeder Protection
  • DEIF MVR-F215 Directional Feeder Protection
  • DEIF MVR-F210 Feeder Protection
  • DEIF MVR-F205 Directional Feeder Protection
  • DEIF MVR-F201 Basic Feeder Protection
  • DEIF MVR-200 series Medium Voltage Relay
  • DEIF MDR-2 Multi-differential relay
  • DEIF LMR-122D Loss of mains relay
  • DEIF LMR-111D Loss of mains relay
  • DEIF APU-4 Advanced G59 and G99 protection unit
  • DEIF iE 650 PLC - The most robust programmable automation controller available
  • DEIF iE 350 PLC - Programmable Automation PLC Controller
  • DEIF iE 250 PLC Versatile and modular intelligent energy PLC controller
  • DEIF PPM-3 EDG Protection and Power Management
  • DEIF AGC 3X 4198000234E AUTOMATIC GENSET CONTROLLER
  • SAUTER ASF123 Damper actuator with spring return
  • SAUTER ASF122 Damper actuator with spring return
  • SAUTER ASF113F122 Damper actuator with spring return
  • SAUTER ASF113F120 Damper actuator with spring return
  • SAUTER ASF112F122 Damper actuator with spring return
  • SAUTER ASF112F120 Damper actuator with spring return
  • SAUTER ASM 124/134 series - ASM134F130 Damper actuator
  • SAUTER ASM 124/134 series - ASM134SF132 Damper actuator
  • SAUTER ASM 124/134 series - ASM124SF132 Damper actuator
  • SAUTER ASM 124/134 series - ASM124F122 Damper actuator
  • SAUTER ASM 124/134 series - ASM124F120 Damper actuator
  • SAUTER Valve actuator ASM 105S/115S series ASM115SF152
  • SAUTER Valve actuator ASM 105S/115S series ASM105SF152
  • SAUTER Valve actuator ASM 105S/115S series ASM115SF132
  • SAUTER Valve actuator ASM 105/115 series ASM105SF132
  • SAUTER Valve actuator ASM 105/115 series ASM115F122
  • SAUTER Valve actuator ASM 105/115 series ASM115F120
  • SAUTER Valve actuator ASM 105/115 series ASM105F122
  • SAUTER Valve actuator ASM 105/115 series ASM105F120
  • SAUTER Valve actuator ASM 105/115 series ASM105F10
  • SAUTER AKF113S Rotating actuator AKF 112/113 series
  • SAUTER AKF113F122 Rotating actuator AKF 112/113 series
  • SAUTER AKF113F120 Rotating actuator AKF 112/113 series
  • SAUTER AKF112F122 Rotating actuator AKF 112/113 series
  • SAUTER AKF112F120 Rotating actuator AKF 112/113 series
  • SAUTER AKM115SAF332: Smart Actuator for ball valve, BACnet/IP
  • SAUTER AKM115SAF232  Rotating Actuator  AKM 115SA Smart Actuator
  • SAUTER AKM115SF152  Rotating Actuator  AKM 105S/115S Series
  • SAUTER AKM115SF132  Rotating Actuator  AKM 105S/115S Series
  • SAUTER AKM105SF132  Rotating Actuator  AKM 105S/115S Series
  • SAUTER AKM115F122 Rotating actuator  AKM 105/115 series
  • SAUTER Rotating actuator  AKM 105/115 series AKM115F120
  • SAUTER Rotating actuator  AKM 105/115 series AKM105F122
  • SAUTER Rotating actuator  AKM 105/115 series  AKM105F120
  • SAUTER Continuous actuator for unit valves, with stroke AXS215S
  • SAUTER Linear valve actuator AXT/AXS series AXT211
  • SAUTER Linear valve actuator AXT/AXS series AXT201
  • SAUTER Linear valve actuator AXM/AXF series AXF217S
  • SAUTER Linear valve actuator AXM/AXF series AXM217S
  • SAUTER AXM217SF404 is an electric actuator for unit valves.
  • SAUTER AXM217SF402 is an electric actuator for unit valves.
  • SAUTER Linear valve actuator AXM/AXF series AXM217
  • SAUTER Linear valve actuator AVF 124/125 series AVF125S
  • SAUTER Linear valve actuator AVF 124/125 series AVF124S
  • SAUTER AVM322S-R Linear valve actuator AVM 234S series
  • SAUTER AVM322-R Linear valve actuator AVM 234S series
  • SAUTER AVM322SF132 Linear valve actuator AVM 234S series