KONG -Y
NameDescriptionContent
Location:

Woodward easYgen-400 Operation Manual Genset Control

From:Woodward | Author:kongjiang | Time :2026-03-06 | 872 Browse: | 🔊 Click to read aloud ❚❚ | Share:

easYgen-400

Operation Manual

Genset Control

Rev. Date Editor Changes

F 2023-08 MK NEW Software Version 2.1.0.8

•Suitable for new LCD display •

E 2021-06 MK NEW Software Version 2.1.0.7

•needed ToolKit-SC Version 1.5.1.5 or higher •

NEW features & functions

•Added output ports: 27 Preheat until safety, 28 Preheat until •

warming, 29 Preheat until cranking

Corrections/Repairs

•None •

D 2020-11 TM NEW Software Version 2.1.0.6

•needed ToolKit-SC Version 1.5.1.3 or higher •

NEW features & functions

•Support for HATZ ECU •

Corrections/Repairs

•None •

C 2020-11 TM NEW Software Version 2.1.0.5

NEW features & functions

• ID 835 Enumeration "emergency shutdown" function for discrete •

inputs

• ID 846 Action (alarm class) from analog inputs monitoring is now •

configurable

• ID 1099 Additional logic for maintenance counters •

• ID 1098 Semi-Auto mode for AMF start •

• ID 1103 Unbalanced load alarm •

Corrections/Repairs

• ID 837 Breaker logic "constant" de-energizes with breaker alarm •

• ID 931 Corrected Volvo ECU 50/60 Hz selection

Rev. Date Editor Changes

• ID 1000 Reference values for rated "active power" and "reactive •

power"

B 2019-05 PW NEW Software Revision 2.0.0.1 and ToolKit-SC version 1.5.0.4

Corrections/Repairs

•Fixed the following in HMI software: •

◦fixed the version name to 4 digits; ◦

◦possibility to close GCB when engine not running; ◦

◦kvar spelling; ◦

◦ impossibility to mute the horn with easYlite-200; ◦

◦HMI user defined sensor curves displaying messy codes in ◦

other languages

◦after gen closed, if changed breaker close delay by Toolkit-◦

sc, 6550 countdown error occurred in HMI;

◦when change to OEM plant theme and Terminal users ◦

theme, press close/open button in manual mode, error

occurred in breaker page;

◦Horn/Alarm Acknowledge / Alarm reset function ◦

◦"Traditional Chinese" implemented ◦

◦changed name easYgen400/easYgen1400 to easYgen-400/ ◦

easYgen-1400 in controller information page;

◦status LED not turning on if the "Conventional Engine" was ◦

selected, easYgen and genset in STOP condition, START

button pressed;

◦maintenance counter resetting ◦

◦Polish translation errors ◦

◦modified configuration of auto test mode, including number ◦

of input ports, LED display order, and level sensor changed

from flexible sensor to resistor type sensor;

◦ J1939 standard and setpoint idle ◦

◦Volvo EMS2 50/60Hz rated speed selection ◦

◦overload monitoring not using the "return" value; ◦

◦Volvo EMS2 rated frequency selection and rated speed ◦

modification;

◦mains breaker warning in MAN mode; ◦

◦operation mode changing from MAN with closed GCB to ◦

MCB;

◦breaker status in MAN mode; ◦

◦removed all ECU types with Modbus; ◦

◦removed “Baud rate and Modbus slave ID” parameters; ◦

◦parameter naming change: in order to align with ToolKit, ◦

changed “Current” to “Limit” and “Low fuel level” to “Fuel

level warning” in HMI parameter config screen;

•Fixed the following in ToolKit-SC

Rev. Date Editor Changes

◦fixed the version name of 2 digits displayed on ToolKit to 4 ◦

digits;

◦removed WWDMODEM-3G related parameters; ◦

◦removed “emergency stop input”; ◦

◦removed “Baud rate and Modbus slave ID”parameters; ◦

◦removed all ECU types with Modbus. ◦

A 2018-11 PC Describes device implemented software version 1.8 and

ToolKit-SC version 1.4.0.2

Additional markings

To highlight instructions, results, lists, references, and other elements, the following

markings are used in these instructions:

Marking Explanation

__▶ Step-by-step instructions

⇨ Results of action steps

╚═▷ References to sections of these instructions and to other

relevant documents

• Listing without fixed sequence

»Buttons« Operating elements (e.g. buttons, switches), display

elements (e.g. signal lamps)

»Display« Screen elements (e.g. buttons, programming of function

keys)

[Screen xx / Screen xy /

Screen xz] ...

Menu path.

The following information and setting refer to a page on

the HMI screen or ToolKit located as described here.

Some parameters/settings/screens are available only

either in ToolKit or on the HMI/display

1.2 Copyright And Disclaimer

Disclaimer

All information and instructions in this manual have been provided under due

consideration of applicable guidelines and regulations, the current and known state of the

art, as well as our many years of in-house experience. Woodward assumes no liability for

any damages due to:

•Failure to comply with the instructions in this manual •

• Improper use / misuse •

•Willful operation by non-authorized persons •

•Unauthorized conversions or non-approved technical modifications •

•Use of non-approved spare parts •

The originator is solely liable for the full extent for damages caused by such conduct. The

obligations agreed-upon in the delivery contract, the general terms and conditions, the

manufacturer’s delivery conditions, and the statutory regulations valid at the time the

contract was concluded, apply.

Copyright

This manual is protected by copyright. No part of this manual may be reproduced in any

form or incorporated into any information retrieval system without written permission of

Woodward GmbH.

Delivery of this manual to third parties, duplication in any form - including excerpts - as

  • ADLINK Peripherals & Accessories cPCI-8301
  • ADLINK Peripherals & Accessories cPCI-3W10
  • ADLINK Analog Output cPCI-6208/6216 Series
  • ADLINK Multi-Function DAQ cPCI-9116
  • ADLINK 3U CompactPCI Blades CT-3620
  • ADLINK 3U CompactPCI Blades cPCI-3620
  • ADLINK 3U CompactPCI Blades cPCI-3620
  • ADLINK 3U CompactPCI Blades cPCI-3630
  • ADLINK 3U CompactPCI Blades cPCI-3640 Series
  • 3U CompactPCI Blades cPCI-3520 Series
  • ADLINK IMB-M42H ATX Motherboards
  • Adlink PCIe-GIE74 /PCIe-GIE74V Frame Grabbers / Video Capture Cards
  • ADLINK USB-1605 Removable screw terminal blocks or high-density D-Sub
  • Adlink ETX-NR667-L7400/LXE ETX Module
  • ADLINK NuPRO-842LV/P industrial control motherboard
  • ADLINK cPCI-8994 Serial Communication
  • ADLINK / PCI-7432 Digital I/O
  • ADLINK IEC-915GV Compact industrial-grade fanless embedded system
  • ADLINK ADLINK, PLX / PCI-7296 Digital I/O
  • ADLINK HPCI-14S12U 0040 Backplane Selection Guide
  • ADLINK MXE-5500 /MXE-5501/M16G (G) Fanless Embedded Computer
  • Adlink Multi-Function DAQ PCI-9112
  • ADLINK NuPRO-852LV Control Board
  • ADLINK CompactPCI cPCI-7432R Digital I/O Module
  • ADLINK NUPRO-E320LV PICMG Single Board Computers
  • ADLINK PICMG Single Board Computers NuPRO-E72
  • ADLINK PICMG Single Board Computers NuPRO-865
  • Vibro-Meter Rack VM600SYSMK2-ABE04x 6U 19-inch rack Mk2 system
  • Vibro-Meter Relay expansion RLC16 Mk2 SIL2 (single card) 600-044L
  • Vibro-Meter Relay expansion RLC16 Mk2 SIL2 600-04
  • Vibro-Meter Relay expansion RLC16 Mk2 600-045L
  • Vibro-Meter Relay expansion RLC16 Mk2 600-045
  • Vibro-Meter I/O interface card  IOCN Mk2    600-051
  • Vibro-Meter CPU controller   CPUM Mk2  600-050
  • Vibro-Meter I/O interface card    IOC10 Mk2 (rear card)    600-046
  • Vibro-Meter Temperature / Analog Acquisition  AMC10 Mk2  600-042
  • Vibro-Meter I/O interface card IOC4 Mk2 600-043
  • Vibro-Meter Protective measuring card MPC4 Mk2 SIL2 601-041-A10
  • Vibro-Meter Protective measuring card MPC4 Mk2 601-041-A0
  • Vibro-Meter PSU-VM600 VM600 Rack Power Module
  • Vibro-Meter ABE056 - 1U ultra-thin single-rack
  • Vibro-Meter ABE046 - 6U 19-inch rack
  • Vibro-Meter ABE045 - 6U 19-inch rack
  • Vibro-Meter ABE044 - 6U 19-inch rack (with expansion slots)
  • Vibro-Meter ABE042 6U 19-inch rack (4 slots)
  • Vibro-Meter I/O interface card XIO16T
  • Vibro-Meter XMC16 16-channel combustion monitoring card
  • Vibro-Meter XMV16 - 16-channel vibration condition monitoring card
  • Vibro-Meter RLC16 Relay Card
  • Vibro-Meter IRC4 Intelligent Relay Card
  • Vibro-Meter IOCR2 input/output rear interface card
  • Vibro-Meter CPUR2 Central Processing and Controller Card
  • Vibro-Meter I/O interface card  -  IOCR
  • VIBRO-METER CPU controller CPUR
  • VIBRO-METER IOCN 200-585-000-322 I/O interface card
  • VIBRO-METER IOCN 200-585-000-321 I/O Interface Card
  • VIBRO-METER 200-595-074-323 VM600 system CPU management card, non-redundant
  • VIBRO-METER CPUM 200-595-074-322 CPU Controller
  • VIBRO-METER CPU controller CPUM 200-595-070-321
  • Vibro-Meter IOC8T VM600 Mk1 I/O Interface Card
  • Vibro-Meter AMC8 Analog Monitoring Card
  • VIBRO-METER IOC4G2 I/O interface card
  • VIBRO-METER MPC4G2 Protective measuring card
  • VIBRO-METER IOC4T 200-560-101-017 VM600 Mk1 Isolated I/O Interface Card, equipped with MPC4
  • VIBRO-METER IOC4T 200-560-101-015 VM600 Mk1 interface card
  • VIBRO-METER IOC4T 200-560-000-114 I/O interface card
  • VIBRO-METER IOC4T 200-560-000-113 I/O interface card
  • VIBRO-METER IOC4T 200-560-000-111 Sensor wiring
  • VIBRO-METER MPC4 200-510-072-212 Protection Measurement Card
  • VIBRO-METER MPC4 200-510-071-114 Protective Measurement Card
  • VIBRO-METER 200-510-071-111 4-channel vibration protection + 2-speed channels
  • VIBRO-METER 200-510-070-111 4-channel vibration protection + 2-speed channels
  • ADLINK PICMG Single Board Computers NuPRO-E315
  • ADLINK High Speed Link (HSL) PCI-7853
  • ADLINK Digital I/O PCIe-7432
  • ADLINK Mini-ITX Embedded Boards AmITX-AL-I
  • ADLINK 6U CompactPCI 2.0 Blades cPCI-6860A
  • ADLINK NuPRO-900A PICMG Single Board Computers
  • ADLINK Analog Output PCI-6308 Series
  • ADLINK USB DAQ USB-2405
  • ADLINK CRR-LX800-E-500 Compact Industrial Computer Module (COM)
  • ADLINK 15-slot 6U PXI/CompactPCI Chassis with AC PXIS-3320
  • ADLINK NUPRO-842 PICMG Single Board Computers
  • ADLINK PCI-8124-C Advanced 4-CH Encoder Card
  • ADLINK PCI-8102 Centralized Motion Controllers PCI-8102
  • ADLINK PCIe-7200 High-Speed DIO
  • SEL SEL-7201 Feeder Protection Panel
  • SEL SEL-7206 Distribution Bus Differential Protection Panel
  • SEL SEL-4388 Mirrored Bits Tester
  • SEL SEL-T4287 Traveling-Wave Test System
  • SEL SEL-4000 Relay Test System
  • SEL SEL-9510 Control Switch Module
  • SEL SEL-9502 Contact Arc Suppressor
  • SEL SEL-9501 Contact Arc Suppressor
  • SEL SEL-2652 Trip Coil Monitor
  • SEL SEL-2894 Interface Converter
  • SEL SEL-2890 Ethernet Transceiver
  • SEL SEL-2886 EIA-232 to EIA-485 Interface Converter
  • SEL SEL-9220 Fiber-Optic Adapter for SEL-300 Series Relays
  • SEL SEL-2824 Multimode Fiber-Optic EIA-485 Transceivers
  • SEL SEL-2820 Multimode Fiber-Optic EIA-485 Transceivers
  • SEL SEL-2815 Fiber-Optic Transceiver/Modem
  • SEL SEL-2814 Fiber-Optic Transceivers With Hardware Flow Control
  • SEL SEL-2812 Fiber-Optic Transceivers With IRIG-B
  • SEL SEL-2810 Fiber-Optic Transceivers With IRIG-B
  • SEL SEL-2831 Single-Mode Fiber-Optic Transceiver/Modem
  • SEL SEL-2830 Single-Mode Fiber-Optic Transceiver/Modem
  • SEL SEL-2829 Single-Mode Fiber-Optic Transceiver/Modem
  • SEL SEL-C805 200 µm Multimode Fiber-Optic Cable
  • SEL SEL-C804 Multimode Arc-Flash Detection Fiber-Optic Cables
  • SEL SEL-9331 Power Supply
  • SEL SEL-9322 15 VDC Power Supply
  • SEL SEL-9321 Low-Voltage DC Power Supply
  • SEL SEL-LPS Linear Power Supply
  • SEL SEL-RPM Redundant Power Module
  • SEL SEL-7250 Digital Direct-Replacement Assemblies
  • SEL SEL-2533 Annunciator
  • SEL SEL-2523 Annunciator Panel
  • SEL SEL-2522 Alarm Panel
  • SEL SEL-2516 Rack-Mount Remote I/O Module
  • SEL SEL-2515 Remote I/O Module
  • SEL SEL-2507 High-Speed Remote I/O Module
  • SEL SEL-2506 Rack-Mount Remote I/O Module
  • SEL SEL-2505 Remote I/O Module
  • SEL SEL-3401 Digital Clock
  • SEL SEL-9929 Satellite-Synchronized Clock Display Kit
  • SEL SEL-3405 High-Accuracy IRIG-B Fiber-Optic Transceiver
  • SEL SEL-3400 IRIG-B Distribution Module