KONG -Y
NameDescriptionContent
Location:
product
DS200TCTGG1A Turbine trip valve (TCTG)
❤ Add to collection

DS200TCTGG1A Turbine trip valve (TCTG)

DS200TCTGG1A
U.S.$84921.00
U.S.$67289.00
U.S.$63924.55
U.S.$62578.77
Weight:4.500KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
DS200TCTGG1A

Part Number DS200TCTGG1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark V Function Module Availability In StockDS200TCTGG1A is a Turbine Trip Board (TCTG) developed by GE. It controls the fuel shutoff halves for the turbine and is located in position 4 of the core. On the TCTG board, there are two different trip relay types available for failsafe fuel valve functioning. Primary trip relays (PTRs) and emergency trip relays are both available (ETRs). The PTRs are controlled by the CSP and communication errors. The ETRs are managed by the TCEA boards in the core, and an emergency trip requires a 2/3 vote. Pushbuttons for hardwiring trips will turn off the 24 V dc power to the PTR and ETR relays and start a trip. The TCTG board also houses the synchronizing relays. DS200TCTGG1A Configuration Hardware On the TCTG board, there is only one hardware jumper. The Emergency Overspeed servo Clamp is J1. Activate the jumper to open servo valves 1-4. Applying 24 V dc to the servo outputs requires the usage of this jumper. On the TCQC board is where the actual relay is situated. Software The TCTG board is not configured with any software. DS200TCTGG1A Connectors J7W - The TCPD board's 125 V dc power is distributed throughout the core by J7W. JDR - JDR relays K10, 13, 16, and 19 after reading the PTR trip signals from the TCQA board in the core. reads synchronization orders from the core's TCQA board. reads the PTBA board's bus and generator signals. On the TCTG board, JDR, JDS, and JDT are all daisy-chained together. JDS - Relays K11, 14, 17, and 20 and reads the PTR trip signals from the TCQA board in the core. reads synchronization orders from the core's TCQA board. reads the PTBA board's bus and generator signals. On the TCTG board, JDR, JDS, and JDT are all daisy-chained together. JDT - Relays K12, 15, 18, and 21 when reading the PTR trip signals from the TCQA board in the core. reads synchronization orders from the core's TCQA board. reads the PTBA board's bus and generator signals. On the TCTG board, JDR, JDS, and JDT are all daisy-chained together. JLX - Reads the core-based ETR trip signals. JLX connector feeds K5 and K8 of the ETR relays. the 24 V dc protected bus with energy. JLY - Reads the core's ETR trip signals using JLY. The JLY connector provides power to the ETR relays K4 and K7. the 24 V dc protected bus with energy. JLZ - Reads the ETR trip signals from the P1 core's Z through JLZ. JLZ connector feeds K6 and K9 of the ETR relays. the 24 V dc protected bus with energy. JN - Reads and writes signals to the P1 core's PTBA terminal board. The breaker close signal, hardwire trip signals, and the alarm horn signal are some examples of these signals. JM - Reads and writes signals to the P1 core's PTBA terminal board. The emergency trip signal and the breaker close signal are examples of these signals. JT - Not commonly used. ETR Relay The trip signals for the ETR relays are produced by the TCEA boards X, Y, and Z in the P1 core. The signals are written to the TCTG board through the JLX/Y/Z connections. To decide whether the unit should be tripped, the ETR relays conduct a hardware level two-out-of-three vote. By opening and closing a string of associated contacts on the TCTG board, the device trips if two out of the three relays call for a trip. High-pressure shaft Overspeed and rapid deceleration, low-pressure shaft Overspeed and rapid deceleration, and cross trip are signals that will trip the ETR relays. The JM connector is then used to write the trip signals to the PTBA terminal board. Generator Breaker Close Circuit The STCA board in R1 and the TCEA boards in the P1 core are where the signals to close the generator breaker come from. The TCEA boards use the PT signals from the PTBA terminal board to do the automatic synchronization computations and to deliver the permission signal to close the breaker. The STCA board in the R1 core simultaneously calculates a synchronizing permissive (synch check) and transmits a permissive to close the breaker. The TCTG board votes in favor of the automated synchronized signals by a margin of two to three. If R1 has provided the synch check signal and two out of the three automatic synch signals have been received, the TCTG board will let the breaker be closed. DS200TCTGG1A Manual And External Trip Circuit To start a trip when the contacts are opened, normally closed contact inputs can be plugged into the PTBA terminal board. Examples of these include emergency stop buttons. The K22, 23, 24, and 25 relays are tripped by these signals, which are read by the JN connection and written to the TCTG board. In relation to an ANSI standard device number for the Master Protective, these relays are referred to as the4. The PTR and ETR relay trip when the 4 are tripped because they are connected to a 24 V dc protection bus, which is de-energized when the 4. The TCEA board normally records the event back to the Control Engine and monitors the hardwire trip signals 1 through 3 for an emergency halt. DS200TCTGG1A Features There are 21 plug-in relays in it. Additionally, it features two 12-pin connectors and three 50-pin connectors. The 50-pin connections have the IDs JLY, JLX, and JLZ allocated to them. The 12-pin connectors have the IDs JN and JM allocated to them. The board's 21 relays are delicate and need to be treated with extra care. Due to their electromechanical construction, relays are susceptible to damage. The board may also be harmed by static buildup. The 50-pin connectors are connected with ribbon cables. There are several 50-pin connectors, therefore when you replace the board, you run the risk of connecting the 50-pin connectors improperly. The inadequate installation will increase the amount of time the drive is offline and may also raise the downtime for other equipment nearby. Before removing the drive, turn off the power to it and check the way the wires are attached to the board to prevent any delays. The 21 plug-in relays' IDs begin with a K prefix and terminate with a number. The numbers are listed in order, starting with 1. K1, K5, K10, and K21 are just a few of the IDs.GT TMR/SIMPLEX TRIP

IC697MDL740

IC670PBI001

IC698CHS117C

DS200TCQAG1BHF

IS200AEPCH1ABC

IC697MDL250

IC697MDL250

760-P1-G1-S1-LO-A20-R

SR489-P5-LO-A20-E

IC670CHS001E

IC697MDL653

IS200VTCCH1CBB


  • 81EU50 83SR50 88TK50 Universal I/O and control modules 丨ABB
  • GJR2390200R1411 83SR04R1411 Control Module Universal
  • ABB INSUMMCU2 MCU2A02V24 INSUM® PROFIBUS Gateway Manual SW 2.1
  • ABB REF542 series 1VCR007346 G0028 Function and configuration
  • ABB 216AB61 HESG324013R101 Control Panel-Specifications
  • ABB 216EA61B HESG448230R1/G
  • 216VC62A HESG324442R112/F 丨ABB
  • 500PSM03A 1MRB150038R1 series丨ABB Power control panel
  • REG216, CompactREC216 Numerical Generator ProtectionNumerical Control Unit
  • ABB Panel 800 series 3BSE092980R1 PP886 Standard Panel 15"
  • 500CIM05 1MRB150077R1/B ABB
  • 500CPU05 1MRB150081R1/E ABB-Module
  • 500SCM01 1MRB200059/C 1MRB15004R0001丨ABB Star coupler module
  • ABB SYNCHROTACT ® 5
  • ABB 3BHB006716R0277 SYN 5302a-Z,V277: Auto dual channel Syn
  • ABB Pressductor-PillowBlock Load cells series PFCL201
  • ABB UNS4684A-P,V.1 HIEE305114R00R0001 control panel
  • Tension Electronics PFEA 111, 112, 122 and 113 丨ABB
  • ABB PFRL101C-1.0KN 3BSE023316R1002 Web Tension Measurement
  • 1VCF750090804 HMI SUE 3000 (110...220 V) ABB
  • 57120001-AT DSAO 110 ABB
  • S100 I/O Modules DSAO 120 57120001-EY 丨ABB
  • Advant Controller 500 series 500BIO01 1MRB150005R0001 1MRB200060/E ABB
  • 3BHE023784R2530 PP D113 B01-25-111000: AC 800PEC Static Excitation Systems›UNITROL 6000 X-power
  • ABB EXC3BSE008105R1 SC560 Exchange
  • HR Series Turbine control systems SD Series remote I/O ABB
  • HR Series (Harmony Rack) I/O RSPASI23
  • ABB SPBRC400 Controller with Expanded Memory
  • E3HAB8101-18 Modules Drive System 丨ABB
  • ABB 3BHL000986P7000 LXN 1604-6, 27V 500W
  • ABB REF615_series_ Feeder protection and control
  • ACS 6000 series Medium voltage AC drives for control of 3–27 MW motors up to 3.3 kV
  • I/O Systems - S800 I/O series-ABB
  • SPAJ 140 C Series ABB
  • INCLUDING PFSK 113 7625013-S 丨ABB
  • AC 800PEC The high-performance control system for model-based design
  • HKQCS PARTS ON LINE 129740-002 ABB
  • UNITROL 6000 X-power 3BH022294R0103 GFD233A103
  • AO810 AO810V2 - ABB Ability™ System 800xA® hardware
  • Elastimold® molded vacuum reclosers – MVR MVR 0.44-10KA
  • AC 800M series PM865 3BSE030193R1 discontinued products
  • 1MRK000838-HA ABB RXIDK 2H series
  • ABB 605 series
  • Feeder protection REJ601 BD446NN1XG
  • ABB SAFT183VMC expansion module board unit specifications
  • 3BHB004661R0101 KU C711 AE; GATE UNIT POWER S GUSP
  • PRC3BSE066490R1 PM856AK01 Processor Unit
  • SM560-S (1SAP280000R0001) AC500 CPU Firmware SM560-S-FD-4
  • 769137 Detector 13CO2 10% (Uras26) ABB control unit
  • AC500 CPU Firmware
  • 0002-07-2-00001-01 BMXS Science Module (ADC)
  • Safety instructions for AC500 PLCs 3ADR025003M9903
  • ABB I/O Systems - S800 I/O AI830A
  • AC500-eCo PM556-TP-ETH; PLC-eCo CPU PM556-TP-ETH 3ABD00034186
  • ABB I/O Remote Unit ICSF08D1 CS31 CS 31 Procontic FPR3323101R1012-L
  • WMDOLT2-A75(65KA)6E 1TGE106812P0001 System circuit breaker Drawer type
  • Technical analysis of ABB 1MRK002247-Apr04 protection relay module
  • PFTL101A 0.5KN 3BSE004160R1 Pressductor PillowBlock horizontal load cell
  • 3BSE004166R1 PFTL 101A-1.0kN, Load cell
  • SD Series I/O Interface cRBX01 2VAA008424R1
  • ABB 3BSC950193R1 TB850 CEX-Bus Terminator
  • LDGRB-01 3BSE013177R1 Analysis of module technology
  • GRBTU 3BSE013175R1 Communication gateway module
  • 3BHE037864R0101P UF C911 B101: CVMI2B -PROGRAMMED-
  • Panel 800 version 6
  • 3BHE024577R0101 PPC907BE ACS 2000 Drive Manuals
  • I/O Systems - 3BSE028602R1 DO880 - ABB Ability™ System
  • ABB YPP110A 3ASD573001A1 application controller
  • 57520001-FY DSCS 150 GCOM Communication Unit
  • AC 800M - Processor Modules 3BSE018157R1 PM861AK01 Processor Unit
  • 3BSE069274R1 PP877K Key Panel 10.4" Panel 800
  • 3BSE069449R1 (CI854BK01) PROFIBUS DP-V1
  • 3BSE018135R3 CI858 ABB Ability System 800xA
  • P3BSE042238R1 PANEL 800-PP846 PRE-OWNED
  • ABB NDBU-95 NDBU - DDCS branching unit
  • X10-14210201 605-A53842-002 Abaco Systems specification
  • HIMax®System Bus Module X-SB01 Manual
  • GE Intelligent PlatformsVersaMax* PLC User Manual 151X1235DB15SA03
  • MOTOROLA FLN3524/FCN6650 adapter power supply
  • SYMAP ECG Ship Monitoring And Control Panel 12-36V DC
  • 9200 and 74712 Seismoprobe Velocity Transducers
  • 3500/91 EGD Communication Gateway Module 161204-01
  • 1900/55 Fan Monitor: Operation Manual
  • 3701/55 ADAPT (ESD) Emergency Shutdown Device 323174-01
  • 3300 XL 8 mmProximity Transducer System 330104-00-05-10-02-CN
  • MR series (Melody rack) input and output›CAC 10-P 3BDH000610R1
  • 57160001-ADF DSDP 170 inc. Pos. and Speed meas.
  • S100 I/O - Modules DSDO 115K12 Digital Outp, 32 ch, 24
  • AC 400 Power SA168K16 Basic Power Supply and Switch
  • 3BSE018290R1 DSAI 133A Analog Input Board 32 Channels
  • 3BSE011180R1 Advant Controller 450 Version 2.3 PM511V08 Processor Module
  • 3BSC950164R30 S100 I/O Cables DSTK 221L3 Cable Assembly ,Ribbon Cable,
  • 3BSE020419R1 S100 I/O - Modules DSAO 120AK01 Analog Output 8 ch 12 Bit,
  • REF3BSE012545R1 CI546 VIP Communication Interface
  • 3BSE004772R1 Advant Controller 410 Version 1.5 Communication Modules
  • AC 400 - Communication Modules 3BSE018283R1 CI522A
  • Bently Nevada 3500/05-01-03-00-00-00 Rack Module
  • 3500 Series Status System Bently Nevada 135473-01 Vibration Monitoring Module
  • 330130-045-00-00 Bently Nevada 3300 XL Extension Cable
  • Bently Nevada 330100-90-01 3300 XL 8 mmProximity Transducer System
  • Bently Nevada 149369-01 Key components of 3500 mechanical protection system
  • 106M1081-01 Universal AC Power Input Module Description
  • PR6423 8mm Eddy Current Sensor
  • PR6424 16mm Eddy Current Sensor
  • VIBRO-METER 200-560-000-112 Communication board
  • VIBRO-METER 200-510-111-035 Mechanical protection card
  • Bently Nevada 22810-01-05-50-02 Stop production status confirmation
  • 330180-91-05 Bently Nevada 5/8 mm Proximitor Sensor
  • HIEE300690R0001 AR C093 AE01 Relay Output Card
  • Multilin UR Family Proven, State-of-the-Art Protection & Control Systems
  • Multilin 8 Series Innovative protection and control relay platform
  • Multilin 3 Series Intuitive industrial and utility protective relays for feeders, motors and transformers
  • MVME177P TM Single-Board Computer MOTOROLA
  • ABB DRIVE SERVICES Spare Parts Service product description
  • Cradlepoint IBR200 Product life cycle announcement
  • CC PUIO3 series Honeywell CC-PAOH01 analog output module
  • Honeywell TC-OAV081 Analog output module p/n 97062778
  • Honeywell TC-PRR021 Redundant module DHL, UPS fast delivery
  • Honeywell TC-FXX102 TC-FX10210 controller
  • Honeywell TK-PRS021 C200 Product overview
  • Honeywell ML6420A3007-E master controller
  • Parts on HONEYWELL automaton S4560M S4560M1036 boiler-Diesel boiler
  • Honeywell PK 81181 Installation Instructions for the
  • Honeywell 2MLR-CPUH/F-CC MasterLogic-200 Specifications and Technical Data
  • 3BSE018161R1 PM864AK01 Processor Unit ABB
  • ABB 3BHE017628R0102 PPD115A102 club.
  • FANUC WHEDCO 78004655 System controller module
  • FANUC WHEDCO 78004661 Analysis I/O module