KONG -Y
NameDescriptionContent
Location:

ABB AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers

From:ABB | Author:kongjiang | Time :2026-03-06 | 981 Browse: | 🔊 Click to read aloud ❚❚ | Share:

AX410. AX411. AX416. AX450 and AX455

Single and dual input analyzers

for low level conductivity

The AX400 series

The AX400 analyzers incorporate the latest technology to

provide highly reliable, flexible, feature-packed devices that

satisfy a diverse range of process monitoring and control

applications. The complete range encompasses solutions for

pH/Redox (ORP), conductivity and dissolved oxygen.

Models AX41x and AX45x enable continuous measurements

of one or two low-level conductivity points with simultaneous

local display and retransmission. The analyzers are used with

ABB 2-electrode conductivity cells providing measurements

with exceptional accuracy and performance.

Model AX45x analyzers are dedicated to United States

Pharmacopoeia <645>.

AX400 Series analyzers are available for either wall-/pipe- or

panel-mounting and are rated to IP65.

High functionality as standard

All versions are supplied with two fully-isolated current

outputs as standard, that can be assigned to the measured

parameter, the sample temperature or any appropriate

calculated variables.

Three programmable relay set points are available that can

also be assigned as required.

Innovative features such as a power saving display and a

diagnostic current output option all contribute to low cost of

ownership

Plug-and-produce expanded control

An advanced function card provides an additional two current

outputs and two further alarm relays that can be assigned to

either measured values or sample temperature.

ABB plug-and-produce software automatically reconfigures

the analyzer if an option board is added later. No user

programming is necessary.

A real-time clock and logbook are also included, making the

full-facility versions extremely powerful and versatile.

Significantly reduced

maintenance costs

The AX400 analyzers are supplied as standard for 85 to

265 V AC operation. There are no inner switches to set.

They can also be provided for 24 V AC or 12 to 30 V DC supply

and recognize automatically which of the two supplies is

being used. 24 V DC operation reduces maintenance costs

significantly by negating the need for costly, yearly safety

tests to ensure compliance with safety procedures.

Energy saving display

The backlit display has been designed to operate in all types

of environments and shows both the measured parameter(s)

and, on a separate 16-character display line, diagnostic and

computed information.

On dual-input analyzers both measured parameters are

displayed simultaneously.

For conservation of energy, the backlight can be set to switch

off automatically after 60 s of inactivity.

Easy access installation terminals

Easy access to the terminations ensures rapid and cost

effective installation. The wall-/pipe-mount version has been

designed to ensure that cable connection is simple and

convenient. Ingress protection of the electronics section is

retained even when the terminal compartment is opened.

Single and dual input analyzers

Both single and dual-input analyzers provide accurate

measurement of low-level conductivity and can be configured

for ranges in µS cm–1. µS m–1. mS cm–1 and mS m–1.

Alternatively, the instrument can be set up for resistivity in

MW-cm, total dissolved solids and salinity.

In addition, the dual-input analyzer calculates, displays and

transmits:

• Ratio of cell 1 / cell 2

• Difference cell 1 – cell 2

• % Passage (cell 1 / cell 2) x 100

• % Rejection (1 – [cell 1 / cell 2]) x 100

• Inferred pH

These facilities are invaluable tools for demineralization and

reverse osmosis and a host of industrial processes.

Easy access installation terminals

Easy access to the terminations ensures rapid and cost

effective installation. The wall-/pipe-mount version has been

designed to ensure that cable connection is simple and

convenient. Ingress protection of the electronics section is

retained even when the terminal compartment is opened.

Cation conductivity and

inferred pH measurement

In low conductivity, ammoniated boiler waters, the AX411

analyzer can calculate an inferred pH measurement from the

conductivity and a preset ammonia concentration. With this

method, one AX411 provides cation conductivity, a direct

output of pH, reduced cost and none of the maintenance

associated with pH electrodes.

Self-monitoring of the validity of the pH measurement is

achieved by checking that an after-cation conductivity value

is sufficiently low. This measurement is provided by the

second input of the AX411 analyzer. Alarm contacts can be

configured for cation conductivity, invalid pH and exhausted

resin

AX410 integral P, PI and PID control

The single input AX410 analyzers incorporate three-term PID

Control offering three modes of sophisticated control:

analog, pulse length (time proportional) and pulse frequency.

These are supplied as standard and can be operated in direct-

or reverse-acting mode, depending upon the application.

Comprehensive temperature

compensations

AX41x and AX45x conductivity analyzers provide true

temperature compensation for all high-purity water

applications:

• Raw (uncompensated) conductivity– USP<645> water for injection and purified water

• NaCl– General monitoring– Mixed-bed exchanger– Final polisher effluent– Cation exchanger inlet– Anion exchanger effluent– Reverse osmosis

  • SHINKAWA MODEL VM-5Z5,6,7  POWER SUPPLY UNIT
  • SHINKAWA MODEL VM-5Y1,2,3 RELAY MODULE UNIT
  • SHINKAWA MODEL VM-5P3 PHASE MARKER UNIT
  • SHINKAWA MODEL VM-53 DUAL COMMUNICATION UNIT
  • SHINKAWA MODEL VM-52 BOTTOM HOLD MONITOR
  • SHINKAWA MODEL VM-51 ROD DROP MONITOR
  • SHINKAWA MODEL VM-5R TACHOMETER
  • SHINKAWA MODEL VM-5S DUAL TACHOMETER
  • SHINKAWA MODEL VM-5A DUAL VALVE
  • SHINKAWA MODEL VM-5E DUAL CASE
  • SHINKAWA MODEL VM-5L COMPLEMENTARY INPUT
  • SHINKAWA MODEL VM-5N RAMP DIFFERENTIAL
  • SHINKAWA MODEL VM-5D DUAL DIFFERENTIAL
  • SHINKAWA MODEL VM-5T DUAL THRUST MONITOR
  • SHINKAWA MODEL VM-5C ECCENTRICITY MONITOR
  • SHINKAWA MODEL VM-5C ECCENTRICITY MONITOR
  • SHINKAWA MODEL VM-5M DUAL PATH MONITOR
  • SHINKAWA MODEL VM-5B DUAL ACCELERATION MONITOR
  • SHINKAWA MODEL VM-5B DUAL ACCELERATION MONITOR
  • SHINKAWA MODEL VM-5U DUAL SEISMIC MONITOR
  • SHINKAWA MODEL VM-55 VIBRATION MONITOR
  • SHINKAWA VM-742B1-5 VIBRATION MONITORING SYSTEM CARD
  • Shinkawa PSP-17B P-24-64A P-24-64B Circuit Board Module
  • SHINKAWA MGP-67 PCB
  • Shinkawa JBP-278 P-22-48A-1 P-22-48B-1 Circuit Board Module
  • Shinkawa VM-721B 18-CHANNEL RELAY MODULE
  • Shinkawa FRP-337 P-26-54A P-26-54B Circuit Board Module
  • Shinkawa WKN-142K2-2 Vibration Transmitter
  • SHINKAWA VL-202A08L-1012 Rotor Position Monitor Probe Sensor
  • Shinkawa CPP-128 P-26-74A P-26-74B Circuit Board Module
  • Honeywell 51402755-100 PROCESSOR CARD
  • Honeywell 51107595-100 Power
  • HONEYWELL 51304544-100 Control Board
  • HONEYWELL 51109919-100 BOARD
  • HHoneywell 51204160-175 Digital Input Module
  • Honeywell 51304754-150 High Level Analog Input Module
  • HONEYWELL 51304690-100 DIGITAL INPUT CARD
  • Honeywell 51401635-150  COMM CONTROL
  • HONEYWELL 51204174-175 MC-TAOY 52 ANALOG OUTPUT BOARD
  • HONEYWELL  51400596-100
  • HONEYWELL 51401291-100 board card
  • HONEYWELL 51401642-150 I/O LINK MODULE
  • Honeywell LCN‑E Hub Power Supply 38500148‑300
  • Honeywell LCN‑E Hub redundant 38500143‑202 Twisted‑pair LCN
  • Honeywell LCN‑E Hub non‑redundant,38500143‑102
  • Honeywell Enhanced Micro‑TDC‑3000 System Unit MX‑DTAC01K2
  • Honeywell Enhanced Micro‑TDC‑3000 System Unit MX‑DTAB01K2
  • Honeywell Enhanced Micro‑TDC‑3000 System Unit MT11‑520
  • Honeywell STI‑CE Smart Transmitter Interface 51304516‑150
  • Honeywell STI Smart Transmitter Interface 51304516‑100 MC‑PSTX02
  • Honeywell ulse Counter IOP 51304386‑100 MU‑PPIX02
  • Honeywell DO Digital Output IOP‑CE 51304487‑150 CE  version
  • Honeywell DO Digital Output IOP  51304487‑100 MC‑PDOX02
  • Honeywell TDC‑3000 SOE DI IOP,51402625-175 MC‑PDIS12
  • Honeywell TDC‑3000  DI Digital Input IOP‑CE 51304485‑150
  • Honeywell TDC‑3000 DI Digital Input IOP 51304485‑100 MC‑PDIX02
  • Honeywell TDC‑3000 AO Analog Output IOP 51304757‑100 MU‑PAOX02
  • Honeywell TDC‑3000  TC Thermocouple IOP 51304756‑100 MU‑TAMT03
  • Honeywell TDC‑3000   51304755‑100 MU‑TAMR03
  • Honeywell TDC‑3000 LLAI Multiplex AI IOP,51304362‑150
  • Honeywell TDC‑3000  HLAI Analog Input IOP‑CE, 51304363‑150
  • Honeywell TDC‑3000  HLAI Analog Input IOP,51304363‑100.4‑20mA
  • Honeywell TDC‑3000  HPM Power Supply,51401731‑100
  • Honeywell TDC‑3000 Standard 1986.HPM High‑Performance PM CPU,51402362‑100
  • Honeywell TDC‑3000 APM Advanced Process Manager CPU,51304459‑100
  • Honeywell TDC‑3000 Standard 1986.PM Process Manager CPU,51304362‑100
  • Honeywell TDC‑3000 NIM Network Interface Module,51304481‑200
  • Honeywell TDC‑3000 NIM Network Interface Module 51304481‑100
  • Honeywell TDC‑3000 BASIC,LCN Terminator Resistor,30732052‑001.Coaxial
  • Honeywell TDC‑3000 BASIC,Hiway Coupler,30753732‑001
  • Honeywell TDC‑3000 BASIC,LEPIU Low‑Energy PIU,4DP7APCFA309
  • Honeywell TDC‑3000 BASIC,HLPIU High‑Level PIU,4DP7APCFA106
  • Honeywell TDC‑3000 BASIC,Multifunction Controller(TDC‑2000 DHW),4DP7MFA103
  • Honeywell TDC‑3000 BASIC,Extended Controller(TDC‑2000 DHW),4DP7AXA102
  • Honeywell TDC‑3000 BASIC,Basic Controller(TDC‑2000 DHW),4DP7BBA101
  • Honeywell 51305508‑100 TDC‑3000 BASIC,XLCNE2 LCN Extender
  • Honeywell TDC‑3000 BASIC,E‑PLCG PLC Gateway,51400997‑200
  • Honeywell TDC‑3000 BASIC,PLNM Plant Network Module,51401163‑100
  • Honeywell TDC‑3000 BASIC,CG Computer Gateway,80360206‑001
  • Honeywell TDC‑3000 BASIC,HG High‑Speed Gateway,51304526‑100
  • Honeywell TDC‑3000 BASIC,HM History Module,51191596‑200
  • Honeywell TDC‑3000 BASIC,HM History Module,51191596‑100
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑800.K2LCN‑8
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑600.K2LCN‑6
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑400,K2LCN‑4
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑300.K2LCN‑3
  • Honeywell TDC‑3000 BASIC,AM Application Module CPU,51401551‑200,K2LCN‑2
  • Honeywell TDC‑3000 BASIC,US Universal Station CPU,51401288‑200
  • Honeywell TDC‑3000 BASIC,US Universal Station CPU,51401288‑100
  • SHINKAWA VM-21P1 Signal Conditioner 0-50MM 24VDC
  • Shinkawa RiverNew Vibration Transducer VK202 Series
  • Shinkawa Electric VM-3E2 Vibration Monitor Module
  • Shinkawa JBP-47 P-22-48A-1 / P-22-48B-1 Circuit Board Module
  • Shinkawa MODEL VM-5K DUAL VIBRATION MONITOR
  • Shinkawa CMU-15A (CMU15A) Industrial Camera Controller
  • Shinkawa CMU-13A CMU13A Industrial Camera Controller
  • Shinkawa EFU-10 (EFU10) Spark Generator Unit
  • Shinkawa UTC-1000 ZUP-02C Board
  • Shinkawa MDP-89 MDP89 P-24-674A P-24-674B Circuit Board Module
  • Shinkawa CB-1011005001 Signal Cable Assembly
  • SHINKAWA VL-202A08L-1002 Sensor VL-08020L01 Probe Cable F84N1695
  • Shinkawa VK-202A2 Driver & VL-202A08L-1A72 Proximity Sensor Probe
  • SHINKAWA VM-703B VIBRATION MONITORING SYSTEM CARD 2R05-002-P001C
  • Shinkawa BH-150-03 Signal Conditioner / Preamplifier Unit
  • Shinkawa BH-150 Signal Conditioner / Preamplifier Unit
  • Shinkawa Electric VM-3D2 Thrust Monitor Module
  • Shinkawa LCU-37 Monitoring module
  • Shinkawa LCU-44B-06 Local Control Unit Module
  • ABB 3BHE039724R2643 PPD513 high-performance programmable controller module
  • Samsung SSAS21-RTD Resistance Temperature Detector Input Module
  • Samsung SSAS21-AI Analog Input Module
  • Samsung SSAS21-DO Digital Output Module
  • Samsung SSAS21-DI Digital Input Module
  • Samsung SSAS21-CPU Central Processing Unit Module
  • Samsung SMTB-RTD RTD/TC Terminal Board
  • Samsung SMTB-AI Analog Input/Output Terminal Board
  • Samsung SMTB-DO Digital Output Terminal Board
  • Samsung SMTB-DI Digital Input Terminal Board
  • SAMSUNG SMBK-12 IOU Rack Backplane
  • SAMSUNG SMBK-08 IOU Rack Backplane
  • SAMSUNG SMPS-08 Rack Power Module
  • SAMSUNG SMCOM-08 Communication Expansion Card
  • SAMSUNG SMPI-8 Pulse Count Input Module
  • SAMSUNG SMTC-8 Thermocouple Input Module
  • SAMSUNG SMAOC-12 Analog Output Module (12CH)
  • SAMSUNG SMAOC-8 Analog Output Module (8CH)
  • SAMSUNG SMAIC-12 Analog Current Input Module (12CH)
  • SAMSUNG SMRTD-8 RTD Pt100 Temperature Input Module (8CH)