KONG -Y
NameDescriptionContent
Location:
product
DS200TCTGG1A Turbine trip valve (TCTG)
❤ Add to collection

DS200TCTGG1A Turbine trip valve (TCTG)

DS200TCTGG1A
U.S.$84921.00
U.S.$67289.00
U.S.$63924.55
U.S.$62578.77
Weight:4.500KG
Quantity:
(Inventory: 3)
Buy now
Add to cart
Description
DS200TCTGG1A

Part Number DS200TCTGG1A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark V Function Module Availability In StockDS200TCTGG1A is a Turbine Trip Board (TCTG) developed by GE. It controls the fuel shutoff halves for the turbine and is located in position 4 of the core. On the TCTG board, there are two different trip relay types available for failsafe fuel valve functioning. Primary trip relays (PTRs) and emergency trip relays are both available (ETRs). The PTRs are controlled by the CSP and communication errors. The ETRs are managed by the TCEA boards in the core, and an emergency trip requires a 2/3 vote. Pushbuttons for hardwiring trips will turn off the 24 V dc power to the PTR and ETR relays and start a trip. The TCTG board also houses the synchronizing relays. DS200TCTGG1A Configuration Hardware On the TCTG board, there is only one hardware jumper. The Emergency Overspeed servo Clamp is J1. Activate the jumper to open servo valves 1-4. Applying 24 V dc to the servo outputs requires the usage of this jumper. On the TCQC board is where the actual relay is situated. Software The TCTG board is not configured with any software. DS200TCTGG1A Connectors J7W - The TCPD board's 125 V dc power is distributed throughout the core by J7W. JDR - JDR relays K10, 13, 16, and 19 after reading the PTR trip signals from the TCQA board in the core. reads synchronization orders from the core's TCQA board. reads the PTBA board's bus and generator signals. On the TCTG board, JDR, JDS, and JDT are all daisy-chained together. JDS - Relays K11, 14, 17, and 20 and reads the PTR trip signals from the TCQA board in the core. reads synchronization orders from the core's TCQA board. reads the PTBA board's bus and generator signals. On the TCTG board, JDR, JDS, and JDT are all daisy-chained together. JDT - Relays K12, 15, 18, and 21 when reading the PTR trip signals from the TCQA board in the core. reads synchronization orders from the core's TCQA board. reads the PTBA board's bus and generator signals. On the TCTG board, JDR, JDS, and JDT are all daisy-chained together. JLX - Reads the core-based ETR trip signals. JLX connector feeds K5 and K8 of the ETR relays. the 24 V dc protected bus with energy. JLY - Reads the core's ETR trip signals using JLY. The JLY connector provides power to the ETR relays K4 and K7. the 24 V dc protected bus with energy. JLZ - Reads the ETR trip signals from the P1 core's Z through JLZ. JLZ connector feeds K6 and K9 of the ETR relays. the 24 V dc protected bus with energy. JN - Reads and writes signals to the P1 core's PTBA terminal board. The breaker close signal, hardwire trip signals, and the alarm horn signal are some examples of these signals. JM - Reads and writes signals to the P1 core's PTBA terminal board. The emergency trip signal and the breaker close signal are examples of these signals. JT - Not commonly used. ETR Relay The trip signals for the ETR relays are produced by the TCEA boards X, Y, and Z in the P1 core. The signals are written to the TCTG board through the JLX/Y/Z connections. To decide whether the unit should be tripped, the ETR relays conduct a hardware level two-out-of-three vote. By opening and closing a string of associated contacts on the TCTG board, the device trips if two out of the three relays call for a trip. High-pressure shaft Overspeed and rapid deceleration, low-pressure shaft Overspeed and rapid deceleration, and cross trip are signals that will trip the ETR relays. The JM connector is then used to write the trip signals to the PTBA terminal board. Generator Breaker Close Circuit The STCA board in R1 and the TCEA boards in the P1 core are where the signals to close the generator breaker come from. The TCEA boards use the PT signals from the PTBA terminal board to do the automatic synchronization computations and to deliver the permission signal to close the breaker. The STCA board in the R1 core simultaneously calculates a synchronizing permissive (synch check) and transmits a permissive to close the breaker. The TCTG board votes in favor of the automated synchronized signals by a margin of two to three. If R1 has provided the synch check signal and two out of the three automatic synch signals have been received, the TCTG board will let the breaker be closed. DS200TCTGG1A Manual And External Trip Circuit To start a trip when the contacts are opened, normally closed contact inputs can be plugged into the PTBA terminal board. Examples of these include emergency stop buttons. The K22, 23, 24, and 25 relays are tripped by these signals, which are read by the JN connection and written to the TCTG board. In relation to an ANSI standard device number for the Master Protective, these relays are referred to as the4. The PTR and ETR relay trip when the 4 are tripped because they are connected to a 24 V dc protection bus, which is de-energized when the 4. The TCEA board normally records the event back to the Control Engine and monitors the hardwire trip signals 1 through 3 for an emergency halt. DS200TCTGG1A Features There are 21 plug-in relays in it. Additionally, it features two 12-pin connectors and three 50-pin connectors. The 50-pin connections have the IDs JLY, JLX, and JLZ allocated to them. The 12-pin connectors have the IDs JN and JM allocated to them. The board's 21 relays are delicate and need to be treated with extra care. Due to their electromechanical construction, relays are susceptible to damage. The board may also be harmed by static buildup. The 50-pin connectors are connected with ribbon cables. There are several 50-pin connectors, therefore when you replace the board, you run the risk of connecting the 50-pin connectors improperly. The inadequate installation will increase the amount of time the drive is offline and may also raise the downtime for other equipment nearby. Before removing the drive, turn off the power to it and check the way the wires are attached to the board to prevent any delays. The 21 plug-in relays' IDs begin with a K prefix and terminate with a number. The numbers are listed in order, starting with 1. K1, K5, K10, and K21 are just a few of the IDs.GT TMR/SIMPLEX TRIP

IC697MDL740

IC670PBI001

IC698CHS117C

DS200TCQAG1BHF

IS200AEPCH1ABC

IC697MDL250

IC697MDL250

760-P1-G1-S1-LO-A20-R

SR489-P5-LO-A20-E

IC670CHS001E

IC697MDL653

IS200VTCCH1CBB


  • MOOG G123-825-001 BUFFER AMPLIFIER
  • Motorola MVME5100 Series VME Processor Modules
  • ABB MEASUREMENT & ANALYTICS NGC8209 Natural gas chromatograph
  • Motorola MVME162 Embedded Controller
  • HIMatrix Safety-Related Controller System Manual for the Modular Systems
  • MOTOROLA MVME2400 Series VME Processor Module
  • Sieger System 57
  • KONGSBERG MRU product line continuation
  • Woodward easYgen-3100/3200 Genset Control for Multiple Unit Operation
  • Woodward MFR 300 Multifunction Relay / Measuring
  • ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers
  • Woodward easYgen-1400 Technical Manual Genset Control
  • Woodward easYgen-400 Operation Manual Genset Control
  • Woodward High Output Digital Valve Positioner (DVP) DVP5000/DVP10000/DVP12000
  • Woodward High Output Digital Valve Positioner DVP5000 and DVP10000
  • Woodward TG611-13/-17 Overspeed Test Device Conversion Kit
  • Woodward MicroNet Safety Module (MSM)
  • Woodward 2301A Electronic Load Sharing and Speed Control 9905/9907 Series
  • Woodward-Service Bulletin 01671
  • UniOP eTOP40B 12.1” TFT color display
  • UniOP eTOP40 TFT Color display
  • UniOP eTOP33B 10.4” TFT color display
  • UniOP eTOP33C eTOP33-0050 Resistive touchscreen
  • UniOP eTOP30. eTOP32 eTOP32-0050 Human-machine interface equipment
  • UniOP eTOP20B and eTOP21B eTOP20B-0050
  • UniOP eTOP12 eTOP12-0050 Advanced human-machine interface equipment
  • UniOP eTOP11 eTOP11-0050 HMI
  • UniOP eTOP06 HMI
  • UniOP eTOP05EB eTOP05EB-DF45 HMI
  • UniOP eTOP05. eTOP05P Human-machine interface equipment
  • UniOP eTOP03 eTOP03-0046
  • UniOP eTOP507 507U2P1 eTOP Series 500 Human-Machine Interface
  • UniOP eTOP307
  • UniOP ePAD32B, ePAD33B and ePAD33BT ePAD33B-0350
  • UniOP ePAD05 and ePAD06
  • UniOP ePAD04 ePAD04-D046 Universal Operator Panel
  • UniOP ePAD03 and ePAD04
  • UniOP CP02F-02, CP02R-04
  • UniOP CP01R-04 Compact Human-Interface Device
  • UniOP ERT-16 - Industrial PLC Workstation
  • UniOP ePAD03 and ePAD04
  • UNIOP EPALM10-DA71 state-of-the-art handheld HMI
  • Watlow SERIES CLS200 SPECIFICATION SHEET
  • Detailed Explanation of B&R Power Panel 300/400: The Core of Industrial Automation Control
  • YOKOGAWA Models ANB10S, ANB10D, ANR10S, ANR10D Node Units (for FIO)
  • Woodward ESDR 4 Current Differential Protection Relay
  • Woodward easYgen-3000 Genset Control for
  • Woodward CPC-II Current-to-Pressure Converter
  • Woodward 8290-189-EPG-installation-manual 8290-044
  • Woodward Product Change Notification 06946A
  • Woodward Product Change Notification 06912
  • Fisher™ 4660 High-Low Pressure Pilot
  • Flexible digital protection and control equipment SYMAP®
  • Woodward 723PLUS Digital Control
  • Woodward 505 Digital Controller For steam turbineses
  • Woodward 85018V2 505E Digital Governor for Extraction Steam Turbines
  • Woodward 85018V1 Turbine Control Parameters
  • Woodward 26871 505 Enhanced Digital Control for Steam Turbines
  • Woodward 03365 505E (Extraction / Admission)
  • KONGSBERG RMP420-Remote Multipurpose Input/Output
  • KONGSBERG RCU501 Remote Controller Unit
  • KONGSBERG RCU500 Remote Controller Unit
  • K-Gauge TOP KONGSBERG Tank Overfill Protection SystemFeatures
  • Kongsberg DPS112 DGNSS (DGPS/DGLONASS) sensor
  • Kongsberg d0000930 presafe-atex-report signed
  • HIMax TECHNICAL FACTS X Series
  • GE Multilin F650
  • GE MIF II - Legacy
  • GE PQM II Power QualIty Meter
  • Hydran 201Ti Mark IV Essential DGA monitoring for transformers
  • alstom AMS42/84 5B Amplifier SystemAmplifier Technology at its Best.
  • GE VMIVME-5576 Fiber-Optic Reflective Memory with Interrupts
  • GE Multilin 750/760 - Legacy Feeder Protection System
  • GE Fanuc Automation VMICPCI-7806 Specifications
  • GE VMIVME-7807 VME-7807RC* Intel® Pentium® M-Based VME SBC
  • GE Fanuc Automation VMIVME-7750 Specifications
  • FOXBORO Compact FBM240. Redundant with Readback, Discrete
  • FOXBORO FBM208/b, Redundant with Readback, 0 to 20 mA I/O Module
  • FOXBORO FBM201e Analog Input (0 to 20 mA) Interface Modules
  • Foxboro DCS FBM206 Pulse Input Module
  • FOXBORO FBM216 HART® Communication Redundant Input Interface Module
  • FOXBORO Z-Module Control Processor 270 (ZCP270)
  • Foxboro DCS Compact FBM241/c/d, Redundant, Discrete I/O Modules
  • Foxboro FBM223 PROFIBUS-DP™ Communication Interface Module
  • Foxboro DCS FBM204. 0 to 20 mAI/OModule
  • Foxboro FBM239, Discrete 16DI/16DO Module
  • Foxboro FBM202 Thermocouple/mV Input Module
  • Foxboro E69F Current-to-Pneumatic Signal Converter
  • EMERSON M-series Intrinsically Safe I/O
  • Configuration for AMS 6500 Protection Monitors
  • EMERSON DeltaV™ M-series Traditional I/O
  • EMERSON DeltaV™ SQ Controller
  • AEROTECH Ndrive MP Hardware Manual
  • AEROTECH Ndrive HPe 10/20/30
  • AEROTECH Ndrive CP Hardware Manual
  • AEROTECH Ndrive Linear Series Digital Servo Amplifiers – Linear
  • AEROTECH Ndrive HP 10/20/30 P/N: EDU170
  • AEROTECH EDU176_Ndrive_HL
  • ADVANCEDMOTION CONTROLS Analog Servo Drive 120A10
  • GE JPAX-H
  • GE JPAX family
  • GE Industry Leading Experience
  • GE Ether-1000 Unit
  • GE Cyber Secured Service Unit
  • GE Lentronics E1MXe Multiplexer
  • GE TTMX Teleprotection Terminal
  • GE Lentronics T1 Multiplexer
  • GE Lentronics JungleMUX SONET Multiplexer
  • GE Lentronics E1MX Multiplexer
  • GE Lentronics TN1Ue SDH Multiplexer
  • GE Lentronics TN1U SDH Multiplexer
  • GE Gridcom DXC Family Access and Transmission Multiplexer
  • GE Advanced Network Management
  • GE Lentronics VistaNET Network Management System (NMS)
  • ABB System Controller Connect
  • Ethernet Module EI 803F ABB
  • ABB Ethernet Modules EI 802F
  • ABB Ethernet Modules EI 801F
  • ABB Power Supply SD 802F / SD 812F
  • ABB Power Supply SA 801F / SA 811F
  • ABB Basic Unit PM 802F /PM 803F
  • Control product - Soft starter PST/PSTB (Intelligent Type) ABB
  • ABB CP450 Installation and Operation Manual
  • ABB ompact 800 5.1 Product Catalog
  • ABB Panel 800 version 6
  • ABB Panel 800 Version 6- Panel Builder Version 6.0-1
  • ABB Control Panels CP405 Control Panels CP408
  • ABB PowerUP for medium voltage drives