Omron NE1A-SCPU02 Network Controller
Omron NE1A-SCPU02 Network Controller
Specifications
Product Life Cycle Discontinuation Announced
Number of I/O 40 Safety Inputs & 8 Safety Outputs
Power Supply 24 VDC

The indication accuracy of K thermocouples in the −200 to 1.300°C range, T and N thermocouples at a temperature of −100°C max., and U
and L thermocouples at any temperature is ±2°C ±1 digit max. The indication accuracy of B thermocouples at a temperature of 400°C max. is
not specified. The indication accuracy of B thermocouples at a temperature of 400 to 800°C is ±3°C max.
The indication accuracy of R and S thermocouples at a temperature of 200°C max. is ±3°C ±1 digit max. The indication accuracy of C/W
thermocouples is (±0.3% of PV or ±3°C, whichever is greater) ±1 digit max.
The indication accuracy of PLII thermocouples is (±0.3% of PV or ±2°C, whichever is greater) ±1 digit max.
*2.However, the precision between 0 and 4 mA for a 0 to 20 mA output is ±1% FS max.
*3.Ambient temperature: −10°C to 23°C to 55°C, Voltage range: −15% to 10% of rated voltage
*4.K thermocouple at −100°C max.: ±10°C max.
*5.The unit is determined by the setting of the Integral/Derivative Time Unit parameter.
*6.External serial communications (RS-485) and USB-Serial Conversion Cable communications can be used at the same time.
*7.Refer to your OMRON website for the most recent information on applicable models.
*8.Refer to information on maritime standards in Shipping Standards on page124 for compliance with Lloyd's Standards.
*9.Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)
Main unit: Approx. 80 g, Models with Screw Terminal Unit: Approx. 40 g,
Models with Push-In Plus Terminal Unit: Approx. 40 g
Degree of protection Main unit: IP20. Terminal unit: IP00
Memory protection Non-volatile memory (number of writes: 1.000.000 times)
Setup Tool CX-Thermo version 4.6 or higher
Setup Tool port
E5DC/E5DC-B bottom panel: An E58-CIFQ2 USB-Serial Conversion Cable is used to connect a USB port
on the computer. *6
E5DC/E5DC-B front panel: An E58-CIFQ2 USB-Serial Conversion Cable and E58-CIFQ2-E Conversion
Cable are used together to connect a USB port on the computer.*6
Standards Approved standards cULus: UL 61010-1/CSA C22.2 No.61010-1. Korean wireless regulations (Radio law: KC Mark) (Some
models only.) *7. Lloyd's standards (E5DC only) *8. EAC
Conformed standards EN 61010-1 (IEC 61010-1), RCM
EMC
EMI: EN61326-1 *9
Radiated Interference Electromagnetic Field Strength: EN55011 Group 1. class A
Noise Terminal Voltage: EN55011 Group 1. class A
EMS: EN61326-1 *9
ESD Immunity: EN61000-4-2
Electromagnetic Field Immunity: EN61000-4-3
Burst Noise Immunity: EN61000-4-4
Conducted Disturbance Immunity: EN61000-4-6
Surge Immunity: EN61000-4-5
Voltage Dip/Interrupting Immunity: EN61000-4-11
| 330105-02-12-15-02-05 Bently Nevada 3300 XL 8 mm Proximity Probes |
| 330500-01-05 Bently Nevada Velomitor Piezo-velocity Sensor |
| 3500/40M-01-02 Proximitor Monitor Bently Nevada |
| 3500/40M-01-01 Proximitor Monitor Bently Nevada |
| 3500/25-02-01-01 Enhanced Keyphasor Module BENTLY NEVADA |
| 3500/32-01-01 BENTLY NEVADA 3500 4-Channel Relay Module |
| 3500/92-04-01-05 The 3500/92 Communication Gateway Bently Nevada |
| 3500/33-SIL2-03-05 Relay Module Bently Nevada |
| 3500/61-SIL2-01-05 Bently Nevada Temperature Monitor |
| 3500/42M-SIL2-09-05 Proximitor Seismic Monitor BENTLY NEVADA |
| 3500/05-01-03-05-00-01 system rack manufactured Bently Nevada |
| 1746-A13 Allen-Bradley SLC500 chassis |
| 1746-NR4 Allen-Bradley SLC 500 RTD/Resistance Analog Input Module |
| 1746-NI8I SM331 SLC 500 Analog I/O Module Allen Bradley |
| 16710-30 Bently Nevada 16710 Interconnect Cables |
| User name | Member Level | Quantity | Specification | Purchase Date |
|---|
Add: High-tech Software Park, Xiamen City, Fujian Province
Mobile: +86-17750019513(WhatsApp)
Email: yy4291644@gmail.com
Website: https://www.abb-sis.com